Go to page of
Similar user manuals
-
Home Safety Product
Panasonic EY3796
10 pages 0.17 mb -
Home Safety Product
Panasonic FX-301
66 pages 13.49 mb -
Home Safety Product
Panasonic EY3795
10 pages 0.17 mb -
Home Safety Product
Panasonic EY3794
10 pages 0.17 mb -
Home Safety Product
Panasonic Sensor Series
11 pages 0.19 mb -
Home Safety Product
Panasonic EY3794-U1
2 pages 0.09 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic FX-301, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic FX-301 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Panasonic FX-301. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Panasonic FX-301 should contain:
- informations concerning technical data of Panasonic FX-301
- name of the manufacturer and a year of construction of the Panasonic FX-301 item
- rules of operation, control and maintenance of the Panasonic FX-301 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic FX-301 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic FX-301, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic FX-301.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic FX-301 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
FX-301 Digital Fiber Sensor Superior performance and advanced user -friendly multi-functionality enables expert usage on the ver y first day 68 SERIES Long-range sensing made possible with built-in optical lens Stable long-term sensing Enhanced worksite-friendl y installability F or the first time in the industr y , an optical ‘double coupling le[...]
-
Page 2
69 FX-301 Even beginners can quic kly learn ho w to use the MODE NA VI MODE NA VI uses six indicators to display the amplifier’ s basic operations. The current operating mode can be confirmed at a glance, so e ven a first time user can easily oper ate the amplifier without becoming confused. Easy maintenance, as main and sub units are identical B[...]
-
Page 3
70 FX-301 4 types of light sources a vailab le In addition to our red LED (f our-chemical emitting element) type, the b lue, green, and infrared LED types are also provided to correspond to your specific application. Easy code input setting Every function can be directly set merely by the input of a f our digit code (numbers) from the code tab le. [...]
-
Page 4
71 FX-301 Optional units for greater freedom and contr ol when installing Sensor-PLC connection system This wire-saving system enab les the collective connection of up to 16 I/O de vices with an MIL connector . Scattered installation is also possible with the help of a sensor separate unit. SC SERIES Bank selection unit Without directly manipulatin[...]
-
Page 5
72 FX-301 ORDER GUIDE T ype Appearance Model No . Emitting element Output NPN output PNP output Digital FX-301 FX-301B FX-301G FX-301H FX-301P FX-301BP FX-301GP FX-301HP Red LED Blue LED Green LED Infrared LED Red LED Blue LED Green LED Infrared LED Amplifiers NPN open-collector transistor PNP open-collector transistor Quick-connection cab les T yp[...]
-
Page 6
73 FX-301 FT -FM10L FT -SFM2L FT -B8 FT -NB8 FT -FM2 FT -FM2S FT -FM2S4 FT -T80 FT -SFM2 FT -N8 FT -NFM2 FT -NFM2S FT -NFM2S4 FT -SNFM2 FT -R80 FT -V10 FT -SFM2SV2 FT -V22 FT -V41 140 5.512 R25 mm R0.984 in R25 mm R0.984 in Fiber R25 mm R0.984 in Sleev e R25 mm R0.984 in R25 mm R0.984 in Fiber R25 mm R0.984 in Sleev e R25 mm R0.984 in R25 mm R0.984[...]
-
Page 7
74 FX-301 FT -WV42 FT -Z8H FT -Z8E FT -Z8 FT -P80 FT -P60 FT -P40 FT -P2 FT -PS1 FT -W8 FT -WS3 FT -WS8 FT -WZ8H FT -WZ8E FT -WZ8 FT -WKV8 FT -WS8L " 0.3 mm " 0.012 in opaque object " 0.25 mm " 0.010 in opaque object FT -W A30 FT -W A8 400 15.748 200 7.874 140 5.512 240 9.449 120 4.724 80 3.150 80 3.150 40 1.575 25 0.984[...]
