A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco 27X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco 27X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco 27X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco 27X should contain:
- informations concerning technical data of Pelco 27X
- name of the manufacturer and a year of construction of the Pelco 27X item
- rules of operation, control and maintenance of the Pelco 27X item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco 27X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco 27X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco 27X.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco 27X item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    QUICK START C3462M (9/09) 23X, 27X, and 35X Models Spectra ® IV SL and Spectra IV SE Series Dome Systems[...]

  • Page 2

    2 C3462M (9/09) Installing the Dome Drive 1. Perform one of the following options: • View video using bot h analog and IP connections: Set the DIP sw itches on the to p of the Spectra IV dome drive (refer to Figure 12). Fo r DIP switch se ttings, refe r to the labe ls located on t he top of the dome drive, o r refer to Switch Settings on pa ge 3.[...]

  • Page 3

    C3462M (9/09) 3 SWITCH SETTINGS WAR N I NG : If you are using Pelco D-type or P-type contro l, your system may not operat e if the baud rate and address swi tches are n ot set corr ectly . The switches ar e set at th e factory at t he default s for Pelco D-type co ntrol (2400 baud and address 1). T able A. Switch Settings for SW2 Special Systems S [...]

  • Page 4

    4 C3462M (9/09) T able B. Switch Settings for SW1, P-T ype Control NOTE: For Coaxitro n controls, SW1 is not us ed; set all switches to OFF . For D-type control systems, refer to T a ble C. T able C. Switch Settings for SW1, D-T ype Control NOTE: For Coaxitro n controls, SW1 is not us ed; set all switches to OFF . For P-type control systems, refer [...]

  • Page 5

    C3462M (9/09) 5 SPECTRA ADDRESS SWITCH SET TING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 71 ON ON ON OFF O FF OFF ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OFF ON OFF ON OFF OFF ON OFF 75 ON ON OFF ON OFF OFF ON OFF 76 OFF OFF ON ON OFF OFF ON OFF 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OF F OFF ON OFF[...]

  • Page 6

    6 C3462M (9/09) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW 1-6 SW1-7 SW1-8 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ON [...]

  • Page 7

    C3462M (9/09) 7 SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231[...]

  • Page 8

    8 C3462M (9/09) Preset 95: Accessing the Main Menu Y ou ca n call up the main menu on y our monitor by programming (setting or creating) preset 95 (preset 28 in AD32-preset mode). Programming preset 9 5 for Pelco’ s controllers varies according to the type of controller you are using. Instruct ions for programming pre set 95 are given below for v[...]

  • Page 9

    C3462M (9/09) 9 MPT9500 Extended Coaxitron or RS-485 Mo de 1. Enter 95 and press t he PRESET SET key . 2. Press the F2 key . The main menu appears. NET300/NET350/NET4001A 1. Check the Set box. 2. Click the preset 95 button. Th e main menu appears. ENDURA W ORKSTATION 1. Right-click in the video pane of the Spectra IV dome system. 2. Click Preset an[...]

  • Page 10

    10 C3462M (9/09) T roubleshooting T o use your dome, refer to the instal lation an d operation /configurat ion manual s on the resou rce disc. If the following instr uctions fail to solve your problem, con tact Pelco Prod uct Support at 1-800-289-9 100 (USA and C anada) or +1-559-2 92-1981 (in ternationa l) for ass istance. Be su re to have th e se[...]

  • Page 11

    PRODUCT W ARRANTY AND RETURN INFORM A TION WARRANTY Pelco will repair o r replace, without c harge, any merchand ise proved defectiv e in material or workmanshi p for a period of one year after the date of shipment. Exceptions to this warranty are a s noted below: • Five year s: – Fiber optic prod ucts – TW3000 Series unshield ed twisted pair[...]

  • Page 12

    Pelco, Inc. W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el (800) 289-9100 Fax (800) 289-9150 International T el +1 (559) 29 2-1981 Fax +1 (559) 348-1120 www .pelco.c om[...]