Patton electronic 3060/V24 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Patton electronic 3060/V24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Patton electronic 3060/V24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Patton electronic 3060/V24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Patton electronic 3060/V24 should contain:
- informations concerning technical data of Patton electronic 3060/V24
- name of the manufacturer and a year of construction of the Patton electronic 3060/V24 item
- rules of operation, control and maintenance of the Patton electronic 3060/V24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Patton electronic 3060/V24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Patton electronic 3060/V24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Patton electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Patton electronic 3060/V24.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Patton electronic 3060/V24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Doc #: 102001UA Part #: 07M3060/V24-A D IGIT AL B RIDGE 3060/V24 (CTS MD-V.24/TCB) I NST ALLA TION AND O PERA TIONS M ANUAL B Copyright © 2000 Patton Electronics Co., All Rights Reserved. An ISO-9001 Certified Company January 4, 2000[...]

  • Page 2

    3060/V24 102001UA i P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL COPYRIGHT NOTICE Copyright © 2000 Patton Electronics Co., All Rights Reserved. PROPRIET A RY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or in pa[...]

  • Page 3

    3060/V24 102001UA ii I NSTALLATION A ND O PERATIONS M ANUAL P ATTON E LECTRONICS C O . EMISSION REQUIREMENTS FCC CLASS A Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply wi[...]

  • Page 4

    3060/V24 102001UA iii P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL Contents CHAPTER 1 - OPERA TION Channel Clocking ............................................................................................................... ................ 1-1 Fallback Clocking ...............................................................[...]

  • Page 5

    3060/V24 102001UA 1-1 O PERATION P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL CHAPTER 1 - OPERA TION The Patton 3060/V24 (MD-V.24/TCB) is a network enhancement accessory intended for high speed synchronous or asynchronous RS-232 modem, or port sharing applications. The 3060/ V24 (MD-V.24/TCB) allows for immediate expansion of a [...]

  • Page 6

    3060/V24 102001UA 1-2 I NSTALLATION A ND O PERATIONS M ANUAL O PERATION P ATTON E LECTRONICS C O . Anti-streaming A typical problem often encountered is a “ STREAMING ” remote terminal. The streaming problem can tie up an entire circuit until the offending device has recovered or is powered down. A streaming condition occurs when a Sub-Channel [...]

  • Page 7

    3060/V24 102001UA 1-3 O PERATION P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL Channel Selection Modes The Patton 3060/V24 (MD-V.24/TCB) provides two selectable Sub-Channel service modes of operation, the Scanning Mode and Priority Mode. Depending on system requirements, either mode may be selected by internal DIP switch settings[...]

  • Page 8

    3060/V24 102001UA 1-4 I NSTALLATION A ND O PERATIONS M ANUAL O PERATION P ATTON E LECTRONICS C O . Channel Tail Circuits A buffer is built into the unit for tail circuit (DCE to DCE) applications. An 8 bit centered ring buffer is used to correct the clock phasing errors generated between the Modem on the Master Port and the Sub-Channel port for the[...]

  • Page 9

    3060/V24 102001UA 2-1 S ETUP & I NSTALLATION P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL Caution, Disconnec t the POWER Be f or e Removing The Cover V orsicht, Be for Deckung Abnehmen Mach S tr om Zu. CHAPTER 2 - SETUP AND INST ALLA TION Power Connection Before connecting the 3060/V24 (CTS MD-V.24/TCB) to a AC power source [...]

  • Page 10

    3060/V24 102001UA 2-2 I NSTALLATION A ND O PERATIONS M ANUAL S ETUP & I NSTALLATION P ATTON E LECTRONICS C O . Switch 24 - All to ON ON ON ON ON RX Clock Source = Master Contention Mode = Priority Switch 25 - All to ON ON ON ON ON Sub-Channel Activity Indicated by Interface Control (RTS/DCD) If the system application requires one or more of the[...]

  • Page 11

    3060/V24 102001UA 2-3 S ETUP & I NSTALLATION P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL RTS To CTS Delay (SW22-1,2,3) If a CTS delay is desired, set SW22-1, 2 and 3 to the required value as indicated below. SW22-1 SW22-2 SW22-3 Time ON ON ON No Delay OFF ON ON 1mS ON OFF ON 2mS OFF OFF ON 4mS ON ON OFF 9mS OFF ON OFF 18mS [...]