-
Page 8
75 FX-301 R25 mm R0.984 in R25 mm R0.984 in 600 23.622 300 11.811 220 8.661 120 4.724 60 2.362 40 1.575 120 4.724 60 2.362 40 1.575 80 3.150 35 1.378 10 0.394 3 0.118 2 0.079 1 0.039 14 0.551 7 0.276 4 0.157 130 5.118 64 2.520 45 1.772 300 11.811 150 5.906 110 4.331 60 2.362 30 1.181 20 0.787 60 2.362 30 1.181 20[...]
-
Page 9
76 FX-301 100 3.937 50 1.969 35 1.378 44 1.732 22 0.866 14 0.551 100 3.937 50 1.969 35 1.378 72 2.835 36 1.417 26 1.024 320 12.598 160 6.299 120 4.724 160 6.299 80 3.150 50 1.969 120 4.724 60 2.362 35 1.378 100 3.937 50 1.969 30 1.181 36 1.417 18 0.709 12 0.472 50 1.969 25 0.984 18 0.709 22 0.866 11 0.433 7 0[...]
-
Page 10
77 FX-301 FD-B8 FD-5 FD-FM2 FD-FM2S FD-FM2S4 FD-T80 FD-T40 FD-S80 FD-N8 FD-N4 FD-NFM2 FD-NFM2S FD-NFM2S4 FD-SNFM2 FD-R80 FD-SFM2SV2 FD-V41 80 3.150 40 1.575 26 1.024 46 1.811 23 0.906 15 0.591 46 1.811 23 0.906 15 0.591 46 1.811 23 0.906 15 0.591 46 1.811 23 0.906 15 0.591 16 0.630 8 0.315 5 0.197 46 1.811 23 0.906 15 0.591 [...]
-
Page 11
78 FX-301 FD-WKZ1 FD-W8 FD-W44 FD-WT8 FD-WS8 FD-WT4 FD-WG4 FD-WSG4 FD-WL41 FD-WL42 FD-WV42 FD-P80 FD-P60 FD-P50 FD-P40 FD-P2 23 0.906 11 0.433 8 0.315 5 0.197 2.5 0.098 1.5 0.059 23 0.906 11 0.433 8 0.315 5 0.197 2.5 0.098 1.5 0.059 11 0.433 5 0.197 3 0.118 40 1.575[...]
-
Page 12
79 FX-301 FD-EG1 FD-EG2 FD-EG3 FD-E12 FD-E22 FD-EN500S1 FD-ENM1S1 LIST OF FIBERS Special use Wide beam Arra y High precision Ultra-small diameter Liquid lev el sensing T ough flexible Fixed-f ocus reflective Special use fibers (Reflective type) :LONG :STD :F AST :S-D Sensing range (mm in ) (Note 1, 2) Red LED Blue LED Green LED Infrared LED 200 7.8[...]
-
Page 13
80 FX-301 FD-H35-M2 FD-H35-M2S6 FD-H20-M1 FD-H35-20S FD-H20-21 FD-H30-L32 FD-H18-L31 FD-H13-FM2 FD-6V 36 1.417 18 0.709 12 0.472 22 0.866 11 0.433 7 0.276 36 1.417 18 0.709 12 0.472 20 0.787 11 0.433 7 0.276 26 1.024 13 0.512 9 0.354 20 0.787 10 0.394 7 0.276 12 0.472 6 0.236 4 0.157 20 0.787 10 0.394 7 0[...]
-
Page 14
81 FX-301 1,000 1,300 1,300 800 1,000 1,100 900 1,100 750 500 500 900 FT -B8 FT -FM2 FT -T80 FT -R80 FT -W8 FT -P80 FT -P60 FT -P81X FT -H35-M2 FT -H20W-M1 FT -H20W-M2 FT -H20-M1 3,500 ( Note 3 ) 3,500 ( Note 3 ) 3,500 ( Note 3 ) 3,500 ( Note 3 ) 3,500 ( Note 3 ) 3,500 ( Note 3 ) 3,500 ( Note 3 ) 3,500 ( Note 3 ) 3,500 ( Note 3 ) 1,600 ( Note 3 ) 2[...]
