Go to page of
Similar user manuals
-
Air Conditioner
Panasonic CU-E21DKR
12 pages 11.86 mb -
Air Conditioner
Panasonic CS-MKE24NKU
122 pages 2.51 mb -
Air Conditioner
Panasonic CU-CE12GKE
24 pages 1.99 mb -
Air Conditioner
Panasonic CU-XE9DKE
44 pages 25.42 mb -
Air Conditioner
Panasonic CU-KS24NKU
122 pages 2.46 mb -
Air conditioner
Panasonic WH-UX09HE8
108 pages 2.14 mb -
Air Conditioner
Panasonic CU-E24GKR
8 pages 2.15 mb -
Air conditioner
Panasonic CU-YL34GBE5
64 pages 2.3 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic CS-XE12EKE, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic CS-XE12EKE one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Panasonic CS-XE12EKE. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Panasonic CS-XE12EKE should contain:
- informations concerning technical data of Panasonic CS-XE12EKE
- name of the manufacturer and a year of construction of the Panasonic CS-XE12EKE item
- rules of operation, control and maintenance of the Panasonic CS-XE12EKE item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic CS-XE12EKE alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic CS-XE12EKE, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic CS-XE12EKE.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic CS-XE12EKE item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
F565101 CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE Manufactured by: Panasonic HA Air-Conditioning (M) Sdn. Bhd. Lot 2, Persiaran T engku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor , Malaysia. Operating Instructions Air Conditioner © 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd (1 1969-T). All rights reserved. Unautho[...]
-
Page 2
2 This symbol denotes an action that is PROHIBITED. These symbols denote actions that are COMPULSORY . ■ Definition W arning Caution T o prevent personal injury , injury to others, or property damage, please observe the following. Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is class[...]
-
Page 3
3 ENGLISH Replacement or installation of power plugs shall be performed by authorized/quali fi ed personnel only .The wires in this mains lead are coloured in accordance with the following code: Wiring colour may vary depending on a country wiring code’s standard. T erminals wires live neutral colours (GB Standard) brown blue red black green-yel[...]
-
Page 4
4 ■ About PR ODUCT O VERVIEW Air inlet (rear) Air outlet Air inlet (side) Outdoor Unit Outdoor Unit Auto OFF/ON Button Indoor Unit Indoor Unit Indicator Receiver Auto OFF/ON button Filter cleaning device Airflow direction louver Air filter fastener Movable front panel* Super alleru buster filter Filter cleaning indication light Air intake Dischar[...]
-
Page 5
5 ENGLISH R emote Contr ol R emote Contr ol PR ODUCT O VERVIEW T r oubleshooting - er ror code checking ■ About Remote Control Preparation • Make sure it is not obstructed. • Maximum distances: 8m. • Certain fluorescent lights may interfere with signal transmission. Please consult your nearest authorized dealer . Remote Control Signal 6. Pr[...]
-
Page 6
6 INTR O T O FIL TER CLEANING ■ About Filter cleaning Filter cleaning function helps to: • Clean the filters automatically on a regular basis. • Avoid airflow blockage caused by dusty filter . • Prevent growth of mold inside the unit. • Improve heating/cooling effect that saves energy consumption. Aut o F ilter Cl eaning Filter Cleaning D[...]
-
Page 7
7 ENGLISH A UT O FIL TER CLEANING Auto F ilter Cl eaning A UT O AU TO • Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned off using remote control). • After the filter cleaning is completed, the air conditioner operation will remain off. AIR CONDITIONER TIMER AIR CONDITIONER TIMER • Fi[...]
-
Page 8
8 TIMER FIL TER CLEANING ● T o cancel fi lter cleaning timer , press , then press . Press to set cleaning timer . 1 1 Press to turn on cleaning timer . ON is shown on the display . 2 2 Press to con fi rm the setting. is shown on the display . Press to select your desired time. 3 3 4 ■ About • Filter cleaning timer can be set to run at a spe[...]