  • Page 12

    3060/V24 102001UA 2-4 I NSTALLATION A ND O PERATIONS M ANUAL S ETUP & I NSTALLATION P ATTON E LECTRONICS C O . Control Turn-Off Delay in "DATA" Switching Mode (SW23-1,2) When configured to switch on DATA, switch SW23-1 and 2 set the Sub-Channel release time in clocks. The value selected is the number of clocks at the current baud rate[...]

  • Page 13

    3060/V24 102001UA 2-5 S ETUP & I NSTALLATION P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL Fallback Clock Enable (SW-23-5) If Clock Fallback is required when the primary clock fails, set switch SW23-5 to OFF OFF OFF OFF OFF . If Fallback is not required set SW23-5 to ON ON ON ON ON . The Fallback clock rate is selected with t[...]

  • Page 14

    3060/V24 102001UA 2-6 I NSTALLATION A ND O PERATIONS M ANUAL S ETUP & I NSTALLATION P ATTON E LECTRONICS C O . RX Clock Source Selection (SW24-1,2,3) RX Clock Source is selected by SW24-1, 2 and 3. The following table indicates the source options provided by the 3060/V24 (CTS MD-V.24/TCB). If the TXC source is pin 24, both RXC and TXC will be s[...]

  • Page 15

    3060/V24 102001UA 2-7 S ETUP & I NSTALLATION P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL configured as a DTE, pins 9 and 10 are open. JP4 and JP5 control Plus Unreg and Minus Unreg to all Sub-Channels, therefore it is not possible to have test power on one DCE without having it on all DCE Sub-Channels. Test Voltage Enable P[...]

  • Page 16

    3060/V24 102001UA 2-8 I NSTALLATION A ND O PERATIONS M ANUAL S ETUP & I NSTALLATION P ATTON E LECTRONICS C O . FACTORY Test Jumpers (JP1, JP2 and JP3) The three test jumpers JP1, 2 and 3, must be installed for the unit to properly function. These jumpers are used in the manufacture and test of the product prior to shipment.[...]

  • Page 17

    3060/V24 102001UA A-1 A PPENDIX P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL APPENDIX Interface Pins Supported Typical Tail Circuit Configuration Typical Application DB- 25 RS- 232 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Shield (common) Transmit Data (f rom DTE) Receive Data (from D CE) Request to Send [...]

  • Page 18

    3060/V24 102001UA A-2 A PPENDIX P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL Master DTE / Sub-Channel DCE Interface Flow Diagram Master DTE / Sub-Channel DTE Interface Flow Diagram Master Port is a DTE Pin 3 RXD Pin 2 TXD Pin 2 TX D Pin 3 RXD Pin 4 R TS Pin 5 CTS Pin 6 DSR Pin 8 DC D Pin 20 DTR Pin 4 R TS Pin 5 C TS Pin 6 D SR P[...]

  • Page 19

    3060/V24 102001UA A-3 A PPENDIX P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL Master DCE / Sub-Channel DTE Interface Flow Diagram Master DCE / Sub-Channel DCE Interface Flow Diagram Pin 15 TXC Pin 17 R XC Pin 24 ET XC Pin 15 TXC Pin 17 R XC Pin 24 ETXC Master RX Clock Selection L ogic Master T X Clock Selectio n Logic Pin 20 DTR [...]

  • Page 20

    3060/V24 102001UA A-4 A PPENDIX P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL TECHNICAL SPECIFICA TIONS Applications Multiple RS-232 Sync or Async DCE or DTE devices sharing one RS-232 DCE or DTE link Capacity One to Six RS-232 Sync or Async DTE or DCE devices One RS-232 DCE or DTE Master Channel Data Format Data transparent at a[...]

  • Page 21

    3060/V24 102001UA A-5 A PPENDIX P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL Port Enabled = GREEN SW 7 SW 10 SW 9 SW 14 SW 13 SW 16 SW 15 SW 17 SW18 SW 20 SW 12 SW 19 SW 11 SW 8 Master Port 1 Port 2 Port 3 Port 4 Master Port 3 Port 4 Port 5 Port 6 Port 2 Port 3 Port 4 Port 5 Port 6 PWR TXD RXD Sub-Channel Active Anti-Stream Not [...]

  • Page 22

    B 7622 Rickenbacker Drive Gaithersburg, MD 20879 Sales: 301 975-1000 Suppor t: 301 975-1007 W eb Addr ess: www .patton.com[...]