-
Page 15
82 FX-301 FX-CT2 FX-CT1 FTP-500 (0.5 m 1.640 ft ) FTP-1000 (1 m 3.281 ft ) FTP-1500 (1.5 m 4.921 ft ) FTP-N500 (0.5 m 1.640 ft ) FTP-N1000 (1 m 3.281 ft ) FTP-N1500 (1.5 m 4.921 ft ) FDP-500 (0.5 m 1.640 ft ) FDP-1000 (1 m 3.281 ft ) FDP-1500 (1.5 m 4.921 ft ) FDP-N500 (0.5 m 1.640 ft ) FDP-N1000 (1 m 3.281 ft ) FDP-N1500 (1.5 m 4.921 ft ) FB-1 MS-[...]
-
Page 16
83 FX-301 12 to 24 V DC 10 % Ripple P-P 10 % or less < Red LED / Infrared LED type > Normal operation: 960 mW or less Current consumption 40 mA or less at 24 V supply voltage ECO mode: 600 mW or less Current consumption 25 mA or less at 24 V supply voltage NPN open-collector transistor • Maximum sink current:100 mA 50 mA, if five , or m[...]
-
Page 17
84 FX-301 R25 mm R0.984 in or more [Sleev e of a head with sleev e:R10 mm R0.394 in or more (Note 1)] 40 to 70 °C 40 to 158 °F FT -SFM2SV2 : 20 to 70 °C 4 to 158 °F FT -V22 , FD-SFM2SV2 : 20 to 60 °C 4 to 140 °F FT -V41 , FD-V41 , FT -V10 : 40 to 60 °C 40 to 140 °F 35 to 85%RH [...]
-
Page 18
85 FX-301 R10 mm R0.394 in or more 40 to 100 °C 40 to 212 °F (Note 1) P olyeth ylene P olyetherimide (Lens: P olycarbonate) 1 fiber attachment set, FX-CT2 (fiber cutter) 1pc. T ying bands 4 pcs., anti-slip tubes 2 pcs. Protective tube: R40 mm R1.575 in or more Fiber: R15 mm R0.591 in or more 40 to 125 °C 40 to 257[...]
-
Page 19
86 FX-301 I/O CIRCUIT AND WIRING DIA GRAMS I/O circuit dia gram Wiring diagram Notes: 1) The quick-connection sub cab le does not have V (bro wn) and 0 V (blue) . Notes: 2) 50 mA max., if five amplifiers , or more, are connected together . Symbols … D : Re verse supply polarity protection diode Z D : Surge absor ption zener diode T r : NPN ou[...]
-
Page 20
87 FX-301 SENSING CHARA CTERISTICS (TYPICAL) P arallel deviation FT -FM10L FT -SFM2L FT -B8 FT -NB8 FT -FM2 FT -FM2S FT -FM2S4 FT -T80 FT -SFM2 FT -N8 FT -NFM2 FT -NFM2S FT -NFM2S4 FT -SNFM2 FT -R80 FT -V10 FT -SFM2SV2 FT -V22 FT -V41 L Thru-beam type Thru-beam type Thru-beam type Thru-beam type Thru-beam type Thru-beam type Thru-beam type Thru-bea[...]
-
Page 21
88 FX-301 FT -WS8L FT -W8 FT -WS8 FT -WS3 FT -W4 FT -WS4 FT -WZ8H FZ-WZ8E Thru-beam type Thru-beam type Thru-beam type FT -WZ8 Thru-beam type Thru-beam type Thru-beam type Thru-beam type P arallel deviation FT -W A30 FT -A30 FT -W A8 FT -A8 L Thru-beam type Thru-beam type Horizontal direction Vertical direction Horizontal direction V ertical direct[...]
