Panasonic UJ30 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Panasonic UJ30, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Panasonic UJ30 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Panasonic UJ30. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Panasonic UJ30 should contain:
- informations concerning technical data of Panasonic UJ30
- name of the manufacturer and a year of construction of the Panasonic UJ30 item
- rules of operation, control and maintenance of the Panasonic UJ30 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Panasonic UJ30 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Panasonic UJ30, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Panasonic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Panasonic UJ30.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Panasonic UJ30 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User’s Manu al LED UV Curing Sy stem Aicure SPOT Type UJ30/35 Series 2011.9 | panasonic-ele ctric-works.net/sunx ARCT1F51 0E-2[...]

  • Page 2

    LED produ ct safety precautio ns ii LED Product Classificati on The light source of the LED head connected to this product i s classified as 3B und er the JIS C6802 “Saf ety of l aser products.” Max output: 78 0mW Wavel ength: 365±5 nm Class 3B L ED Product JIS C6802: 2005 Max output: 94 0mW Wavel ength: 385±5 nm Class 3B L ED Product JIS C68[...]

  • Page 3

    LED produ ct safety precautio ns iii Laser products Preventive safety measures for users (summ ary) [from JIS “Safety of laser products”] Classification Required item / Article Class 1 Clas s 1M Class 2 Class 2M Class 3R Class 3B Clas s 4 Laser safety manager 10.1 Not necessary , but it is recomm ended that o ne be appointed in t he case of ap [...]

  • Page 4

    LED produ ct safety precautio ns iv Safety fea tures This product is equipped with the following safety features, based on JIS C6802 “Safety of laser products.” ■ Remote interlock UV irradiation can be stopped by opening the INPUT terminal “INTERLOCK (11)” on the rear of the controller. It is shorted with a shorting bar as a factory defau[...]

  • Page 5

    LED produ ct safety precautio ns v Label s The LED irradiation warning labels (sho wn below specified by JIS C6802) shown below are attached to the LED heads before this product is shipped from the factory. Warning labels in Chinese th at comply with GB standards and those in English that comply with IEC/EN standard s are also included. ■ Warning[...]

  • Page 6

    Safety precautio ns vi The pu rpose of th e follo wing cau tion indications is to ensure the safe and correct use of this product, in order to protect users from injury and prevent property damage. The caution indications to prevent possible human injury and propert y damage caused by incorrect use are classified by “DANGER” and “WARNING” d[...]

  • Page 7

    Precautions f or use vii ■ General precaut ions ・ Never connect an y LED head, con nection cable, AC adap ter, or UV sensor to the main unit, other than those d esignated by Panasonic. Oth erwise, any failure, loss, or damage that may occur wil l not be covered un der warranty. ・ Never try to disass emble or modif y the product, or to alter i[...]

  • Page 8

    Precautions f or use viii ■ Setup ・ Check that the rubber feet of the produ ct are always horizontally level. Never inclin e the product, or position it on its side, or upside do wn. Otherwise, overheating ma y occur, resulting in f ailure and damage. ・ Never place anything on top or below the product, or obstru ct the ventilation openings in[...]

  • Page 9

    Precautions f or use ix ・ SELL ER SPECIFICALL Y DISCLAI MS ALL IMPLIED WA RRANTIES OF MERCHANT ABILITY AN D/OR FITNESS F OR A PARTICUL AR USE OR PURPOSE, AS WELL AS LI ABILITY FOR I NCIDENTAL , SPECIAL, I NDIRECT, CONSEQUEN TIAL OR OT HER DAMAGES R ELATING TO T HE PRODUCT. Product EOL (“end of life”) ・ Please understan d that product ion of[...]

  • Page 10

    x Contents 1 Fe atures of the ANU J 3000/3500 ....... ........ ......... ........ 1 2 Pro duct com ponents.................................................... 3 3 Par ts names a nd fun ctions ........................................... 4 4 I nstallatio n .................................................................. 6 4.1 I nstallatio n condi t[...]

