Go to page of
Similar user manuals
-
Network Card
Patton electronic MODEL 1012AR
5 pages 0.03 mb -
Network Card
Patton electronic SN4900
30 pages 3.66 mb -
Network Card
Patton electronic 3056
9 pages 0.2 mb -
Network Card
Patton electronic 1052
20 pages 0.38 mb -
Network Card
Patton electronic 1007
5 pages 0.04 mb -
Network Card
Patton electronic 2085
20 pages 0.46 mb -
Network Card
Patton electronic SN455X
30 pages 3.66 mb -
Network Card
Patton electronic 1092A
19 pages 0.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Patton electronic 1060 AC Powered, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Patton electronic 1060 AC Powered one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Patton electronic 1060 AC Powered. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Patton electronic 1060 AC Powered should contain:
- informations concerning technical data of Patton electronic 1060 AC Powered
- name of the manufacturer and a year of construction of the Patton electronic 1060 AC Powered item
- rules of operation, control and maintenance of the Patton electronic 1060 AC Powered item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Patton electronic 1060 AC Powered alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Patton electronic 1060 AC Powered, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Patton electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Patton electronic 1060 AC Powered.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Patton electronic 1060 AC Powered item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
USER MANUAL MODEL 1060 AC Powered, Asynchronous Short Range Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com Part #07M1060-C Doc. #05801 1C Revised 1 1/3/97 CERTIFIED An ISO-9001 Certified Company Dear V alued Customer , Thank you for purchasing Patton Electronics products! W e do appreciate your business. I[...]
-
Page 2
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1060 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized [...]
-
Page 3
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Y ear parts and labor . If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics T echnical Support at (301[...]
-
Page 4
Control Input (C in ): The Control Input signal is used by the local Model 1060 as an input signal to activate its transmitter (“Enabled” settings) and allow data transmission to the remote device. This is required for half-duplex/ switched-carrier environments as well as in hardware flow control applications. In the “Disabled” settings, th[...]
-
Page 5
4.0 INSTALLATION The Model 1060 is easy to install. After configuring the DIP switches and DCE/DTE switches, connect the two twisted pairs using one of two methods: terminal blocks or RJ-1 1 jack. Figure 2 (below) shows the location of the terminal blocks and RJ-1 1 jack, as well as the female DB-25, on the rear of the Model 1060. Figure 2. Rear vi[...]
-
Page 6
4.2 WIRING FOR MUL TIPOINT CIRCUITS The Model 1060 supports multi-point applications using either a star or daisy chain topology . Both topologies require special wiring, as well as specific DIP switch settings for master and slave units. 4.2.1 DAISY CHAIN TOPOLOGY Using a daisy chain topology , you may connect as many as 10 Model 1060s together in[...]
-
Page 7
5.2.2 REMOTE ANALOG LOOP The second test mode is Remote Analog Loop. T o enter this mode, set one of the Model 1060s (local) in test mode by depressing the "Loopback T est" switch. Any characters sent from the remote 1060 will be returned to it (see Figure 5). If no characters are echoed back, check the wiring between the two Model 1060s.[...]
-
Page 8
14 13 APPENDIX A P A TTON MODEL 1060 SPECIFICA TIONS T ransmission Format : Asynchronous T ransmission Line : 19 to 26 A WG twisted pair Range : (See table on page 14) Serial Interface : EIA RS-232 (CCITT V .24), DB-25 female T wisted Pair Interface : T erminal blocks, RJ-1 1 jack Data Rates : 0 - 1 15,200 bps Applications : Point-to-point or multi[...]
-
Page 9
15 16 APPENDIX C P A TTON MODEL 1060 INTERF ACE PIN ASSIGNMENTS 1- (FG) Frame Ground 2- (TD) T ransmit Data T o Model 1060 3- (RD) Receive Data From Model 1060 4- (RTS) Request to Send T o Model 1060 5- (CTS) Clear to Send From Model 1060 6- (DSR) Data Set Ready From Model 1060 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect From Model 1060 1 1-[...]
-
Page 10
17 18 APPENDIX E TROUBLESHOOTING SYMPTOM PROBLEM SOLUTION "TD" and "RD" LEDs indicate activity , but units will not communicate or data is garbled "TD" and "RD" LEDs indicate activity , but "CD" LED is unlit or red (should be green) Occasional data errors 1. Improper RS-232 wiring 2. Improper twiste[...]