-
Page 22
89 FX-301 P arallel deviation FT -WV42 Thru-beam type Horizontal direction V ertical direction Horizontal direction V ertical direction FT -Z8 FT -P80 FT -P60 FT -P40 Thru-beam type Thru-beam type Thru-beam type Thru-beam type FT -Z8H FT -Z8E Thru-beam type Thru-beam type FT -P2 FT -PS1 Thru-beam type Thru-beam type FT -AFM2 Thru-beam type Horizont[...]
-
Page 23
90 FX-301 P arallel deviation FT -KV1 Thru-beam type Horizontal direction V ertical direction FT -KV8 Thru-beam type Horizontal direction V ertical direction FT -P81X FT -H35-M2 FT -H35-M2S6 FT -H20W -M1 FT -H20W -M2 FT -H20-M1 Thru-beam type Thru-beam type Thru-beam type Thru-beam type FT -E12 FT -E22 Thru-beam type Thru-beam type FT -H13-FM2 FT -[...]
-
Page 24
91 FX-301 FT -Z802Y FT -6V FT -60V Thru-beam type Thru-beam type Thru-beam type P arallel deviation P arallel deviation with FX-LE2 (super-e xpansion lens) applied on both sides P arallel deviation with FX-LE1 (expansion lens) applied on both sides FT -B8 FT -W8 FT -P80 FT -H35-M2 Thru-beam type Thru-beam type Thru-beam type Thru-beam type FT -H20W[...]
-
Page 25
92 FX-301 P arallel deviation with FX-SV1 (side-view lens) applied on both sides P arallel deviation with FX-LE2 (super-e xpansion lens) applied on both sides FT -B8 Thru-beam type Horizontal direction V er tical direction FT -W8 Thru-beam type Horizontal direction FT -P80 Thru-beam type FT -H35-M2 Thru-beam type FT -H20W -M2 Thru-beam type FT -H20[...]
-
Page 26
93 FX-301 FD-B8 FD-5 FD-FM2 FD-T80 FD-S80 FD-FM2S FD-FM2S4 FD-T40 FD-NFM2 FD-NFM2S FD-NFM2S4 FD-SNFM2 Reflective type Reflective type Reflective type Reflective type Sensing fields FD-SFM2SV2 Reflective type Horizontal direction Vertical direction Horizontal direction Vertical direction Horizontal direction V ertical direction FD-V41 Reflective typ[...]
-
Page 27
94 FX-301 FD-A15 Reflective type Horizontal direction Vertical direction FD-AFM2 FD-AFM2E Reflective type Horizontal direction V ertical direction FD-EG1 FD-EG2 Reflective type Reflective type FD-G4 FD-G6 Reflective type Reflective type Sensing fields FD-P60 FD-P50 Reflective type Reflective type FD-P40 Reflective type FD-P2 Reflective type SENSING[...]
-
Page 28
95 FX-301 FD-EG3 Reflective type FD-EN500S1 Reflective type FD-E12 Reflective type FD-E22 Reflective type Sensing fields FD-ENM1S1 FD-P81X Reflective type Reflective type FD-G6X Reflective type FD-H35-M2 FD-H35-M2S6 Reflective type FD-H20-M1 FD-H35-20S Reflective type Reflective type FD-H20-21 Reflective type FD-H30-L32 FD-H18-L31 Reflective type F[...]
-
Page 29
96 FX-301 • Make sure that the po wer supply is off while cascading or removing the amplifier . • Make sure to chec k the allowab le ambient temperature , as it depends on the number of amplifiers connected in cascade. • In case two , or more, amplifiers are connected in cascade , make sure to mount them on a DIN r ail. • When connecting in[...]
-
Page 30
97 FX-301 The threshold value is displa yed. ‘ ’ blinks in the digital displa y . The incident light intensity appears in the digital display and the setting is complete . 6 5 7 8 If jog switch is turned to the ‘ ’ side, ‘ ’ scrolls (twice) the display from right to left, and the threshold lev el is shifted to a value appro x. 15 % [...]