  • Page 11

    1 Features of the ANUJ 300 0/350 0 1 The ANUJ 3000/3500 is an UV curing d evice that quickly hardens UV resins (inks, adhesives, and coatings) via irradiation with UV light from an LED light source. The focu sed app lication of UV radiation to UV resins coated on minute surfaces (2 t o 3 mm dia.) such as the lenses of CD, MD, and DVD players, an d [...]

  • Page 12

    Features of the AN UJ 300 0/3500 2 The ■ Universal des ign for ea sy operatio n Easy o peration has been achieved by the p roduct’ s universal design, including the large-sized colo r LED display with a high level of visibility and the operation switches located at op timal locations. After connectin g th e head, UV irradiation can be started s[...]

  • Page 13

    2 Part names and f unction s 3 Controller AC adapter 100 V (AC) power cable for use in Japan onl y Instruction Manual Optional parts (so ld separately) LED head Standard lens Connection cable x1[...]

  • Page 14

    3 Part names and f unction s 4 Front of the contro ller UV sensor (option) Rear of the controller AC adapter DC output indicator LED[...]

  • Page 15

    Part na mes and function s 5 Description Function Remark (1) EMISSI ON switch UV is irradiated and stopped by selected irradiating CH head. Red lamp is turned on during UV irradiation. (2) READY indicator Indicates that UV irradiation is enabled (re ady to start). (3) CH1-CH4 operation switch Selects the L ED head channels for irradiation . (4) CH1[...]

  • Page 16

    6 4 Installation Install and set up the product according to the following conditions. 4.1 Installation conditions 1) Ambient temp.: Controller: 0 to +35 °C Head: +5° to +35°C 2) Relative humidity: 30 to 85% (at 25°C, no condensation) 3) When setting up the controller, make sure that its rubber feet ar e horizontally level. 4) To prevent damage[...]

  • Page 17

    Installation 7 A NU J 6 4 2 8 A NU J 6 4 2 8 A NU J 6 4 2 8 A NU J 6 4 2 8 ( φ8mm) 0 50 0 1,00 0 1,50 0 2,00 0 2,50 0 3,00 0 3,50 0 4,00 0 -5 - 4 -3 - 2 -1 0 1 2 3 4 5 照射範囲 (mm ) UV強度 (mW/c m 2 ) WD=10 WD=15 WD=20 WD=25 WD=30 WD=40 WD=50 4 . 2 G e n e r a l g u i d e l i n e s fo r i r r a d i a t i o n d is t a n c e a n d[...]

  • Page 18

    Installation 8 Cylindrical lens data (typical characteristics) ■ Rod lens data (typical characteristics) ■ Side-view lens data (ty pical charac teristics) Side-view lens ANUJ6475S 長手方向 幅方向 0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000 -4 -3 -2 -1 0 1 2 3 4 照射範囲(mm) U V 強 度 (m?[...]

  • Page 19

    9 5 Getting started After connecting the necessary cords, lastly plug in the power cord. This section describes the steps up to turning on the power . 5.1 Hooking up the connection cable Plug the connection cable (for the LED head) into its connection port. Plug the female side of the connection cable into the ma in unit. P lugging in the wrong sid[...]

  • Page 20

    Getting started 10 Rear panel <Proced ure> 1. Plug in the co nnection cabl e. 2. Connect the LE D head to th e connection cable. 3. Remove the p rotective cap from the LED head . Set the LED jig in place. <Reference> Heat dissipation device (aluminium) (A metal fixture attached to the head) If the LED head is n ot fixed to a jig, th e L[...]

  • Page 21

    Getting started 1 1 5.3 Connecting the external contr ol signals The external con trol connectors on the b ack of the con troller (two blo cks of 12 pins) are removable. External control connectors (12 pin × 2) MINI COMBICON Plug 12P (Phoenix Contact M C 1.5/12-ST-3.5) (Osada OS-85-12P) Compatible wire (stranded) Tightening torque: 0.22 Nm to 0.25[...]