-
Page 9
9 ENGLISH MANU AL FIL TER CLEANING ● Press to cancel manual fi lter cleaning. ■ About • Press once to run a comprehensive fi lter cleaning. • A comprehensive fi lter cleaning may take less than an hour to complete. • When is pressed, this operation has the highest priority over other operation modes. The air conditioner operation will [...]
-
Page 10
10 CHANGE FIL TER CLEANING DEF A UL T SETTING ■ Hint • Manual fi lter cleaning is operable by pressing . For detail, see manual fi lter cleaning page. ■ Setting • T o disable the fi lter cleaning permanently , follow steps 1 to 3 as shown below . Disable Filter Cleaning Press and hold for more than 20 seconds. ON will blink on the displa[...]
-
Page 11
11 ENGLISH A UT O , HEA T , COOL, DR Y ● , and operations are available in all modes. ● Press to stop the operation. Select your desired operation. 1 1 Select your desired temperature. (16°C~30°C) ■ Operation Details COOL - Cooling Operation • Enjoy cool air at your desired temperature. DR Y - Soft Dr y Operation • Keeps your environmen[...]
-
Page 12
12 VENTILA TION Select your desired ventilation setting. ■ Operation Details • T o aerate the room. • As a default setting, ventilation will be turned on automatically once the air conditioner operation starts. • Operates simultaneously with Auto/ Cooling/Heating/Drying operation. • Press repeatedly to select your desired ventilation sett[...]
-
Page 13
13 ENGLISH ■ Operations Details • There are 5 fan speeds, as well as automatic*. * For automatic fan speed, the speed of the indoor fan is automatically adjusted according to the operation. F AN SPEED , AIR SWING T r oubleshooting ● The room has a peculiar odour . ► This may be a damp smell emitted by the wall, carpet, furniture or clothing[...]
-
Page 14
14 PO WERFUL, QUIET ● and operations are not able to operate at the same time. ● and operations could be cancelled by pressing the respective button again. T o enable quiet operation. T o enable powerful operation. ■ Operations Details • T o reach the desired set temperature quickly . • T o provide a quiet surrounding. ■ Hint • T o re[...]
-
Page 15
15 ENGLISH ■ Operation Details TIMER • The timer allows you to turn the air conditioner on or off automatically . • The unit may start in preliminary operation before the actual set time when ON timer has been set. • The set timer repeats daily once set. • If there is a power failure, you can restore the previous setting (once power is re[...]
-
Page 16
16 ■ Hint • Please consult your nearest authorized dealer for seasonal inspection. CARE & MAINTEN ANCE • Wipe the unit gently with a soft, dry cloth. INDOOR UNIT • Do not remove the movable part from the front panel. • Soak cloth/sponge in lukewarm water with detergent. Squeeze it dry and wipe the panels. Repeat same step again, but t[...]
-
Page 17
17 ENGLISH CARE & MAINTEN ANCE S S witc h of f the po wer supply witc h of f the po wer supply bef or e c leaning bef or e c leaning REMO VE THE FRONT AIR FIL TER REMO VE THE FRONT AIR FIL TER Push upwards to unlock the air fi lter fastener . REMO VE THE T OP AIR FIL TER REMO VE THE T OP AIR FIL TER REMO VE THE SUPER ALLERU-B USTER FIL TER REM[...]
-
Page 18
11 4 SEASONAL INSPECTION AFTER EXTENDED NON-USE: • Checking of remote control batteries. • No obstruction at inlet and outlet vents. • After 15 minutes of operation, it is normal to have the following temperature difference between inlet and outlet vents: Cooling: ≥ 8°C Heating: ≥ 14°C INSPECCIÓN PERIÓDICA TRAS NO UTILIZAR LA UNID AD [...]
-
Page 19
11 5 ИЗКЛЮЧЕТЕ ЗАХРАНВАНЕТО и се ОБАДЕТЕ на оторизирания дистрибутор при следните условия : • Необичаен звук по време на работа . • Прекъсва чът на ел . верига се изклю чва често . • Вода / чужди ?[...]
-
Page 20
Matsushita Electric Industrial Co ., Ltd. Web Site: http://www .panasonic.co.jp/global/ F565101 Printed in Malaysia OPSC0601-02[...]