-
Page 31
98 FX-301 PRECA UTIONS FOR PROPER USE Amplifier Threshold value fine adjustment Ke y-lock function Press MODE ke y to light up MODE indicator / ADJ (yellow). When jog switch is pressed, the threshold value is confirmed. 1 2 2 Step Description Display In case the threshold value is to be increased (sensitivity to be reduced), turn the jog switch to [...]
-
Page 32
99 FX-301 PRECA UTIONS FOR PROPER USE Amplifier PRO mode T able for PR O mode settings • Ref er to the ‘Fiber Sensor Guide Book’ for more details per taining to the PRO mode settings and procedures . • The abov e can also be download from ‘SUNX fiber sensor homepage’ (http://www .fiber-sensor.com) • PRO settings can be done when MODE [...]
-
Page 33
100 FX-301 M3 M4 M5 M6 M14 0.39 N·m 0.58 N·m 350 °C 662 °F heat-resistant fiber and FT -H20W-M : 0.98 N m, FD-H35-20S : 0.58 N m 0.98 N·m 350 °C 662 °F heat-resistant fiber: 1.96 N m 1.47 N m PRECA UTIONS FOR PROPER USE Fiber FT -PS1 FD-E12 FT -V22 FT -41, FD-V41 FT -SFM2SV2 FD-EG1 FT -WV42 FD-WV42 FD-SFM2SV2 FT -KV8, FT [...]
-
Page 34
101 FX-301 PRECA UTIONS FOR PROPER USE Fiber • Mount the fiber head by using the enclosed set of scre ws. The tightening torque should be 0.15 N m or less • If the fiber head is mounted in places subject to vibrations or shocks , use a screw-loc king adhesive , etc. • Mount each fiber head as given belo w . Mounting FT -Z8 and FT -WZ8[...]
-
Page 35
• Protect the amplifier from heat radiation or hot air . • With the 350 C 662 °F heat-resistant type fiber , the surf ace of the fiber head or the spiral may be discolored by heat. How ev er , this does not aff ect its performance. 102 FX-301 Connection with reflective coaxial type fiber • With reflective coaxial type fiber , inser t the[...]
-
Page 36
< FX-A T10, FX-A T13 > 1 Thread the fiber cable through the gland and holder separately , and screw the gland into the holder clockwise . 2 Inser t the fiber cables one b y one into the holes f or " 1.0 mm " 0.039 in or " 1.3 mm " 0.051 in fiber cable of the fiber cutter ( FX-CT2 ) from the direction shown in the figure ri[...]
-
Page 37
104 FX-301 Fiber PRECA UTIONS FOR PROPER USE . Fiber cutter (FX-CT2) • T o cut the fiber cables , inser t them from the direction shown below . (Fiber cable insertion direction) 1 Slide par t of the fiber cutter fully upward till it stops . 2 Inser t the fiber cables , mounted in the attachment, till they stop . T ake care that there are separ at[...]
-
Page 38
105 FX-301 Fiber PRECA UTIONS FOR PROPER USE . FT -L8Y/V8Y chemical-resistant type fiber • Do not use it in the f ollowing chemicals: Dissolved alkali metals (Natrium, P otassium or Lithium), Fluorine gas (F 2 ), CIF 3 , OF 2 (including gaseous state). • The beam axis mark is indicated on the side-view fiber . P erf or m the beam alignment with[...]
-
Page 39
106 FX-301 PRECA UTIONS FOR PROPER USE . Fiber FD-F4 and FD-F9 liquid level sensing fiber • Mount the fiber head on a pipe with the attached tying bands and anti-slip tubes as shown in the figure belo w . Make sure that the release le v er is retracted (position as in the fig.) bef ore mounting. F asten two tying bands , as shown, and cut[...]
