Peavey SSE 12 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Peavey SSE 12, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Peavey SSE 12 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Peavey SSE 12. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Peavey SSE 12 should contain:
- informations concerning technical data of Peavey SSE 12
- name of the manufacturer and a year of construction of the Peavey SSE 12 item
- rules of operation, control and maintenance of the Peavey SSE 12 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Peavey SSE 12 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Peavey SSE 12, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Peavey service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Peavey SSE 12.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Peavey SSE 12 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SPECIFIC A TION S SSE ™ 12 Description The S SE is a new enclosure series featuring high power ratings with custom components, a sleek look and a unique, snap-in metal grille. The S SE 12 is a two- way system featuring the highly acclaimed Peavey 14XT titanium compression driver with the diverse Sound Guard IV tweeter protection network and Peave[...]

  • Page 2

    2 Radiation angle measured at -6 dB point of polar response: 500 Hz to 1.6 kHz: Horiz. 110˚ ± 15˚ V ert. 120˚ ± 30˚ 1.6 kHz to 5 kHz: Horiz. 75˚ ± 15˚ V ert. 70˚ ± 25˚ 5 kHz to 16 kHz: Horiz. 85˚ ± 15˚ V ert. 40˚ ± 10˚ Directivity factor , Q (Mean): 10.27 ± 6.07 Directivity index, Di (Mean): 9.38 dB ± 2.57 dB T ransducer complem[...]

  • Page 3

    S S P P E E C C I I F F I I C C A A T T I I O O N N S S S S S S E E ™ ™ 1 1 2 2 20 50 100 200 500 1k 2k 5k 10k 20k Frequency (Hz) 60 70 80 90 100 11 0 dB SPL (re 20 Pa) Amplitude Response (1W 1m On-Axis) Figure 1 20 50 100 200 500 1k 2k 5k 10k 20k Frequency (Hz) 1 10 100 Q & Directivity Index Q Figure 4 20 10 Di 0 20 50 100 200 500 1k 2k 5k[...]

  • Page 4

    4 20 50 100 200 500 1k 2k 5k 10k 20k Frequency (Hz) 40 50 60 70 80 90 100 11 0 dB SPL (re 20 Pa) Harmonic Distortion : 1% Rated Power Figure 6 3rd Harmonic 2nd Harmonic 20 50 100 200 500 1k 2k 5k 10k 20k Frequency (Hz) 50 60 70 80 90 100 11 0 120 dB SPL (re 20 Pa) Harmonic Distortion : 10% Rated Power Figure 5 3rd Harmonic 2nd Harmonic[...]

  • Page 5

    0 o 30 o 60 o 90 o -30 o -60 o -90 o 50 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 0 o 30 o 60 o 90 o -30 o -60 o -90 o 125 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 200 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 315 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 250 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 400 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 630 Hz 0 o 30[...]

  • Page 6

    6 0 o 30 o 60 o 90 o -30 o -60 o -90 o 800 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.25 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 2 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 3.15 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 4 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 6.3 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1[...]

  • Page 7

    0 o 30 o 60 o 90 o -30 o -60 o -90 o 12.5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 16 kHz V ertical Polar Patterns 6 dB per Division SPECIFIC A TION S SSE ™ 12 7[...]

  • Page 8

    8 -90 o -60 o -30 o 0 o 30 o 60 o 90 o 50 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 80 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 125 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 200 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 315 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 250 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 400 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 630 H[...]

  • Page 9

    9 -90 o -60 o -30 o 0 o 30 o 60 o 90 o 800 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.25 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 2 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 3.15 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 4 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 6.3 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1[...]

  • Page 10

    10 -90 o -60 o -30 o 0 o 30 o 60 o 90 o 12.5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 16 kHz Horizontal Polar Patterns 6 dB per Division[...]

  • Page 11

    11 Input Plate SPECIFIC A TION S SSE ™ 12[...]

  • Page 12

    www .sanctuary-series.com 80305311 Features and specifications subject to change without notice. Peavey Electronics Corporation 711 A Street Meridian, MS 39301 (601) 483-5365 F AX (601) 486-1278 ©2004 P rinted in the U.S.A. 3/04[...]