Go to page of
Similar user manuals
-
Switch
Patton electronic 593/45, 593/TB, RS-422, RS-485
8 pages 0.3 mb -
Switch
Patton electronic 2701/I
32 pages 0.48 mb -
Switch
Patton electronic 1068 VDSL
5 pages 0.23 mb -
Switch
Patton electronic 2156 & 2157
20 pages 0.56 mb -
Switch
Patton electronic 2130
24 pages 0.65 mb -
Switch
Patton electronic 9100
8 pages 0.31 mb -
Switch
Patton electronic 457B
5 pages 0.05 mb -
Switch
Patton electronic 2100
1 pages 0.06 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Patton electronic 2174, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Patton electronic 2174 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Patton electronic 2174. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Patton electronic 2174 should contain:
- informations concerning technical data of Patton electronic 2174
- name of the manufacturer and a year of construction of the Patton electronic 2174 item
- rules of operation, control and maintenance of the Patton electronic 2174 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Patton electronic 2174 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Patton electronic 2174, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Patton electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Patton electronic 2174.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Patton electronic 2174 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
USER MANU AL M ODEL 21 7 4 Copper LINK™ High Speed Ethernet Extender SALES OF FICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 Part# 07 M21 74-UM Rev . A Revised 9/ 23/1 1 An I SO-9001 Certi fied Company This is a Clas s A d evice and is not inte nded for use in a r esiden tial e nvironm ent.[...]
-
Page 2
2 CONTENTS 1.0 Warranty Info rmation ....... ................. ...................... ................... 4 1.1 Regulato ry Information ............ ....................... ................. ............. 4 EMC Directive:.............. ...... ................. ..... ...... ..... ...... ................. .. 4 Low-Voltage Direcive (Safety): .........[...]
-
Page 3
3 RJ-45 ....................... ...................... ...................... ................. ...... 19 C.2 CopperLINK Interfac e ............ ................. ....................... ............ 19 RJ-45 ....................... ...................... ...................... ................. ...... 19 Terminal Block .............. .............[...]
-
Page 4
4 1.0 W ARRANTY INFOR MATION Patton Electroni cs warrants all Model 2174 comp onents to be free fro m defect s, and wi ll—at our optio n—repair or replace th e product sh ould it fail w ithin one ye ar from the first d ate of the shi pment. This warran ty is limite d to defect s in workman ship or material s, and does not cov er customer dam ag[...]
-
Page 5
5 tion. The devi ce h as b een tested a nd fo und t o co mp ly wi th the lim its for a Class A com puting devi ce i n acc ordance with spec ificatio ns in Subp ar t B of Part 15 of FCC rule s, which ar e designed to p rovide rea sonable pro - tection from such i nterference in a commerci al insta llation. Howe ver , there is no gua rantee tha t in [...]
-
Page 6
6 1.6 SA FETY WHEN W ORKING W ITH ELEC TRICITY • This devic e contai ns no us er ser vice able par ts. Th is device can onl y be repaired by qu alified service per - sonn el. • Do not open the devi ce when the po wer cord is con - nect ed. For sys tems wi thout a po wer swi tch and wit hout an ext ernal power ad apter , line voltag es are prese[...]
-
Page 7
7 In accordance with the requirements of council direc - tive 2002/9 6/EC on Waste of Ele ctric al and El ectr onic Equip ment (WEE E), ens ure that at end -of-life you sep a - rate t his pro duct from other wa ste and scr ap and de liver to the WEEE collection system in y our country for recy - cli ng. This d evice con tains no user ser viceable p[...]
-
Page 8
8 2.0 GENERAL INFORMATION Thank y ou for your pu rchase of thi s Patton Elect ronics produ ct. This produ ct has been thoroughly i nspected and tested and i s warranted for one yea r for pa rts and la bor . If any question s or problems arise du ring inst allation or u se of this pro duct, cont act Patton Ele ctronics T ech nical Support at +1 (301[...]
-
Page 9
9 Figure 1. T ypical ap plicatio n The pair of 2174 model s work together to create a transp a rent extensio n between two peered Ethernet LANs using tw isted p air (2-wire), Cat5+, or 75-ohm BNC. Figure 1 shows a ty pical po int-to-point application. 3.0 INSTALLATION T o inst all the 2174 Ethernet Ext ender , do t he following: 1. Connect t he lin[...]
-
Page 10
10 Figure 2. Model 2174 rear panel optio ns Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A Eth3 Eth0 Eth1 Eth2 12VDC 1A[...]
-
Page 11
11 3.1 CO NNECTING THE LINE INTER FACE The Mod el 2174 supp orts com munication bet ween two pee r Ethernet LAN s ites o ver a dis tance of up t o 10 , 000 ft ( 3 km) over 2 4 AWG (0.5 mm) twis ted-pair wire, Ca t5+, or 75-ohm BNC. Not e Actual distance and link performance may vary depending on the environment and type/gauge of wire used. Follow t[...]