  • Page 22

    Getting started 12 5 . 4 C o n n e c t i n g t h e A C a da p t e r P l ug t h e c o n n e c t o r o f t h e s u p p li e d A C a da p t e r i n t o t h e A C a da p t e r c o n n e c t o r o n t h e r e a r p a n e l . T o e n s u r e t ha t t h e c on t r o l l e r i s c o m pl e t e l y d i s c o n n e c t e d f r om t h e p o w e r s u p p l y [...]

  • Page 23

    13 6 Operation modes 6 . 1 O p e r a t i o n m od e ( d e f a u l t m o d e w h e n po w e r i s t ur n e d o n) ■ Status check Displays in Operation mode Display Descriptions EMISSION switch. Pressing it will start irradiation. Stay s on during irradiation. READY Indicates that irradiation is ready to start. Stay s on while irradiation is ready [...]

  • Page 24

    Operation modes 14 ■ How to operate the controller 1) Setting irradiation conditions Setting the irradiation intensity and irradi ation time se parately for e ach of CH1 to CH4.  The The The The displayed displayed displayed displayed values values values values appl y apply apply apply to to to to th e the the the flashing flashing flashing f[...]

  • Page 25

    Operation modes 15 3) Continuous irradiation Irradiation using the EMISSION switch of the contro ller  The The The The displayed displayed displayed displayed values values values values appl y apply apply apply to to to to th e the the the flashing flashing flashing flashing channel. channel. channel. channel. (1) Starting irradiation 1. Select[...]

  • Page 26

    Operation modes 16 5) Display of head management information [Head temperature (°C or °F)] 1. With the display showing irradiation informat ion, press the MODE sw itch. 2. The head temperat ure is displaye d. * Fahrenheit values include a “.” (decimal po int). 3. Press t he CH switch to sw itch to other channels. [Display of head lifetime inf[...]

  • Page 27

    Operation modes 17 6 . 2 U V m e a s u r e m e n t a n d A u t o t u n i ng m o d e It is possible to make UV measureme nts and Auto tunings. * To use this mode it i s necessary to have a compatible UV sensor (o ption). ■ Operation 1) Measuring UV intensity (1) Connecting a UV sensor 1. While in oper ation mode, press the U V CHK switch. 2 . The [...]

  • Page 28

    Operation modes 18 2) Auto tuning (1) Switching to calibration mode 1. While in oper ation mode, press the U V CHK switch. 2. The intensity setting value (green) and inte nsity measureme nt value value (re d) are displayed. 3. Se lect the CH for UV intens ity measurement. 4. W hile the intensity setting value (green) and intensity measurement value[...]

  • Page 29

    Operation modes 19 6 . 3 D e fa u l t s e t t in g s m o d e This mode is used for the units (°C/°F) for head temperature readings, for switching betwee n READY/BUSY signal, and for setting the buzzer ON/OFF. * The default values are Celsius (°C) for temperature display, BUSY, and buzzer ON. [Default settings mode] 1. While pressing do wn the MO[...]

  • Page 30

    Operation modes 20 6 . 4 T i m i n g c h a r t 1) Batch irradiation: Heads selected (*1) with CH1 through 4 operatio n button in front of the controller are processed in batch irradiation mode. ・ Preparation of batch irradi ation: READY A ll is ON (*2) . ・ Batch irradiation start: Press EMISS ION button in front of th e controller or turn on ST[...]

  • Page 31

    Operation modes 21 ② Continuous (Con) batch irradiation[...]

