Paradyne 5216 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Paradyne 5216, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Paradyne 5216 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Paradyne 5216. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Paradyne 5216 should contain:
- informations concerning technical data of Paradyne 5216
- name of the manufacturer and a year of construction of the Paradyne 5216 item
- rules of operation, control and maintenance of the Paradyne 5216 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Paradyne 5216 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Paradyne 5216, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Paradyne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Paradyne 5216.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Paradyne 5216 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TM 1 Hotwire 5216 Remote T ermination Unit (RTU) Customer Premises Installation Instructions Document Number 5216-A2-GN10-10 February 1998 Before Y ou Begin An optional POTS (Plain Old T elephone Service) splitter is available for the 5216 RTU. When a POTS splitter is installed, the telephone and 5216 RADSL (Rate Adaptive Digital Subscriber Line) R[...]

  • Page 2

    2 Package Checklist V erify that your package contains the following: - Model 5216 Remote T ermination Unit (RTU) - DSL interface cable with RJ1 1 modular plugs - Power cord with power transformer - T wo ferrite chokes - W arranty card Refer to Cables & Connectors , page 13, for standard pin numbers. What Does the Hotwire R TU Do? The 5216 RTU [...]

  • Page 3

    3 When a POTS splitter is used at both ends of the local loop, wiring is connected: H From the demarcation point to the CP POTS splitter , and H From the demarcation point to the DSL jack. 97-15608 Punchdown Block or NID DSL Jack RT U New Wiring Connections Existing Wir ing (PO TS) Customer Premises (CP) DSL Ethernet Crossov er Cable Central Office[...]

  • Page 4

    4 DSL Access without a POTS Splitter When the 5216 RTU is installed without a POTS splitter , a second telephone wiring pair is needed for DSL access. 97-15609 Punchdown Block or NID DSL Jack RT U Customer Premises (CP) PO TS DSL Ethernet Crossov er Cable Central Office (CO) Demarcation P oint Local Loop New Wiring Connections Existing Wir ing (PO [...]

  • Page 5

    5 Installing the DSL Access Wiring The local loop terminates at the punchdown block or NID. Wiring must be connected from the customer premises side of the punchdown block or the NID to the DSL jack. T ypically , the punchdown block is installed in commercial locations and the NID is installed in residential locations. " Procedur e 1. Access t[...]

  • Page 6

    6 Green (T1) and red (R1) are the standard wiring colors used in the next two illustrations. In the following example, a NID is used without a POTS splitter . It includes an existing POTS line and a second pair installed for DSL access. The POTS pair for the existing POTS line wiring does not need to be disconnected unless a POTS splitter is going [...]

  • Page 7

    7 2. Locate the DSL pair of T1/R1 connectors on the customer premises side of the NID or punchdown block. Attach the wiring that will be connected to the DSL jack. T ighten both terminal screws with a flat-blade screwdriver . DSL/PO TS Access from Local Loop Wiring to DSL Jac k T elephone Network Interface Device (NID) Ground Tip T1 (Green) Ring R1[...]

  • Page 8

    8 DSL Jack Installation The 5216 RTU connects to the local loop via wiring from the demarcation point to an RJ1 1 wall jack. The DSL twisted-pair wiring from the local loop terminates at a new or existing wall jack. It may be necessary to install a standard single RJ1 1 jack or replace a single jack with a double RJ1 1 jack. The RJ1 1 6-pin jack us[...]

  • Page 9

    9 Installing the R TU Place the 5216 RTU on a flat surface with clearance for the rear connectors. " Procedur e 1. Use the RJ1 1 6-pin cable for the DSL connection. Insert one end of the cable into the jack labeled DSL. Insert the other end into the wall jack labeled DSL. 97-15300-01 DSL Jack POWER ETHERNET DSL Hotwire RTU 2. Use an 8-pin Ethe[...]

  • Page 10

    496-14952 97-15303c Ethernet Line PO WER ETHERNET DSL Hotwire RTU F err ite Choke 10 3. Place the large ferrite choke on the Ethernet cable as closely as possible to the RTU. Pass the Ethernet cable through the ferrite choke twice, creating a loop as shown. 4. Close the two halves around the cable and snap the ferrite choke shut. Press down on the [...]

  • Page 11

    11 6. Close the two halves around the cable and snap the ferrite choke shut. Press down on the plastic latch to secure the ferrite choke in place around the cable. 7. Plug the transformer into an AC outlet. The RTU hardware installation is now complete. When the power cord is installed, the RTU goes through a power-on self-test. Power -On When powe[...]

  • Page 12

    12 LED Status Condition DSL Blinking ON OFF RTU is establishing the DSL link. The LED blinks on and off about five times per second. The DSL link is now active and ready to transmit and receive data. The DSL link has not been established. ETHERNET ON OFF The Ethernet 10BaseT connection to the end-user system is active. No Ethernet 10BaseT device is[...]

  • Page 13

    97-15304 6- P i n RJ 1 1 Pl ug DS L Li ne Pi n #1 Pi n #6 13 LED Symptom Action DSL and Ethernet LEDs are on and there is no data transmission. The DSL link and the Ethernet link have been established. If the problem continues, contact the NSP . Ethernet LED is off. V erify that the Ethernet 10BaseT cable is securely installed at both ends, and tha[...]

  • Page 14

    14 H The Ethernet interface crossover cable connector uses an 8-pin, non-keyed modular plug. 97-15305 8- P i n Pl u g E t he r ne t Ca bl e Pi n #1 Pi n #8 10BaseT TX D + 10BaseT TX D  10BaseT R X D + No t Us ed No t Us ed 10BaseT R X D  No t Us ed No t Us ed 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 10BaseT TX D + 10BaseT TX D  10BaseT R X D + No t[...]

  • Page 15

    15 Model 5216 R TU T echnical Specifications Item Specification * Height x Width x Depth 1.35 ″ x 6.00 ″ x 8.75 ″ (3.43 cm x 15.35 cm x 22.23 cm) Weight 1 lb. 1 oz. (0.48 kg) Power Class 2 T ransformer normal service input voltage range Input: 100 V ac, 50 Hz; 120 V ac, 60 Hz; or 230 V ac, 50/60 Hz Output: 15 Vdc nominal (+ 10%), minimum 0.6A[...]

  • Page 16

    16 Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. T o ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 3. Do n[...]

  • Page 17

    17 CE Marking When the product is marked with the CE mark on the equipment label, this demonstrates full compliance with the following European Directives: H Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within states relating to [...]

  • Page 18

    18 Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules. This compliance information statement pertains to the following products: T rade Name: Hotwire Model Number: 5216-A2-200 This device complies with Part 15 of the FCC Rules. Operat[...]

  • Page 19

    19 EMI W arnings ! W ARNING: T o Users of Digital Apparatus in Canada: This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe B respecte toutes les exigences du règlement sur le matérial brouilleur du Canada. Notice to Users of the Canadian T elephone [...]

  • Page 20

    20 W arranty , Sales, and Service Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty , sales, service, repair , installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the fol[...]