-
Page 40
107 FX-301 PRECA UTIONS FOR PROPER USE . Fiber Cautions for FX-MR5 side-vie w zoom lens usage • The spot diameter and the sensing range are adjustab le by the scre w-in depth as follo ws. Fitting protective tube • The threaded head free-cut fiber can be fitted with a protective tube . • The maximum tightening torque should be as giv en below [...]
-
Page 41
108 FX-301 DIMENSIONS (Unit: mm in ) Main cable (Optional) CN-73-C1 CN-73-C2 CN-73-C5 Sub cable (Optional) CN-71-C1 CN-71-C2 CN-71-C5 Amplifier mounting brac ket (Optional) MS-DIN-2 End plate (Optional) MS-DIN-E Model No . CN-71-C1 CN-71-C2 CN-71-C5 Length (mm in ) 1,000 39.370 2,000 78.740 5,000 196.850 • Length (L) Model No . CN-73-C1 CN-73-C2 [...]
-
Page 42
109 FX-301 DIMENSIONS (Unit: mm in ) Toothed lock washer " 23 " 0.906 FT -FM10L F ree-cut FT -SFM2L FT -B8 FT -NB8 FT -FM2 Toothed lock washer " 8.5 " 0.335 FT -FM2S FT -FM2S4 FT -T80 FT -SFM2 FT -N8 FT -NFM2 Thru-beam type fibers With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T5 F ree-cut F ree-c[...]
-
Page 43
110 FX-301 DIMENSIONS (Unit: mm in ) FT -R80 F ree-cut FT -V10 FT -SFM2SV2 FT -V22 15 0.591 FT -V41 FT -W A30 FT -W A8 FT -WZ8H FT -WZ8E Thru-beam type fibers With FX-A T3 With FX-A T2 F ree-cut With FX-A T3 With FX-A T5 F ree-cut F ree-cut With FX-A T3 With FX-A T3 F ree-cut F ree-cut With FX-A T4 F ree-cut With FX-A T3 F ree-cut With FX-A T5 FT -[...]
-
Page 44
111 FX-301 DIMENSIONS (Unit: mm in ) FT -WS8L F ree-cut FT -W8 FT -WS3 FT -WS8 FT -W4 FT -WS4 FT -WV42 FT -Z8H FT -Z8E FT -Z8 Thru-beam type fibers With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T4 With FX-A T5 F ree-cut F ree-cut With FX-A T3 With FX-A T3 F ree-cut F ree-cut With FX-A T4 F ree-cut With FX-A T5 F ree[...]
-
Page 45
112 FX-301 DIMENSIONS (Unit: mm in ) FT -P40 F ree-cut FT -P2 FT -PS1 FT -A30 FT -A8 FT -AFM2 FT -AFM2E FT -K8 FT -KV8 FT -KV1 Thru-beam type fibers With FX-A T4 With FX-A T2 F ree-cut With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T2 With FX-A T3 With FX-A T3 F ree-cut F ree-cut With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T4 F[...]
-
Page 46
113 FX-301 DIMENSIONS (Unit: mm in ) 19.5 0.768 FT -P81X FT -H35-M2 Toothed lock washer " 8.5 " 0.335 [Stainless steel (SUS)] FT -H35-M2S6 FT -H20W -M1 FT -H20W -M2 FT -H20-M1 FT -H13-FM2 15 0.591 FT -Z802Y FT -L8Y FT -V8Y Thru-beam type fibers With FX-A T2 With FX-A T2 F ree-cut With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T3 [...]
-
Page 47
114 FX-301 DIMENSIONS (Unit: mm in ) FD-B8 F ree-cut FD-5 FD-FM2 FD-FM2S FD-FM2S4 FD-T80 FD-T40 FD-S80 FD-N8 FD-N4 FD-NFM2 Reflective type fibers With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T5 F ree-cut With FX-A T5 With FX-A T10 F ree-cut With FX-A T2 With FX-A T3 F ree-cut F ree-cut With FX-A T4 F ree-cut F ree-cut With FX-A T4 FD-NFM[...]
