Pelco BB5HD manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco BB5HD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco BB5HD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco BB5HD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco BB5HD should contain:
- informations concerning technical data of Pelco BB5HD
- name of the manufacturer and a year of construction of the Pelco BB5HD item
- rules of operation, control and maintenance of the Pelco BB5HD item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco BB5HD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco BB5HD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco BB5HD.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco BB5HD item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    00546 BB5HD Series Heavy-Duty Spectra ® Back Box Installation Manual C2429M (3/01) P elco • 3500 P elco Wa y • Clovis , CA 93612-5699 USA • www .pelco .com In Nor th America and Canada: T el (800) 289-9100 • F AX (800) 289-9150 International Customers: T el +1(559) 292-1981 • F AX +1(559) 348-1120[...]

  • Page 2

    CONTENTS IMPORT ANT SAFEGUARDS AND W ARNINGS ......................................................................................................... 3 DESCRIPTION ................................................................................................................................................................... 4 MODELS ............[...]

  • Page 3

    IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically mar ked as a NEMA T ype 3, 3R, 3S, 4, 4X, 6, or 6P enclosure , it is design[...]

  • Page 4

    DESCRIPTION The Heavy-duty Spectra is perf ect for installations where structural integ r ity and v andalism are a pr iority . The system f eatures barrel ke y locks , heavy-duty construction and a thick acr ylic low er dome. The in-ceiling model has a reinf orced bracket mounting system f or installation in a fixed ceiling. Pendant models can be m[...]

  • Page 5

    S INST ALLA TION IN-CEILING MODEL STEP 1 - PREP ARE CEILING 00530 a. Locate the center point of the mount- ing location. Drill a hole in the ceiling using a 3/32-inch drill. 00531 b. Insert the compass tool into the hole. Draw a circle on the ceiling using the compass tool and a pencil. Cut the circle out of the ceiling. STEP 2 - INST ALL THE MOUNT[...]

  • Page 6

    STEP 4 - WIRE CIRCUIT BOARD Attach the wiring to the circuit board inside the back box. When finished, close the door to the back bo x and turn on the power . The red LED will light. IMPORT ANT : If the LED does not light, ref er to the T rouble- shooting section . NOTE: Aux 1 - Maximum 2A at low voltage (<40V) Aux 2 - Maximum 150 vA at 32 VDC S[...]

  • Page 7

    INST ALLA TION PENDANT MODELS STEP 1 - MOUNT AND INST ALL THE BACK BOX NOTE: If installing outdoors make sure the installation is properly sealed to keep moisture out. 00540 00535 a. Install the mount for the pendant dome. Refer to the instruc- b. T ur n the thumbscrew and open the hinged door located inside tions supplied with the mount. Bring the[...]

  • Page 8

    STEP 3 - INST ALL DOME DRIVE LABEL SW1 L A B E L S W 2 SW1 SW2 RS-422 TERMINA TION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 GREEN T AB RED T AB 00538 a. Set the DIP switches for SW1 and SW2 on the bottom of the dome drive for the appropriate receiver address. Refer to the labels on the dome drive or tables C through E in the Appendix in the[...]

  • Page 9

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Unit does not operate. The controller is not communicating with the Spectra unit. Check to see if the red LED on the circuit board in the back box is lit. 1. The red LED is not lit . a. Fuse is bad. b. 24 V AC pow er source is not con- nected or back box is bad. 2. The red LED is lit . a. Wiring is in[...]

  • Page 10

    APPENDIX Ta b le A. Video Coaxial Cable Wiring Distances Cable T ype* Maximum Distance RG59/U RG6/U RG11/U 750 ft (229 m) 1,000 ft (305 m) 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor. 95% braided copper shield. Ta b le B. 24 V A C Wir ing Distances The follo wing are the recommended maximum distance[...]

  • Page 11

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Ta b le D. Switch Settings f or SW2 – P-T ype Control NO TE: F or Coaxitron controls , SW2 is not used; set all switches OFF . For D-type control systems, ref er to T able E. Receiver Address SW2-1 SW2-2 Switch Setting SW2-3 SW2-4 SW2-5 1 OFF OFF OFF OFF OFF 2 O N OFF OFF OFF OFF 3 OF[...]

  • Page 12

    Ta b le E. Switch Settings f or SW2 – D-T ype Control (continued) Receiver Address SW2-1 SW2-2 Switch Setting SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OFF ON ON OFF OFF 53 ON OFF ON OFF ON ON OFF OFF 54 OFF ON ON OFF ON ON OFF OFF 55 ON ON ON O[...]

  • Page 13

    Ta b le E. Switch Settings for SW2 – D-T ype Control (continued) Receiver Address SW2-1 SW2-2 Switch Setting SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 161 ON OFF OFF OFF OFF ON OFF ON 162 OFF ON OFF OFF OFF ON OFF ON 163 ON ON OFF OFF OFF ON OFF ON 164 OFF OFF ON OFF OFF ON OFF ON 165 ON OFF ON OFF OFF ON OFF ON 166 OFF ON ON OFF OFF ON OFF ON 167 ON O[...]

  • Page 14

    SPECIFICA TIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .75-inch (1.91 cm) conduit fitting Pendant: Through 1.5-inch (3.81 cm) NPT pendant mount Pan Movement: 360 ° continuous pan rotation Ve r tical Tilt: Unobstructed +2 ° to -92 ° Manual P an/Tilt Speeds* Pan Spec[...]

  • Page 15

    GENERAL Environment In-Ceiling: Indoor only Pendant: Indoor/outdoor Operating Range In-Ceiling: 32 to 140 ° F (0 to 60 ° C) intermittent operation; 32 to 122 ° F (0 to 50 ° C) continuous operation Pendant Without Heater: 32 to 140 ° F (0 to 60 ° C) absolute maximum operating temperature; 32 to 122 ° F (0 to 50 ° C) sustained maximum operati[...]

  • Page 16

    PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or workmanship for a period of one year after the date of shipment. (559) 292-1981 to obtain a Repair Authorization number ([...]