Go to page of
Similar user manuals
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Peavey 1564, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Peavey 1564 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Peavey 1564. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Peavey 1564 should contain:
- informations concerning technical data of Peavey 1564
- name of the manufacturer and a year of construction of the Peavey 1564 item
- rules of operation, control and maintenance of the Peavey 1564 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Peavey 1564 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Peavey 1564, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Peavey service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Peavey 1564.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Peavey 1564 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Frequency Response, 1 meter on-axis, swept-sine in anechoic environment: 47 Hz - 18.5 kHz (±3 dB) Usable Low Frequency Limit (-10 dB point): 38 Hz Power Handling: Full Range: 750 w continuous 1,500 w program 3,000 w peak Low Frequency Section: 600 w continuous 1,200 w program 2,400 w peak High Frequency Section: 100 w continuous 200 w program 400 [...]
-
Page 2
3rd Harmonic: 100 Hz: 0.27% 1 kHz: 0.51% 10% rated power 2nd Harmonic: 100 Hz: 6.58% 1 kHz: 0.87% 3rd Harmonic: 100 Hz: 1.14% 1 kHz: 0.78% Crossover Frequency (internal passive): Low Frequency - High Frequency: 1,600 Hz Time Offset: Low Frequency: 0.00 ms High Frequency: 0.74 ms I mpedance (Z): Full Range: Nominal: 8.0 Ω Minimum: 7.6 Ω Low Freq[...]
-
Page 3
3 Features • 47 Hz to 18.5 kHz bandpass • 4" diaphragm, 1.6" exit, ferrofluid equipped high frequency compression driver • Patented Quadratic Throat Waveguide • Carefully tailored directivity patterns • Flexible suspension provisions • Robust power handling capabilities • Passive crossover included • Biamplified crossover [...]
-
Page 4
4 may be biamplified. T welve 3/8 inch x 16 threaded mounting suspension points (three each top and bottom and two each sides and back) allow a variety of suspension configurations. Multiple units may be mounted to form a vertical/horizontal array [see limitations under mounting instructions]. Both versions of the ILS 1564 are solidly constructed o[...]
-
Page 5
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 200 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 315 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 500 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 800 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.25 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.6 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 2.5[...]
-
Page 6
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 3.15 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 8 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 12.5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 16 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 4 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 6.3 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 10 [...]
-
Page 7
0 o 30 o 60 o 90 o -30 o -60 o -90 o 200 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 315 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 500 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 800 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.25 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.6 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 2.5[...]
-
Page 8
0 o 30 o 60 o 90 o -30 o -60 o -90 o 3.15 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 8 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 12.5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 16 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 4 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 6.3 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 10 [...]
-
Page 9
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 200 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 315 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 500 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 800 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.25 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.6 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 2.5[...]
-
Page 10
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 3.15 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 8 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 12.5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 16 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 4 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 6.3 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 10 [...]
-
Page 11
0 o 30 o 60 o 90 o -30 o -60 o -90 o 200 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 315 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 500 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 800 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.25 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.6 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 2.5[...]
-
Page 12
0 o 30 o 60 o 90 o -30 o -60 o -90 o 3.15 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 8 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 12.5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 16 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 4 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 6.3 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 10 [...]
-
Page 13
8.585 33.750 21.710 A A 8.702 2.250 10.896 19.361 View A-A 2.250 29.250 8.283 11.125 2.250 ILS 1564 H 13[...]
-
Page 14
8.585 19.361 21.710 A A 8.702 2.250 10.896 33.750 2.250 11.125 View A-A 2.250 29.250 8.283 ILS 1564 V 14[...]
-
Page 15
15 ILS ™ 1564 INPUT[...]
-
Page 16
Features and specifications subject to change without notice. Peavey Electronics Corporation • 71 1 A Street • Meridian • MS • 39301 (601) 483-5376 • F AX (601) 486-1678 • http://aa.peavey .com ©2000 Printed in the U.S.A. 9/00 80304692[...]