  • Page 32

    Operation modes 22 2) Individual irradiation When ST AR T 1~4 input on the back side of the co ntroller is turned on, individual CH is irradiated. ・ Preparation of individual ir radiation: READY 1~4 applicable to each CH is ON *2) ・ Individu al start: T urn on ST AR T 1~4 input signals on the backside of the controller . ・ Batch stop: Press E[...]

  • Page 33

    Operation modes 23 *1) It is not possible to select a particular channel unless it has an LED head connected to it. *2) Conditions under which the signals below are set to ON. - READY ALL: ON when CHs are selected on the front p anel of the controller, and all selected channels are ready *3) for irradiation. - READY1-4: ON when the corresponding CH[...]

  • Page 34

    24 W arning W arning W arning W arning 7 External control 7 . 1 E x t e r na l in p u t / o ut pu t c o n t r ol ■ External control connectors (12 pin × 2) MINI COMBICON Plug 12P (PHOENIX CONTACT: MC 1.5/12-S T-3.5) (Osada: OS-85-12P) Compatible wiring (stranded) Tightening torque: 0.22 to 0.25 Nm Precautions for wiring ・ Carefully strip the c[...]

  • Page 35

    External control 25 Output Specifica tion ・ Rated load voltage: 5 V DC to 28 V DC ・ Max. load curr ent: 100 mA (p er 1 output) When 5 V inter nal voltage is u sed, set the total o f maximum load c urrent to less than 250mA. ・ Maximum voltage d rop is less than 0 .9 V when output is given. ■ Product type switching table Type No . Pin No.7 Pi[...]

  • Page 36

    External control 26 7 . 2 S e r i a l c o m m un i c a t i o n c o n t r o l ■ RS-232C ter minal specificatio ns ( D-Sub 9-pin ) D-sub 9-pin connector (male pins) (JAE: DELC-J9PAF-10L9E) [Connection cable specifications] For the cable connector use a D-sub 9-pin conn ector (fema le pins). Cable (shielded). UJ30/35 Controller side Signal Name [...]

  • Page 37

    External control 27 W arning W arning W arning W arning ■ Commands and responses ・ Instructions sent to the controller are called commands. ・ Messages returned from the controller are called responses. ・ The communications are two-way . (When a command is sent, a response is always returned.) ・ Data is sent in ASCII format. ・ When a res[...]

  • Page 38

    External control 28 ■ Control commands ■ Support commands An instruction for the controller is called a “comm and,” while the message sent back from th e controller is a “response.” The commands below marked by ○ are suppo rted. If an unsupported command is received by the controller it returns an error response including a “NOT sup[...]

  • Page 39

    External control 29 ■ Data areas[...]

  • Page 40

    External control 30 7 . 3 C o m m un i c a t i o n s a d d r e s s m a p ■ A d d r e s s f o r r e a d i ng ( 1 a d d r e s s = 16 b it s )[...]

  • Page 41

    External control 31[...]

  • Page 42

    External control 32[...]

  • Page 43

    External control 33[...]

  • Page 44

    External control 34 ■ A d dr e s s f o r w r i t i n g ( “ 1 a d d r e s s = 1 6 b i t ” ) … New settings take effect when the address o f the data setti ng is executed. (The settings are saved to memory when po wer is turned O FF.) To save new setti ngs, re write to memory and the n execute th e addr ess. Note: Me mory can be re written up[...]

  • Page 45

    External control 35[...]

  • Page 46

    External control 36[...]

  • Page 47

    External control 37[...]

  • Page 48

    External control 38 ■ WRIT E procedure ・ Communication da ta is accepted at each ad dress, and the a ccepted data w ill be confirm ed b y the execution o f the data setti ng addre ss and data memory address. - Data confirmed by the setting addr ess will be written to memory when the controller is powered OFF. Data confirmed by the me mory addre[...]

  • Page 49

    External control 39 7 . 4 S e t u p t o o l a pp l i c a t i o n f o r U J 3 5 ■ Operation from a PC ・ Application can be downloaded from the web. ・ Compatible with Windows XP, Windows Vista, and Windows 7.[...]

