Go to page of
Similar user manuals
-
TV Converter Box
Patton electronic 285S
9 pages 0.07 mb -
TV Converter Box
Patton electronic RS-485
9 pages 0.07 mb -
TV Converter Box
Patton electronic 222NS
20 pages 1.57 mb -
TV Converter Box
Patton electronic IC-V.24
10 pages 0.22 mb -
TV Converter Box
Patton electronic 2026
16 pages 0.42 mb -
TV Converter Box
Patton electronic X.21
10 pages 0.22 mb -
TV Converter Box
Patton electronic 2027
16 pages 0.42 mb -
TV Converter Box
Patton electronic 2011
7 pages 0.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Patton electronic X.21, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Patton electronic X.21 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Patton electronic X.21. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Patton electronic X.21 should contain:
- informations concerning technical data of Patton electronic X.21
- name of the manufacturer and a year of construction of the Patton electronic X.21 item
- rules of operation, control and maintenance of the Patton electronic X.21 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Patton electronic X.21 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Patton electronic X.21, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Patton electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Patton electronic X.21.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Patton electronic X.21 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
I NTERFACE C ONVERTER , V .24 TO X.21 2021P (CTS IC-V .24/X.21) I NST ALLA TION AND O PERA TIONS M ANUAL Doc#: 172001UA Part#: 07M2021P-A B February 21, 2000 An ISO-9001 Certified Company Copyright© 2000 Patton Electronics Co., All Rights Reserved[...]
-
Page 2
172001UA i T able of Contents CHAPTER 1 - Operation CHAPTER 2 - SETUP AND INST ALLA TION Installation .................................................................................... 2-1 Selection of DTE/DCE ................................................................. 2-1 Equipment Grounding ................................................[...]
-
Page 3
172001UA ii PROPRIETARY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given by Patton Electronics Co. SERVICE All warranty and non-warranty repairs must be returned [...]
-
Page 4
172001UA CHAPTER 1 - Operation The Patton 2021P (CTS TCB-V.24/X.21) is an EIA RS-232 to CCITT X.21 interface converter with a built in tail circuit buffer, allowing modem to modem interconnection. The interface converter operates bi-directionally. DCE / DTE selection of each port permits interfacing an RS-232 terminal or modem to an X.21 terminal o[...]
-
Page 5
172001UA CHAPTER 2 - SETUP AND INST ALLA TION Installation Set the switches to match the required configurations based on the diagrams below. The cabling between each device and the interface converter must be terminated with male connectors. J1 is the RS-232 / V.24 interface and J2 is the X.21 interface. The IEC connector is provided to interface [...]
-
Page 6
172001UA 2-2 slaved to this clock. To connect a X.21 terminal type device (DTE) to an RS-232 Modem type device (DCE), connect the terminal to J2 and the Modem to J1. Move SW1 and SW2 to the DTE position, and SW3, SW4 and SW5 to the DCE position, as shown in Fig.2. X.2 1 D TE X.2 1 DCE V.24 DTE TX D - 2 TX C - 1 5 RX C - 1 7 S - 6, 1 3 T - 2, 9 V. 2[...]
-
Page 7
172001UA 2-3 I Po wer T S R J3 C Fa cto ry Tes t Stra ps Mu st be Ins tall ed f o r U nit To O per at e C or re ct ly J1 (RS- 23 2) Is a DTE, an d MU ST Co nn ec t t o a Mo de m (D CE) J 2 ( X.2 1) Is a D TE, a nd MU ST C o n ne ct t o a M o dem ( DC E) J2 X. 2 1 J1 RS- 23 2 JP 3 JP 2 JP 1 JP4 SW1 X.2 1 I NTER FA CE DC E D TE Sig n al to Ch a ssi s[...]
-
Page 8
172001UA A-1 APPENDIX TECHNICAL SPECIFICA TIONS Applications RS-232 to CCITT X.21 interface conversion Capacity One RS-232 Channel One CCITT X.21 Channel Buffer Bidirectional 8-bit ring buffer Data Format Transparent to Data Data Rates Up to 128Kbps Electrical Interface RS-232 and V.11 RS-232 Physical Interface Female DB-25 (V.24) Connector Balance[...]
-
Page 9
172001UA A-2 Shield (co mmon) Tr a ns m it (A) (f ro m DT E ) Con tro l( A) ( fro m DTE ) Rece ive(A) (from DCE) Ind ic ati o n(A ) (fr om DCE) Si g na l T i min g(A ) (f r o m DC E) GND (c omm on ) Tr a ns m it (B) (f ro m DT E ) Con tro l( B) ( fro m DTE ) Rece ive(B) (from DCE) Ind ic ati o n(B ) (fr om DCE) Si g na l T i min g(B ) (f r o m DC E[...]
-
Page 10
B Sales: 301 975-1000 Suppor t: 301 975-1007 W eb Address: http://www .patton.com 7622 Rickenbacker Drive Gaithersburg, MD 20879[...]