Panasonic CU-CE12GKE manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic CU-CE12GKE, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic CU-CE12GKE one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Panasonic CU-CE12GKE. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Panasonic CU-CE12GKE should contain:
- informations concerning technical data of Panasonic CU-CE12GKE
- name of the manufacturer and a year of construction of the Panasonic CU-CE12GKE item
- rules of operation, control and maintenance of the Panasonic CU-CE12GKE item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic CU-CE12GKE alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic CU-CE12GKE, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic CU-CE12GKE.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic CU-CE12GKE item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    © 2007 Panasonic HA Air-Condit ioning (M) Sdn. Bhd. (1 1969-T). All ri ghts reserved. Unauthor ized copying and distribution is a violation of law . Order No. MAC07060 0 2 A 2 Air Conditioner CS-CE7GKEW CU-CE7GKE CS-CE9GKEW CU-CE9GKE CS-CE12GKEW CU-CE12GKE T ABLE OF CONTENTS PA G E PA G E 1 Specifications ---------- -------------------------------[...]

  • Page 2

    2 1 S pecifications 1.1. CS-CE7GKEW CU-CE7G KE ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance T est Condition EUROVENT C O O L I N G Capacity kW 2.05 (0.70 ~ 2.40) kCal/h 1760 (600 ~ 2060) EER W/W 4.27 (4.12 ~ 4.07) kCal/hW 3.67 (3.53 ~ 3.49) Noise Level dB (A) High 37, Low 24, Q-Lo 21 High 45 Power level dB High 48, Low 35, Q-Lo 32 58 H E A T I N [...]

  • Page 3

    3 1. Cooling capacities are based on indoor tempera ture of 27 ° C D.B. (80.6 ° F D.B.), 19.0 ° C W .B. (66.2 ° F W .B.) and outdoor air temperature of 35 ° C D.B. (95 ° F D.B.), 24 ° C W .B. (75 .2 ° F W .B.) 2. Heating capacities are based on indoo r temperature of 20 ° C D.B. (68 ° F D.B.) and outdoor air te mperature of 7 ° C D.B. (4[...]

  • Page 4

    4 1.2. CS-CE9GKEW CU-CE9G KE ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance T est Condition EUROVENT C O O L I N G Capaci ty kW 2.60 (0.80 ~ 3.00) kCal/h 2240 (690 ~ 2580) EER W/W 4.41 (4.57 ~ 4.00) kCal/hW 3.80 (3.94 ~ 3.44) Noise Level dB (A) High 39, Low 25, Q-Lo 21 High 46 Power level dB High 50, Low 36, Q-Lo 32 59 H E A T I N G Capaci ty kW 3.[...]

  • Page 5

    5 1. Cooling capacities are based on indoor tempera ture of 27 ° C D.B. (80.6 ° F D.B.), 19.0 ° C W .B. (66.2 ° F W .B.) and outdoor air temperature of 35 ° C D.B. (95 ° F D.B.), 24 ° C W .B. (75 .2 ° F W .B.) 2. Heating capacities are based on indoo r temperature of 20 ° C D.B. (68 ° F D.B.) and outdoor air te mperature of 7 ° C D.B. (4[...]

  • Page 6

    6 1.3. CS-CE12GKEW CU-CE12GKE ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance T est Condition EUROVENT C O O L I N G Capacity kW 3.50 (0.80 ~ 4.00) kCal/h 3010 (690 ~ 3440) EER W/W 3.83 (4.32 ~ 3.39) kCal/hW 3.29 (3.73 ~ 2.92) Noise Level dB (A) High 42, Low 28, Q-Lo 21 High 48 Power level dB High 53, Low 39, Q-Lo 32 61 H E A T I N G Capacity kW 4.8[...]

  • Page 7

    7 1. Cooling capacities are based on indoor tempera ture of 27 ° C D.B. (80.6 ° F D.B.), 19.0 ° C W .B. (66.2 ° F W .B.) and outdoor air temperature of 35 ° C D.B. (95 ° F D.B.), 24 ° C W .B. (75 .2 ° F W .B.) 2. Heating capacities are based on indoo r temperature of 20 ° C D.B. (68 ° F D.B.) and outdoor air te mperature of 7 ° C D.B. (4[...]

  • Page 8

    8 2 T echnical Dat a 2.1. Operation Characteristics 2.1.1. CS-CE7GKEW CU-CE7GKE[...]

  • Page 9

    9[...]

  • Page 10

    10[...]

  • Page 11

    11[...]

  • Page 12

    12 2.1.2. CS-CE9GKEW CU-CE9GKE[...]

  • Page 13

    13[...]

  • Page 14

    14[...]

  • Page 15

    15[...]

  • Page 16

    16 2.1.3. CS-CE12GKEW CU-CE12GKE[...]

  • Page 17

    17[...]

  • Page 18

    18[...]

  • Page 19

    19[...]

  • Page 20

    20 2.2. Sensible Cap acity Chart O CS-CE7GKEW CU-CE7GKE O CS-CE9GKEW CU-CE9GKE O CS-CE12GKEW CU-CE12GKE 230V Outdoor T emp. ( ° C) Indoor wet bulb temp. 30 35 40 46 T C S H C I PT C S H C I PT C S H C I PT C S H C I P 17.0 ° C 2.03 1.54 0.44 1.90 1.48 0.47 1.77 1.42 0.51 1.61 1.35 0.55 19.0 ° C 2.05 0.48 19.5 ° C 2.23 1.61 0.45 2.09 1.55 0.48 1[...]

  • Page 21

    21 3 Exploded V iew and Replacement Part s List 3.1. Indoor Unit Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.[...]

  • Page 22

    22 (NOTE) • All parts are supplied from PHAAM, Malaysia (V endor Code: 061). • “O” marked parts are recommended to be kept in stock. REF . NO. P ART NAME & DESCRIPTION QTY . CS-CE7GKEW CS-CE9GKEW CS-CE12GKEW REMARKS 1 CHASSY COMPLETE 1 CWD50 C1513 ←← 2 F AN MOTOR 1 ARW61F8P30AC ←← O 3 CROSS FLOW F AN COMPLETE 1 CWH02 C1045 ←?[...]

  • Page 23

    23 3.2. Out door Unit Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.[...]

  • Page 24

    24 (NOTE) • All parts are supplied from PHAAM, Malaysia (V endor Code: 061). • “O” marked parts are recommended to be kept in stock. [PHAAM] Printed in Malaysia SFYW0706 - 00 REF . NO. P ART NAME & DESCRIPTION Q TY . CU-CE7GKE CU-CE9GKE CU-CE12GKE REMA RKS 1 CHASSY ASS’Y 1 CWD50K2073 ←← 2 SOUND PROOF MA TERIAL 1 CWG302314 ←← 3[...]