Go to page of
Similar user manuals
-
Marine Battery
Patton electronic 2039
16 pages 1.27 mb -
Marine Battery
Patton electronic 222N9
16 pages 0.4 mb -
Marine Battery
Patton electronic RS-449/422 to V.35
6 pages 0.06 mb -
Marine Battery
Patton electronic 2017P RS-232 to 20mA
7 pages 0.17 mb -
Marine Battery
Patton electronic 2094
20 pages 0.38 mb -
Marine Battery
Patton electronic 2035
16 pages 1.27 mb -
Marine Battery
Patton electronic 2035-25M
16 pages 1.27 mb -
Marine Battery
Patton electronic 2017P60 RS-232 to 60mA
7 pages 0.17 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Patton electronic 2094, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Patton electronic 2094 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Patton electronic 2094. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Patton electronic 2094 should contain:
- informations concerning technical data of Patton electronic 2094
- name of the manufacturer and a year of construction of the Patton electronic 2094 item
- rules of operation, control and maintenance of the Patton electronic 2094 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Patton electronic 2094 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Patton electronic 2094, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Patton electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Patton electronic 2094.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Patton electronic 2094 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
USER MANUAL MODEL 2094 V .35 to E1/Fractional E1 Converter SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com P ar t# 07M2094-UM Doc# 08605U2-004, Re v . B Re vised 10/25/06 An ISO-9001 Certified Company Notes __________________________________________ __________________________________________ _____________________[...]
-
Page 2
P A TTON MODEL 2094 T ABLE OF CONTENTS Section Page 1.0 General Information ...............................................................2 1.1 W arranty Statement 1.2 Radio and TV Interference 1.3 CE Notice 1.4 Service Information 2.0 General Information ............................................................5 2.1 Features 2.2 General Produc[...]
-
Page 3
1.4 SERVICE INFORMA TION All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Support at: tel: (301) 975-1007 ; email: support@pa[...]
-
Page 4
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed for One Y ear parts and labor . If any questions arise during installa- tion or use of the unit, contact Patton Electronics T echnical Services at (301) 975-1007. 2.1 FEA TURES • T ermin[...]
-
Page 5
Switch SW1: Line Coding Use Switch SW1 to control the Network Line Coding options. Set these options to be the same as the Line Coding given to you by your Service Provider . If you are using two Model 2094s together as short range modems, set both units to HDB3. SW4 Line Framing & Coding Off HDB3 On AMI Line Coding Options: High Density Bipola[...]
-
Page 6
CLOCK MODES Network Clock T ransmitter timing is derived from the received line signal. Internal Clock T ransmitter clock is derived from an internal clock source. External Clock T ransmitter timing is derived from the local DTE device. V alid only in unframed mode. Note: When using the 2094 as a high-speed short range modem, one unit of the link m[...]
-
Page 7
NOTE: When the data rate is set to 2.048Mb/s, then the unit is forced into G.703 mode, and it transmits user data on all 32 times- lots. There is no framing information; therefore, the CAS MF (SW2) switch is ignored. SW3 is defaulted to clock mode. In all other rate settings, the unit employs G.704 framing; TS0 is reserved for signaling. 3.2 SOFTW [...]
-
Page 8
3.2.1 Introduction to Main Menu After entering the password, you may access all of the system’s functions and parameters. The Main Menu looks like this: HELPFUL HINTS 1. T o make a selection, key the highlighted letter that corre- sponds to a menu selection. 2. T o execute the selection, type [Enter/CR] 3. Select g Save Changes from Main Menu aft[...]
-
Page 9
3.2.2 System Configuration The System Configuration menu looks like this: The System Configuration options are described below: Line Format: G.703 (default) Options: G.703, G.704 G.703: G.703 is unframed, 2.048Mb/s. In this case, the DTE rate is equal to the line rate at the network interface (NI). CAS MF and CRC-4 are disabled. G.704: G.704 reserv[...]