-
Page 48
115 FX-301 DIMENSIONS (Unit: mm in ) " 4 " 0.157 FD-R80 F ree-cut FD-V41 FD-SFM2SV2 FD-WKZ1 FD-W8 FD-W44 FD-WT8 FD-WS8 FD-WT4 FD-WG4 Reflective type fibers With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T3 F ree-cut With FX-A T5 F ree-cut F ree-cut With FX-A T4 With FX-A T4 With FX-A T3 F ree-cut F ree-cut With FX-A T4 F ree-cut [...]
-
Page 49
116 FX-301 DIMENSIONS (Unit: mm in ) FD-WL42 F ree-cut FD-WV42 FD-P80 12 0.472 FD-P60 FD-P50 FD-P40 FD-P2 FD-A15 FD-AFM2 FD-AFM2E Reflective type fibers With FX-A T4 With FX-A T5 With FX-A T2 With FX-A T3 With FX-A T6 F ree-cut F ree-cut F ree-cut F ree-cut With FX-A T4 With FX-A T5 With FX-A T4 With FX-A T3 With FX-A T3 With FX-A T6 F ree-cut F re[...]
-
Page 50
117 FX-301 DIMENSIONS (Unit: mm in ) FD-EG1 FD-EG2 With FX-A T2 With FX-A T2 With FX-A T2 With FX-A T5 With FX-A T2 With FX-A T2 FD-E12 ( " 3.2) ( " 0.126) Model No. tube (PVC) FD-E22 FD-EG3 15 0.591 15 0.591 FD-EN500S1 FD-ENM1S1 FD-L43 F ree-cut Details of sensing part Details of sensing part Details of sensing part Details of sensing pa[...]
-
Page 51
118 FX-301 DIMENSIONS (Unit: mm in ) FD-L41 F ree-cut FD-L42 With FX-A T4 With FX-A T4 With FX-A T3 With FX-A T2 With FX-A T4 With FX-A T4 With FX-A T6 F ree-cut FD-L4 F ree-cut FD-F41 FD-F91 FD-F4 FD-F9 F ree-cut FD-F8Y F ree-cut Toothed lock washer " 11 " 0.433 FD-P81X FD-G6X F ree-cut Details of sensing part Details of sensing part Ref[...]
-
Page 52
119 FX-301 DIMENSIONS (Unit: mm in ) FD-H35-M2 FD-H35-M2S6 FD-H20-M1 FD-H30-L32 FD-H20-21 FD-H35-20S FD-H18-L31 FD-H13-FM2 With FX-A T3 F ree-cut F ree-cut With FX-A T3 FD-6V FX-LE1 Details of sensing part Details of sensing part Details of sensing part Details of sensing part Details of sensing part Details of sensing part Details of sensing part [...]
-
Page 53
120 FX-301 DIMENSIONS (Unit: mm in ) FX-LE2 FX-SV1 Super-e xpansion lens (Optional) Side-view lens (Optional) FV -LE1 FV -BR1 Expansion lens (F or vacuum type fiber Optional ) Photo-terminal (For v acuum type fiber Optional) FT -J6 FX-MR1 Fiber at atmospheric side (For v acuum type fiber Optional) Pinpoint spot lens (Optional) FX-MR2 FX[...]
-
Page 54
121 FX-301 DIMENSIONS (Unit: mm in ) 16 0.630 MS-EX-3 FTP- FDP- Mounting brac ket f or FD-WKZ1 FB-1 FX-CT2 FX-A T2 FX-A T3 FX-A T4 FX-A T5 FX-A T6 Mounting brac ket f or FX-MR2 (Accessor y f or FX-MR2 ) Material: Br ass (Nickel plated) Material: SPCC-SD (Zinc chromate plated) FX-CT2 is not attached with the FT -NB8/N8/P80 or the FD-N8/N4/P8[...]
