Go to page of
Similar user manuals
-
Power Supply
Panasonic HHR370AH
1 pages 0.45 mb -
Power Supply
Panasonic HHR160A
5 pages 0.07 mb -
Power Supply
Panasonic EZAEG3A
2 pages 0.06 mb -
Power Supply
Panasonic IMC80A
62 pages 0.63 mb -
Power Supply
Panasonic A4 Series
1 pages 0.35 mb -
Power Supply
Panasonic LC-P0612P
1 pages 0.06 mb -
Power Supply
Panasonic MDDDT5540P
133 pages 1.34 mb -
Power Supply
Panasonic CGR18650AF
1 pages 0.51 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic AW-IF400G, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic AW-IF400G one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Panasonic AW-IF400G. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Panasonic AW-IF400G should contain:
- informations concerning technical data of Panasonic AW-IF400G
- name of the manufacturer and a year of construction of the Panasonic AW-IF400G item
- rules of operation, control and maintenance of the Panasonic AW-IF400G item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic AW-IF400G alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic AW-IF400G, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic AW-IF400G.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic AW-IF400G item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Protocol Con verter A W -IF400G Before attempting to connect, oper ate or adjust this product, please read these instructions completely . FRANÇAIS DEUTSCH ENGLISH IT ALIANO ESP AÑOL 中 文 日本語 Printed in Japan Gedruckt in Japan Imprimé au Japon Stampato in Giappone Impreso en Japón Напеча тано в Японии 在日本印制 M[...]
-
Page 2
CA UTION RI SK O F E L E C TR I C S H O CK D O NO T O PE N CA UTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NO T REMO VE CO VER (OR BA CK). NO USER SER VICEABLE P ARTS INSIDE. REFER T O SER VICING TO QU ALIFIED SER VICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to aler t the user to the pres[...]
-
Page 3
- 2 (E) - ENGLISH indicates saf ety inf ormation. CA UTION: T O REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNO YING INTERFERENCE, USE THE RECOMMENDED A CCESSORIES ONL Y . Note: The rating pla te (se rial number plate) is on the bottom of the unit. W ARNING: • T O REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APP ARA TUS T O RAIN[...]
-
Page 4
- 3 (E) - indicates saf ety inf ormation. 1) Read these instr uctions. 2) Keep these instructions. 3) Heed all war nings. 4) Follow all instructions. 5) Do not use this apparatus near water . 6) Clean only with dr y cloth. 7) Do not block any ventilation openings. Install in accordance with the manuf acturer's instructions. 8 ) Do not install [...]
-
Page 5
- 4 (E) - ENGLISH • P o wer Of f Bef ore Connec ting o r Disc onnect ing Ca bles. Bef ore plugging or unplugging the cables , be sure to s witch power off . • Handle Carefully . Do not drop the product, or subject it to strong shock or vibration. This is impor tant to pre v ent trouble . • A v oid Humidity and Dust. A v oid using the product [...]
-
Page 6
- 5 (E) - Intr oduction By using this unit, A W -PH400 can be controlled from A W -RP605/A W-RP605A/A W-RP655/A W -RP555. Additionally , the controllable distance between A W-RP400 and A W -PH400/A W-PH360 can be e xtended up to 3,280 f eet (1,000 meters). A W -PH350/A W -PH360/A W-PH650 can also be controlled from A W-RP400. Notes The connecti[...]
-
Page 7
- 6 (E) - ENGLISH Major operating contr ols and their functions Po wer LED [PO WER] This lights up green when DC pow er is supplied to the DC 12 V input connector . T ransmission Status LED [COMMUNICA TE] This lights up when data is being transmitted between the controller and pan/tilt head. Extended Distance T ransmission LED [EXTE[...]
-
Page 8
- 7 (E) - Major operating contr ols and their functions Rear panel Controller connector [CONTROLLER] Use the controller CONTROL OUT T O P AN/TIL T terminal and a 10BASE-T (equivalent to UTP category 5) straight cable f or connection. Pan/tilt head connector [P AN-TIL T HEAD] Use the pan/tilt head IP/RP terminal and a 10BASE-T (equivalen[...]
-
Page 9
- 8 (E) - ENGLISH Major operating contr ols and their functions Function Switches [SW1, SW2, SET UP] (F actory defaults: SW1 = OFF , SW2 = OFF , SET UP No .1 = ON, SET UP No .2 to 4 = OFF) This is used to select the operations of the A W-IF400. Bef ore changing a setting, the power m ust be turned off. SETUP No .3 is the tilt range selector s w[...]
-
Page 10
- 9 (E) - Connections • Bef ore proceeding with the connections, turn off the power . • F or fur ther details on connecting the de vices, ref er to the operating instr uctions accompan ying the de vices concerned. • F or fur ther details on operating the de vices , ref er to the operating instructions accompanying the de vices concerned. • [...]