-
Page 10
Clocking : Network (default) Options: Network, Internal, External Network: This is the most commonly used setting when connect- ing to a carrier ’s network. In this mode, the unit recovers the clock from the received signal and uses it to transmit data. In this way the unit remains synchronized to a master clock. In campus applications, one of th[...]
-
Page 11
3.2.3 System Diagnostics The System Diagnostics/Statistics screen looks like this: NOTE: This screen is updated once per second. The System Diagnostics/Statistics options and functions are described below . Local Loop Idle (default) The Local Loop is a bi-lateral loopback in which the data from the local DTE and the data from the remote unit are lo[...]
-
Page 12
22 21 Remote Loop Idle (default) The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 2094s, as well as the communica- tion link between them. Data from the local DTE is sent across the entire communication circuit and looped back to the local DTE. The Model 2094 Initiating a RDL can be in one of the foll[...]
-
Page 13
23 24 Use this option to select the test pattern used to test the link. NI ST A TUS The Network interface (NI) status is shown in the middle of the Diagnostics/Statistics screen. The brackets are empty when the link is operating normally . Only one error message is provided Receiver Carrier Loss [RCL] occurs when 255 consecutive zeros have been det[...]
-
Page 14
25 26 Loop Timeout The Loop T imeout setting can be set to one of the following: 00:05 = five minutes 00:10 = ten minutes 00:15 = fifteen minutes 00:30 = thirty minutes (default setting) 00:45 = forty-five minutes 01:00 = one hour 01:30 = 90 minutes 02:00 = two hours 03:00 = three hours NEVER = forever—the unit will remain in loopback without use[...]
-
Page 15
27 28 4.3 POWER CONNECTION The Model 2094 offers three ways to supply external power: AC power , DC power and interface power . 4.3.1 Using the AC Power Supply (100-240V AC) The Model 2094 uses a 5VDC, 2A universal input 100-240V AC, power supply (center pin is +5V). The universal input power supply is equipped with a male IEC-320 power entry conne[...]
-
Page 16
29 30 LOS The Loss of Sync LED lights when the unit loses synchronization with the incoming sig- nal. This may happen when there is a fram- ing mismatch or a loss of signal. In unframed mode, the LOS LED monitors the status of the transmit clock. ALM The alarm LED indicates the presence of a AIS or RAI, or Out of Frame condition. The ALM LED will b[...]
-
Page 17
31 32 T o perform an RDL test, follow these steps: 1. Activate RDL. This may be done in two ways: a. Enter Remote Loop from the System Diagnostics/Statistics menu and toggle the <Spacebar> until “TM” appears next to the Remote Loop option.; b. Activate the “RL” signal on the DTE. If you are not sure which lead is the “RL” signal, [...]
-
Page 18
33 34 APPENDIX A P A TTON MODEL 2094 SPECIFICA TIONS Network Data Rate: 2.048 Mbps Network Connector: RJ-48C Nominal Impedance: 120 ohm (75 ohm available when using Patton Model 460 Balun) DTE Interface: V .35 (DCE Orientation) on Male M/34 Line Coding: Selectable AMI or HDB3 Line Framing: G.703 (Unframed) or G.704/G.732 (Framed) CAS Multiframing: [...]
-
Page 19
35 36 APPENDIX C P A TTON MODEL 2094 F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Model # Description 2094/CM/UI .....................V .35 to E1 Converter (V .35 M/34 Male, UI) 10 - 09F ...........................6 Foot Control Port Cable, 25 mm to DB9F 08055DCUI......................Universal Input Power Supply 10-CISCO-V35FT -1 .........C[...]
-
Page 20
37 38 APPENDIX D (continued) P A TTON MODEL 2094 INTERF ACE PIN ASSIGNMENTS M/34 Connector , T erminal Interface Pin # Signal A GND (Earth Ground/Shield) B SGND (Signal Ground) D CTS (DCE Source) E DSR (DCE Source, Always On) F CD (DCE Source) L LL (Local Loop, DTE Source) M TM (T est Mode Indicator (DCE Source) N RL (Remote Loop, DTE Source) P TD [...]