-
Page 55
FX-301-F Digital Fiber Sensor f or Leak Detection / Liquid Detection Fiber s Onl y Easy operation even for beginners! Optimum settings can be realized with simple operations 518 For use with leak detection or liquid detection fiber only Easy to operate with individual / collective teaching mode Easy maintenance, as main and sub units are identical [...]
-
Page 56
519 FX-301-F Wiring- and labor-sa ving design allows side- by-side configuration f or up to sixteen units Easy operation with MODE NA VI Simple operation with easy access to adv anced functions T wo s witches with distinct functions Only two s witches, the large jog s witch and the large MODE ke y , are required for operation. Depressing the large [...]
-
Page 57
520 FX-301-F ORDER GUIDE FD-F7 series, FT -F9 ser ies 12 to 24 V DC 10 % Ripple P-P 10 % or less Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) NPN open-collector transistor • Maximum sink current: 100 mA (50 mA, if[...]
-
Page 58
521 FX-301-F Symbols … D : Rev erse supply polarity protection diode Z D : Surge absor ption zener diode T r : NPN output transistor Symbols … D : Rev erse supply polarity protection diode Z D : Surge absor ption zener diode T r : PNP output transistor 08/2005[...]
-
Page 59
522 FX-301-F PRECA UTIONS FOR PROPER USE Mounting How to mount the amplifier Cascading amplifiers • Make sure that the po wer supply is off while cascading or removing the amplifiers. • Make sure to chec k the allow able ambient temperature, as it depends on the number of amplifiers connected in cascade. • In case two , or more, amplifiers ar[...]
-
Page 60
523 FX-301-F PRECA UTIONS FOR PROPER USE Individual teaching mode P ar t description • The sensitivity selection function is set to the automatic sensitivity setting ( ) at the time of factory shipment. In case sensitivity selection setting is done, mak e sure to carr y out ‘teaching’ after the sensitivity selection setting. • For the sensi[...]
-
Page 61
524 FX-301-F PRECA UTIONS FOR PROPER USE Press MODE ke y to light up MODE indicator / ADJ (yellow). T ur n Jog switch to the ‘ ’ side, to increase the threshold value . T ur n Jog switch to the ‘ ’ side, to decrease the threshold value . When Jog switch is pressed, the changed threshold value blinks 3 times and is confirmed. When MO[...]
-
Page 62
525 FX-301-F PRECA UTIONS FOR PROPER USE Press MODE ke y to light up MODE indicator / OUT (yellow). (Present output state is display ed.) When Jog switch is turned to the ‘ ’ side or ‘ ’ side, the output is compulsory changed to ON or OFF . Since the emitting element of the amplifier blinks, it is possib le to check the fiber connec[...]
-
Page 63
526 FX-301-F PRECA UTIONS FOR PROPER USE NO / NC selection function [Liquid (F9) mode only] • The NO / NC selection can be done by pressing the jog s witch f or 3 sec., or more, when Liquid (F9) mode ( ) has been set and MODE indicator / DISP (yello w) lights up. In case of Leak (F7) mode ( ), the display does not change to NO / NC selection func[...]
-
Page 64
527 FX-301-F 08/2005[...]
-
Page 65
FX-305 Digital Fiber Sensor Four-chemical emitting element Double coupling lens APC circuit N ew A dvanced sensor with V isible I ndicator Digital Fiber Sensor with 2 independent outputs 122 SERIES Industry first! Light-emitting amount selection function Stable sensing o ver long and shor t periods If the light-receiving le vel becomes saturated du[...]
-
Page 66
123 FX-305 SPECIFICA TIONS I/O CIRCUIT DIMENSIONS (Unit: mm in ) Amplifier FX-305 FX-305P 2.5 0.098 Digital display (Red) Jog switch MODE key 0.7 0.028 Output 1 operation indicator (Orange) Output 2 operation indicator (Orange) 8.3 0.327 27.8 1.094 7 0.276 36.5 1.437 64.5 2.539 Communication window 10.5 0.413 3.95 0.156 3.3 0.13 7 0.276 7 0.276 Bea[...]