-
Page 12
12 Figure 4. Model 2174 (T erminal Block) twisted pair line interface Connec ting the Line I nterface for Model 2174/BN C T o connec t the line in terface of the Model 2174/B NC, simp ly use a co ax - ial cab le with a BNC c onnector at e ach end to c onnect the pa ir of Model 2174 s. 3.2 CO NNECTING THE 1 0/1 0 0BASE- T ETHE RNET I NTER FACE The R[...]
-
Page 13
13 3.3 CO NNECTING PO WER The Mod el 2174 does not have a power swit ch, so it pow ers up as s oon as it is plugged in . An external AC or DC power sup ply is avail ab le se paratel y . This conne c - tion is made via th e barrel ja ck on the rea r panel of the Model 2174. No configu ration is nec essary for t he power su pply (See Appen dix B for [...]
-
Page 14
14 Figure 6. DIP s witch or ient ation 4.2 CONFIGUR IN G DIP SWITCH S1 DIP swit ch S1 is w here you configure the Copp erLINK lin e. The foll owing ta bles descr ibe the confi guration fo r the 2174. T able 1: S1 S um mar y Position Descriptio n S1-1 Local /Remote Con figuration S1-2 Line Ra te/Symmetry S1-3 Line Ra te/Symmetry S1-4 Reserved S1-5 S[...]
-
Page 15
15 Switch S1-1 : Local/Remote C onfiguration Use sw itch S1-1 to conf igure the unit as Remote or L ocal in the M odel 2174 pai r . Switches S1-2 and S1-3: Symmetric/Asy mmetric Operation Use sw itches S1-2 and S1-3 to configu re the Coppe rLink line ra te type - and ope ration. Not e See Appendix D on page 20 for l ine rate distances. Switch S1-5:[...]
-
Page 16
16 5.0 OPERATION Once t he Model 217 4s are properl y installed , they shoul d operate t rans - paren tly . No user se ttings require d. This sec tion describ es reading th e LED st atus moni tors. Before app lying power to the Model 2 174, please review sectio n 3.3, “Connecti ng Pow er” on p age 13 to verify th at the un it is co nnecte d to [...]
-
Page 17
17 APPE NDIX A S PECIFICATIONS A.1 L AN CO NNECTION • Four RJ-45 , 10/100Base-T , IEE E 802.3 Ethernet • Coppe rLINK Connecti on: RJ-45 A.2 T RANS MISSI ON LI NE T wo-wire uncondi tioned twisted pair or 75- ohm BNC A.3 C OPPERLI NK LI NE RATE AND COPPERL INK DIST ANCE • Line Rate: Up to 2 00 Mbps asy mmetrical • Dist ance: Up to 9 ,842 ft ([...]
-
Page 18
18 APPE NDIX B MODEL 2174 SERIES FACTO RY REPLACEMENT PARTS AND ACCESSORIES Patton Model # Description Base Mode ls 2174/EUI-2PK High S peed CopperLink Ethernet Extender K it (Local and Remote); RJ45 Line, 100-240V AC 2174/TB/EUI-2PK High Speed CopperLink Ethernet Extender K it (Local and Remote); T er minal Block Line, 100-240V AC 2174/BNC/EUI-2PK[...]
-
Page 19
19 APPE NDIX C MODEL 2174 SERIES INTERFACE PIN ASSIGNMENT C .1 1 0/1 00BASE -T INT ER FAC E RJ-45 • Pin 1: TX + • Pin 2: TX - • Pin 3: RX + • Pin 6: RX - • Pins 4, 5 , 7, 8: no c onnection C .2 CO PPERLINK INTE R F ACE RJ-45 • Pin 4: RI NG • Pin 5: TI P • Pins 1, 2, 3, 6, 7, 8 : no connect ion T erminal Block Figure 1. Model 2174 (T[...]
-
Page 20
20 APPE NDIX D LINE RATE & REACH CHART, BASED ON 24 AWG (0.5 MM) Not e The actual distance and link performance may vary depending on the environment and type/gauge of wire used. Not e DS = downstream, US = upstream Not e This chart applies to Model 2174s wi th a twisted-pair li ne inter- face: Model 2174/EUI and 2174/ TB . Contact Patton for M[...]
-
Page 21
21 Not e The actual distance and link performance may vary depending on the environment and type/gauge of wire used. Not e DS = downstream, US = upstream Not e This chart applies to Model 2174s wi th a twisted-pair li ne inter- face: Model 2174/EUI and 2174/ TB . Contact Patton for Model 2174/BNC rates. Ta b l e 7 : Line Rate & Reach Chart U si[...]
-
Page 22
22 NOTES _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ________[...]
-
Page 23
23 NOTES _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ___________ _________ ___________ __________ _______ _________ ________[...]
-
Page 24
24 Cop yri gh t © 20 1 1. Patton Ele ctronics Comp any All Righ ts Reserved.[...]