-
Page 11
- 10 (E) - ENGLISH Connections CONTROL OUT T O P AN/TIL T HEAD Main unit Control panel (max. 1000 m) (max. 500 m) Multi-function controller A W-RP605A 10BASE-T (UTP category 5) straight cable A C adapter A W-PS505A Con vertible camera Camera cable supplied with A W-PH400 A C power cable supplied with A W-PH400 Protocol con ver ter A W-IF400G A C ad[...]
-
Page 12
- 11 (E) - Connections (max. 1000 m) (max. 500 m) Multi hybrid contr ol panel A W-RP555 10BASE-T (UTP category 5) straight cable A C adapter A W-PS505A Con vertible camera Camera cable supplied with A W-PH400 A C power cable supplied with A W-PH400 Protocol con ver ter A W-IF400G A C adapter A W-PS505A Zoom lens IP/RP Indoor pan/tilt head A W-PH400[...]
-
Page 13
- 12 (E) - ENGLISH Connections (max. 1000 m) (max. 500 m) Multi-function controller A W-RP655 10BASE-T (UTP category 5) straight cable A C adapter A W-PS505A Con vertible camera Camera cable supplied with A W-PH400 A C power cable supplied with A W-PH400 Protocol con ver ter A W-IF400G A C adapter A W-PS505A Zoom lens IP/RP Indoor pan/tilt head A W[...]
-
Page 14
- 13 (E) - Connections When controlling A W -PH350 fr om A W-RP400 CONTROL IN IP/RP Indoor pan/tilt head A W-PH350 Pan/tilt contr ol panel A W-RP400 CONTROL OUT T O P AN/TIL T HEAD 10BASE-T (UTP category 5) straight cable Protocol con ver ter A W-IF400G Remote operation panel A W-CB400 A C adapter A W-PS505A Con vertible camera Camera cable A W[...]
-
Page 15
- 14 (E) - ENGLISH Connections When controlling A W -PH360 fr om A W-RP400 (The tracing memory function is not availab le.) Set the SW1 switch on the CPU circuit board of A W -PH360 to “F or RP605”. (F or details, ref er to the operating instructions f or the A W-PH360.) CONTROL IN IP/RP Indoor pan/tilt head A W-PH360 Pan/tilt contr ol [...]
-
Page 16
- 15 (E) - Connections When controlling A W -PH650 fr om A W-RP400 ( For the connections of the A W -PH650 pan/tilt head, camera housing, and camera, ref er to the operating instructions f or the A W-PH650.) Pan/tilt contr ol panel A W-RP400 CONTROL OUT T O P AN/TIL T HEAD 10BASE-T (UTP category 5) straight cable Protocol con ver ter A W-IF400G[...]
-
Page 17
- 16 (E) - ENGLISH Connections Pan/tilt contr ol panel A W-RP400 Remote operation panel A W-CB400 CONTROL OUT T O P AN/TIL T HEAD 10BASE-T (UTP category 5) straight cable Protocol con ver ter A W-IF400G IP/RP Indoor pan/tilt head A W-PH400 When using the extended distance transmission function of A W -RP400 and A W-PH400 A C adapter A W-PS505A [...]
-
Page 18
- 17 (E) - Indoor pan/tilt head A W-PH360 Pan/tilt contr ol panel A W-RP400 CONTROL OUT T O P AN/TIL T HEAD 10BASE-T (UTP category 5) straight cable Protocol con ver ter A W-IF400G Remote operation panel A W-CB400 A C adapter A W-PS505A Con vertible camera Camera cable supplied with A W-PH360 A C adapter A W-PS300A Zoom lens A C adapter A W-PS505A [...]
-
Page 19
- 18 (E) - ENGLISH 1/4 (6) 1-15/16 (50) 9/16 (15) 5-11/16 (145) 3-3/8 (85) 1-3/16 (30) Appearance For mounting and other applications, use the scre w (M3 screw) holes in the side panels . Do not use screws longer than 10 mm. Unit: inch (mm) M3 screw hole (in 4 locations) ( Located in the same positions on both sides)[...]
-
Page 20
- 19 (E) - Specifications Controller supported: A W -RP400, A W -RP555, A W-RP605, A W-RP605A, A W -RP655 P an/tilt head supported: A W -PH350, A W -PH360, A W-PH400, A W-PH650 Input connectors DC 12 V IN sock et: Supply DC 12 V from the general-purpose AC adapter . (Recommended A C adapter : A W -PS505A) Input/Output connector CONTROLLER: RJ45, mo[...]
-
Page 21
- 20 (E) - ENGLISH[...]
-
Page 22
Protocol Con verter A W -IF400G Before attempting to connect, oper ate or adjust this product, please read these instructions completely . FRANÇAIS DEUTSCH ENGLISH IT ALIANO ESP AÑOL 中 文 日本語 Printed in Japan Gedruckt in Japan Imprimé au Japon Stampato in Giappone Impreso en Japón Напеча тано в Японии 在日本印制 M[...]