The rules should oblige the seller to give the purchaser an operating instrucion of Paradyne SLV 9128, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Paradyne SLV 9128 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Paradyne SLV 9128. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Paradyne SLV 9128 should contain:
- informations concerning technical data of Paradyne SLV 9128
- name of the manufacturer and a year of construction of the Paradyne SLV 9128 item
- rules of operation, control and maintenance of the Paradyne SLV 9128 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Paradyne SLV 9128 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Paradyne SLV 9128, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Paradyne service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Paradyne SLV 9128.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Paradyne SLV 9128 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 FrameSaver R SL V 9128 Quick Reference Document Number 9128-A2-GL10-40 May 2000 Product Documentation on the W orld Wide W eb We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain competitive price[...]

  • Page 2

    2 00-16722a Menu Hierar ch y Status System and T est Status LMI Reported DLCIs PVC Connection Status Timeslot Assignment Status DBM Interface Status IP Routing T able Perf ormance Statistics T rap Event Log Display LEDs and Control Leads Identity Identity • System • NAM • DBM LMI Reported DLCIs • DLCI • Status • CIR (bps) PVC Connection[...]

  • Page 3

    3 MAIN MENU Status T est Configuration Auto-Configur ation Control Easy Install Auto-Configuration • Fr ame Relay Discov ery Mode • Automatic Circuit Remov al • Automatic Backup Configuration 00-16728b MAIN MENU Status T est Configuration Auto-Configuration Control Easy Install System Information • Device Name • System Name, Location, Con[...]

  • Page 4

    4 Configuration Option Summaries This section summarizes the configuration options accessed when you select Configuration from the Main Menu. H System H Physical (Network, Data Port, and ISDN) H ISDN (Link Profiles) H DSX-1 H T ime Slot Assignment — Frame Relay Network Assignments — DSX-1 to Network Assignments — Sync Data Port Assignments H [...]

  • Page 5

    5 Frame Relay and LMI Select Frame Relay and LMI to configure the general frame relay options for the system. Frame Relay and LMI Configuration Option Settings Default in [ Bold ] LMI Behavior [ Independent ], Port-1_Follows_Net1-FR1, Port-2_Follows_Net1-FR1, All_Ports_Follow_Net1-FR1 Net1-FR1_Follows_Port-1, Net1-FR1_Follows_Port-2, Port-1_Codepen[...]

  • Page 6

    6 General Select General to configure a timeout period and duration for user-initiated loopbacks and pattern tests, a primary and secondary clock source for the system, and a system alarm relay . General Configuration Option Settings Default in [ Bold ] T est T imeout [ Enable ], Disable T est Duration (min) 1 – 120 [ 10 ] Primary Clock Source [ [...]

  • Page 7

    7 Data Ports Select Data Ports, then Physical to configure physical characteristics for the port connected to the DTE. Data Ports Configuration Option Settings Default in [ Bold ] Port Status [ Enable ], Disable Port Use (Port-2 only) [ Frame Relay ], Synchronous Data For Port-1 or when Port Use is set to Frame Relay on Port-2: Max Port Rate (Kbps)[...]

  • Page 8

    8 ISDN Select ISDN, then Physical to configure physical characteristics for the ISDN interface if an ISDN DBM is installed. The following table shows the configuration options for an ISDN BRI DBM. ISDN BRI Configuration Option Settings Default in [ Bold ] Interface Status Enable, [ Disable ] Originate or Answer [ Originate ], Answer Service Profile[...]

  • Page 9

    9 ISDN Link Profiles Select ISDN, then Link Profiles to configure the ISDN Link Profiles. Link Profiles Configuration Option Settings Default in [ Bold ] Link Name ASCII text entry , [ HQ_Site ] Link Status Auto, [ Disable ] Outbound Phone Number 0 – 9, * , # , <space>, _ , – , ), or ( Inbound Calling ID 1 or 2 0 – 9 Maximum Link Rate ([...]

  • Page 10

    10 Time Slot Assignment Select T ime Slot Assignment to make cross-connection assignments. Select Frame Relay Network Assignments to assign DS0s on the T1 network interface(s) for frame relay links. Frame Relay-to-Network Interface Time Slot Assignment Network Channel Settings Default in [ Bold ] T ime Slot Discovery [ Enable ], Disable N0 1 – N2[...]

  • Page 11

    11 Frame Relay Select Frame Relay to configure the Frame Relay characteristics of the following interfaces: H Network H Data Ports Frame Relay Configuration Option Settings Default in [ Bold ] LMI Protocol lnitialize_From_Net1FR1, Initialize_From_Interface, Auto_On_LMI_Fail, Standard, Annex-A, Annex-D [ lnitialize_From_Interface ] for a data port l[...]

  • Page 12

    12 DLCI Records Select DLCI Records to manually configure DLCI records for each interface. The Auto-Configuration feature provides automatic configuration of DLCI records. Select DLCI Records to configure the DLCI Records for the following interfaces: H Network H Data Port H ISDN The Auto-Configuration feature provides automatic DLCI record configu[...]

  • Page 13

    13 PVC Connections Select PVC Connections to manually configure the logical connections between the selected interface and the data ports. The Auto-Configuration feature provides automatic configuration of PVC connections. PVC Connections Configuration Option Settings Default in [ Bold ] Source Link Port- n , ISDN Link Name , Net1-FR1 Source DLCI 1[...]

  • Page 14

    14 Node IP Select Node IP to configure support of the IP communication network. Node IP Configuration Option Settings Default in [ Bold ] Node IP Address 001.000.000.000 – 223.255.255.255, [ Clear ] Node Subnet Mask [ 000.000.000.000 ] – 255.255.255.255, Clear Default IP Destination [ None ], Modem, COM, PVCname TS Access Management Link [ None[...]

  • Page 15

    15 General SNMP Management Select General SNMP Management to configure the FrameSaver unit so it can be managed as an SNMP agent. General SNMP Management Configuration Option Settings Default in [ Bold ] SNMP Management [ Enable ], Disable Community Name 1 A SC II text entry , [ Public ], Clear Name 1 Access Read, [ Read/W rite ] Community Name 2 A[...]

  • Page 16

    16 SNMP NMS Security Select SNMP NMS Security to configure access to the unit. SNMP NMS Security Configuration Option Settings Default in [ Bold ] NMS IP V alidation Enable, [ Disable ] Number of Managers [ 1 ] – 10 NMS n IP Address 001.000.000.000 – 223.255.255.255, [ Clear ] Access T ype [ Read ], Read/Write SNMP T raps Select SNMP T raps to [...]

  • Page 17

    17 Communication Port Select Communication Port to configure the FrameSaver unit ’ s COM port. Communication Port Configuration Option Settings Default in [ Bold ] Port Use [ T erminal ], Net Link When Port Use is set to T erminal: Data Rate (Kbps) 9.6, 14.4, [ 19.2 ], 28.8, 38.4, 57.6, 1 15.2 Character Length 7, [ 8 ] Parity [ None ], Even, Odd [...]

  • Page 18

    18 Modem Port Select Modem Port to configure the FrameSaver unit ’ s Modem port. Modem Port Configuration Option Settings Default in [ Bold ] Port Use [ T erminal ], Net Link When Port Use is set to T erminal: Dial-In Access [ Enable ], Disable Login Required Enable, [ Disable ] Port Access Level [ Level-1 ], Level-2, Level-3 Inactivity T imeout [...]

  • Page 19

    19 W arranty , Sales, Service, and T raining Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty , sales, service, repair , installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one[...]