Go to page of
Similar user manuals
-
Speaker
Peavey HDH-2
4 pages 0.32 mb -
Speaker
Peavey A/A Series
4 pages 0.2 mb -
Speaker
Peavey SSE 15
12 pages 1.83 mb -
Speaker
Peavey 112
11 pages 1.82 mb -
Speaker
Peavey 115TVX
2 pages 0.94 mb -
Speaker
Peavey SSE 26
12 pages 0.91 mb -
Speaker
Peavey HDH 244T
4 pages 0.18 mb -
Speaker
Peavey 7G
8 pages 0.16 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Peavey ILS 1294 H, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Peavey ILS 1294 H one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Peavey ILS 1294 H. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Peavey ILS 1294 H should contain:
- informations concerning technical data of Peavey ILS 1294 H
- name of the manufacturer and a year of construction of the Peavey ILS 1294 H item
- rules of operation, control and maintenance of the Peavey ILS 1294 H item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Peavey ILS 1294 H alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Peavey ILS 1294 H, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Peavey service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Peavey ILS 1294 H.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Peavey ILS 1294 H item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Frequency Response, 1 meter on-axis, swept-sine in anechoic environment: 63 Hz - 18.5 kHz (±3 dB) Usable Low Frequency Limit (-10 dB point): 48 Hz Power Handling: Full Range: 750 W continuous 1,500 W program 3,000 W program Low Frequency Section: 500 W continuous 1,000 W program 2,000 W peak High Frequency Section: 100 W continuous 200 W program 4[...]
-
Page 2
3rd Harmonic: 100 Hz: 0.25% 1 kHz: 0.29% 10% rated power 2nd Harmonic: 100 Hz: 8.62% 1 kHz: 1.75% 3rd Harmonic: 100 Hz: 2.62% 1 kHz: 0.24% Crossover Frequency (internal passive): Low Frequency - High Frequency: 1,600 Hz Time Offset: Low Frequency: 0.00 ms High Frequency: 0.38 ms Impedance (Z): Full Range: Nominal: 8.0 Ω Minimum: 7.1 Ω Low Frequ[...]
-
Page 3
3 • Flexible suspension provisions • Robust power handling capabilities • Passive crossover included • Biamplified crossover provisions Applications • Stadiums • Arenas • Multi-purpose facilities • Cruise ships • Theme parks • Houses of worship • Live music venues • Hotel meeting rooms • Conference facilities • Theaters [...]
-
Page 4
Frequency Response This measurement is useful in determining how accurately a given unit reproduces an input signal. The frequency response of the ILS 1294H is measured at a distance of 1-meter using a 1 W att (into the nominal impedance) swept-sine input signal. As shown in figure 1, the selected drivers in the ILS ™ 1294H combine to give a smoo[...]
-
Page 5
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 200 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 315 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 500 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 800 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.25 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.6 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 2.5[...]
-
Page 6
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 3.15 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 8 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 12.5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 16 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 4 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 6.3 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 10 [...]
-
Page 7
0 o 30 o 60 o 90 o -30 o -60 o -90 o 200 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 315 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 500 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 800 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.25 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.6 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 2.5[...]
-
Page 8
0 o 30 o 60 o 90 o -30 o -60 o -90 o 3.15 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 8 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 12.5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 16 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 4 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 6.3 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 10 [...]
-
Page 9
9 ILS 1294H[...]
-
Page 10
10 ILS 1 294H A PRODUCT OF PEAVEY ELECTRONICS CORP. TM W ARNING: CONSUL T SPEC SHEET FOR FULL SUSPENSION RA TINGS. DO NOT EXCEED 400 lbs. OR 45 DEGREE ANGLE 6,059,069 AND 6,064,745 FULL R ANGE BIAMP 750W RMS CONT. 8 OHMS LF: 500W RMS CONT. 8 OHMS HF:100W RMS CONT. >1.0 kHz 8 OHMS ALL CONNECTORS ARE WIRED IN P ARALLEL INTERNALL Y . CHANGE INTERNA[...]
-
Page 11
11 NOTES:[...]
-
Page 12
Features and specifications subject to change without notice. Peavey Electronics Corporation • 71 1 A Street • Meridian • MS • 39301 (601) 483-5376 • F AX (601) 486-1678 • http://aa.peavey .com ©2001 Printed in the U.S.A. 06/01 80305022[...]