  • Page 50

    External control 40 1. Open the Aicure UJ35 application 2. Select initial settings ・ Select the port for UJ35 controller connection (default setting is COM 1) 3. Using the Menu Bar 1) File (F) ・ Open (O) … Opens a UJ35 data file (*.ai3). ・ New (N) Cancels current settings to create new settings. ・ Save (S) Overwrites existing data file wi[...]

  • Page 51

    External control 41 4. Using the operation setting screen [Settings 1] 1) Set UJ – Selects T ype from 0 to 7 (does not switch CH selection). *During T ype selection T ype Change is highlighted. ・ Read Reads t he current T ype setting from UJ35 controller into computer . ・ W rite Uploads current T ype from computer to UJ35 controller . ・ Can[...]

  • Page 52

    External control 42 4 ) “Cum ulative irradiation time (×100hrs)”… To set the cumulative irradiation time (*During setting “Cumulative irradiation ti me (×100hrs)” is highlighted.) ・ Read Reads the current val ue of cumulative irradiatio n time from the UJ35 co ntroller into the PC. ・ W rite Uploads the current cumulative irradiati[...]

  • Page 53

    External control 43 2) “Replacement time (×100hrs)”… To set the LED replacement time (* While changing replacement time settings, “Replacement time (×100h rs)” is highlighted. ・ Read Reads the current replacement time setting from the UJ35 con troller into the PC. ・ W rite Uploads the current replacem ent settin g from the PC to the[...]

  • Page 54

    External control 44 6. Using the AUTO screen (only available in onlin e mode) … Displays all UJ35 controller informa tion in real time. … Enables irradiation START/STOP and emergency STOP control from computer. ・ [TYPE] Shows current TYPE (0–7). ・ [STEP] Du ring irradiation, current STEP is displayed. ・ [TIME(s)] During irradiation, cou[...]

  • Page 55

    External control 45 7. Using the UV.CHK screen (only available in on line mode). … Displays all UJ35 controller information in real time. … Enables measurement calibration of optional UV sensor and set UV strength values. ・ LED status for each CH diff erentiated by color ・ If an error occurs, an error number is displayed ・ Panel showing e[...]

  • Page 56

    8 Warning indications 46 In th e event of an error d uring irradiation, a warning will be d isplayed on th e display panel of the con troller (in operation mode). ■ Temperature warning When the LED head temperature reaches the warning level during irradi ation in operation mode, “TEMP ” (units indicator) will start to flash, and the LED light[...]

  • Page 57

    Warning indicatio ns 47 ■ Error codes When an error occurs, the three-digit display will indicate the error code. Display Error name Error description E00 Interlock emergency stop The interlock co ntact was o pened during irradiation. CH1-4 E10 Connection error The LED head was disconnect ed. CH1-4 E20 LED break error A circui t brea k was d etec[...]

  • Page 58

    9 Safety measures 48 9 . 1 S a fe t y c ir c u i t Aicure UJ35 is equipped with a safety circuit, which function s as follows, in case of a malfunction or accident. 1) If the cable b etween th e LED head and the control ler i s broken, an error signal w ill be output and an error screen displayed. 2) If the LED head is short-circuited, an error sig[...]

  • Page 59

    10 Specification s 49 1 0 . 1 O u t l i n e o f s p e c i fi c a t i o ns ■ C o nt r o l l e r s pe c i f i c a t i o n s Item ANUJ3000 A NUJ350 0 No. of connected heads 1-4 heads UV sensor connection Not supported 1 (special UV sensor for A NUJ3800, sold separately) UV irradiation Simple mode, 1 pattern irradiation All heads together/separately [...]

