Go to page of
Similar user manuals
-
Home Safety Product
Oregon Scientific THGR 238 NF
12 pages 0.16 mb -
Home Safety Product
Oregon Scientific Wireless Outdoor Temperature and Humidity Sensor THGR 238 NF
12 pages 0.17 mb -
Home Safety Product
Oregon Scientific WMR200A
11 pages 8.6 mb -
Home Safety Product
Oregon Scientific THN132N
2 pages 1.15 mb -
Home Safety Product
Oregon Scientific WMR200
11 pages 8.6 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Oregon Scientific WMR200A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Oregon Scientific WMR200A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Oregon Scientific WMR200A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Oregon Scientific WMR200A should contain:
- informations concerning technical data of Oregon Scientific WMR200A
- name of the manufacturer and a year of construction of the Oregon Scientific WMR200A item
- rules of operation, control and maintenance of the Oregon Scientific WMR200A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Oregon Scientific WMR200A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Oregon Scientific WMR200A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Oregon Scientific service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Oregon Scientific WMR200A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Oregon Scientific WMR200A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 EN Professional Weather Center Model: WMR200 / WMR200A USER MANUAL CONTENTS Introduction .............................................................................................................. 1 Packaging Contents ............................................................................................... 1 Ma in Un it .................[...]
-
Page 2
2 EN ASSEMBLY PARTS 1x V ertical Attachment Bracket 1 x Cone-Shaped End 1 x Horizontal Attachment Bracket 1 x Bottom Pole 1 x Mid Pole 1x T op Pole 2 x Round U- bolts 2 x Rectangular Base Legs 3 x Eye pins 1 x V ersatile Base (Wall or Ground Fixable) 4 x screws (T ype A) ACCESSORIES - SENSORS This product can work with up to 10 sensors at any one t[...]
-
Page 3
3 EN 4. Indicates pressure alarm is ON 5. User selectable altitude / pressure measurement unit RAINFALL 1 5 6 7 8 2 3 4 1. 0 (current) to – 24 hours rainfall record / 2. Accumulated total rainfall (refer to SINCE date stamp in clock area for further details) 3. Rain rate indicator 4. Rain reading 5. Sensor batteries low 6. Indicates high rainfall[...]
-
Page 4
4 EN WIND SENSOR 2 3 4 1 1. Wind Direction 2. Wind vane casing 3. Anemometer 4. Solar power socket RAIN GAUGE Base and funnel: 1 2 3 1. Rain Gauge 2. Battery compartment 3. RESET button 1 2 1. Funnel 2. Indicator OUTDOOR TEMPERATURE / HUMIDITY SENSOR 1 2 3 4 1. Temperature / humidity sensor casing 2. Solar power socket 3. RESET button 4. Battery co[...]
-
Page 5
5 EN 4. Insert sensor into the casing, twist and click to the right to secure. 5. Slide temperature and humidity sensor onto the smaller end of the sensor connector. REMOTE UNIT ASSEMBLY 1 3 4 2 1. Insert the cone-shaped end into the pole. 2. Using 2 screws, fix it firmly into place. 3. Insert the versatile plastic base into the pole. Align the h[...]
-
Page 6
6 EN Securing the assembled remote unit: 22 21 21. Insert the 2 rectangular base legs through the holes of the versatile base and hammer down. 22. Using the string, tie a knot on the eye pins. Hammer each eye pin into the ground at a 90° angle. IMPORTANT Using the fasteners, tighten the string. T o tighten, pull fastener down. T o loosen, thread t[...]
-
Page 7
7 EN T o set up the Rain Gauge: 2 1 1. Remove screws and slide the cover off in an upwards motion. 2. Insert the batteries (2 x UM-3 / AA), matching the polarities (+ / -). Press RESET after each battery change. 3 3. Remove the fibre tape. T o ensure a level plane: Put a few drops of water on the cross at the base of the funnel to check the horizo[...]
-
Page 8
8 EN NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. T o enable / disable signal reception: Press and hold Clock area to enable / disable signal reception. A beep will sound to confirm action. NOTE For best reception, the base station should be placed on a flat, non-metallic surface near[...]
-
Page 9
9 EN 4. Press UP / DWN to set the desired values. 5. Press • ALARM to confirm and continue to next setting OR. • touch anywhere on the screen (except tool bar / weather forecast area) to confirm and exit. T o enable / disable alarms: 1. Press desired area to activate. 2. Press ALARM to display set Time and HI / LO alarm. 3. Press ALARM ON/OFF[...]
-
Page 10
10 EN T o view remaining days for records: Press clock area until DA T A LOGGER mode is displayed. NOTE When DA T A LOGGER is full, i.e., no more records can be stored on unit, ‘ DA T A LOGGER ’ and ‘ O Days ’ will flash. T o upload records to PC: Plug USB and upload onto computer . NOTE PC program provided must be installed before uploadi[...]
-
Page 11
1 1 EN Accuracy 25% - 40%: +/- 7% 40% - 80%: +/- 5% 80% - 90%: +/- 7% Comfort 40% to 70% Memory Current, Min and Max Battery 2 x UM-4 (AAA) 1.5V batteries RF TRANSMISSION RF frequency 433MHz Range Up to 100 meters (328 feet) with no obstructions T ransmission Approx. every 60 seconds No. of Channel 1 for Wind/ Rain/ UV and 10 for T emp. / Humidity [...]