  • Page 60

    Specification s 50 High-power head Item ANUJ6170 ・ ANUJ6171 Spot diameter φ 3mm φ 4 mm φ 6mm φ 8 mm φ 10mm Lenses Le ns model ANUJ6423 ANUJ6424 ANUJ6426 ANUJ6428 ANUJ6420 UV intensity (mW/cm 2 ) 10170 8610 3910 2010 710 Working distance 10mm 12mm 20 mm 25 mm 30mm Light source Max. output: 780 mW, wavelength: 365±5 nm, Class 3B, LED Estimate[...]

  • Page 61

    1 1 Dimensions 51 High-power head Item ANUJ6160 ・ ANUJ6161 Spot diameter φ 3mm φ 4 mm φ 6mm φ 8 mm φ 10mm Lenses Le ns model ANUJ6423 ANUJ6424 ANUJ6426 ANUJ6428 ANUJ6420 UV intensity (mW/cm 2 ) 8000 6850 2990 1740 580 Working distance 10mm 12mm 20 mm 25 mm 30mm Light source Max. output: 660 mW, wavelength: 365±5 nm, Class 3B, LED Estimated [...]

  • Page 62

    Specification s 52 ■ UV sensor specifications Item ANUJ3800 High range 0 to 49.9 W/cm 2 (min. reading 0.1 W/cm 2 ) UV intensity measurement range Low range 0 to 9.99 W/cm 2 (min. reading 0.01 W/cm 2 ) Measurement precision ±5% (+5 to +35°C) ±1% (at 25°C, repeatability) Data communication RS-422 level communication, proprietary[...]

  • Page 63

    1 1 Dimensions 53 Mounting bracket ANUJ 680 4 UV SENSOR ANUJ 380 0 LED head ANUJ 617 2/6162 Connection cable ANUJ 622 0 Standard l ens Rod le ns /Sylindrical lens A NUJ6467 ANUJ 646 7 Side view lens Cable length Cable length ANUJ 617 3/6163 ANUJ 617 0/6174/6160/616 4 ANUJ 617 1/6175/6161/616 5 M6 (5mm D) 2-M4 (5mm D)[...]

  • Page 64

    12 Option and spare parts list 54 1)Controller Name Description Product number UJ30 controller 4 head connection (in cl. AC adapter) A NUJ30 00 UJ35 controller 4 head connection (incl. AC adapter) RS- 232C communication, supports UV senso r (specially for UJ35) ANUJ3500 2) Heads Name Description Product number φ 12×L50 mm head (cable length[...]

  • Page 65

    Option and spare parts list 55 5) Options and spare parts Name Description Product number UV sensor Sp ecial UV sensor for UJ35 controller ANUJ3800 100 to 240 V AC adapter AC adapter (Included cable is 100 V AC) ANUJ6802 200 V AC power cable 200 V power cable for ANUJ6802 ANUJ680 3 Mounting bracket Split type ANUJ6804 Goggles UV protective gogg[...]

  • Page 66

    12 Option and spare parts list 56 W arning W arning W arning W arning 1 2 . 2 H o w t o r e p l a c e t he l e n s u n i t 1) Rotate the lens unit to attach it to the LED head. (Tightening torque: 0.2 Nm) 2) Stick on the included seal to prevent looseness. ・ When attaching a lens unit, take care to prevent any d irt o r other foreign sub [...]

  • Page 67

    13 Troub leshooting 57 Symptoms Chec ks/Remedies LED does not irrad iate. Did you select the target channel for the product t ype? (When selected, the channel switch is lit or flash ing.) → Sele ct the target cha nnel when setting the product type. If the targe t channel is selected but does not irradiate, check i f the i rradiati on time is set [...]

  • Page 68

    Manual revision history 58 Manual No. Issued Revision Details ARCT1F510E 2010.05 I nitial version ARCT1F510E-1 2010.10 2 nd edition ARCT1F510E-2 201 1.9 3 rd edition[...]

  • Page 69

    Please contact .. ........ ASCT1F510E-2 Specifications are subject to change without noti ce. Printed in Japan[...]