Pelco C2496M manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C2496M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C2496M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C2496M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C2496M should contain:
- informations concerning technical data of Pelco C2496M
- name of the manufacturer and a year of construction of the Pelco C2496M item
- rules of operation, control and maintenance of the Pelco C2496M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C2496M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C2496M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C2496M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C2496M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ADDENDUM P elco W or ldwide Headquar t ers 3500 Pelco Way • Clovis , California 93612 USA USA & Canada • T el: 800/289-9100 • Fax: 800/28 9-9150 International • T el: 1-559/292-1 981 • Fax : 1-559/348-112 0 www .pelco.com Addendum No. C3409M Date December 22, 2005 Manuals Affected C2462M-B, C2403M-C, C2 410M-H, C2491M-B, C2496M Manual[...]

  • Page 2

    090 Series Camclosure ® Indoor Integrated Camera System ® INST ALLA TION C2462M-B (10/05)[...]

  • Page 3

    2 C2462M-B (10/05) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND WARNINGS .................................................................................... 3 WELCOME ......................................................................................................................................... 4 REMOVE THE BUBBLE .....................[...]

  • Page 4

    C2462M-B (10/05) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and[...]

  • Page 5

    4 C2462M-B (10/05) WELCOME Thank you for purchasing Pelco’ s Camclosure ® Integrated Camera System for indoor applications. The ICS090 Series system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted to the surface of a ceiling/wall or recessed in a ceiling/wall. Prior to installation[...]

  • Page 6

    C2462M-B (10/05) 5 REMOVE THE BUBBLE T urn the bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a non-abrasive surface. If the unit is supplied with a liner , remove the liner before installing the unit. T o remove the liner , gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the b[...]

  • Page 7

    6 C2462M-B (10/05) INST ALL THE BACK BOX The installation methods for the ICS090 Series include the following: • Mount to the surface of a ceiling/wall • Install in a suspended ceiling • Install in a fixed ceiling/wall • Mount to the surface of a 4S standard electrical box • Install in a 4S deep electrical box Select the best method for y[...]

  • Page 8

    C2462M-B (10/05) 7 Figure 2. Ceiling/Wall Installation Installation to Surface of a Ceiling/Wall Refer to Figure 2 for the following steps. Refer to Figure 3 if installing the unit to a concrete ceiling/wall. 1. Pull video and power wires through the ceiling/wall. 2. Connect the video cable/wires. BNC – Connect the BNC connector from the Camclosu[...]

  • Page 9

    8 C2462M-B (10/05) SURF ACE MOUNT RING BACK BO X ST ANDOFF Figure 5. How to Remove Surface Mount Ring from Back Box In-Ceiling Installation – Suspended Ceiling Refer to Figure 4 for the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a four -inch diameter hole in the ceiling tile. 3. Remove the surface mount ring from the bac[...]

  • Page 10

    C2462M-B (10/05) 9 In-Ceiling Installation – Fixed Ceiling/Wall Refer to Figure 6 for the following steps. 1. Cut a four -inch diameter hole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinc[...]

  • Page 11

    10 C2462M-B (10/05) Installation to Surface of a 4S Standard Electrical Box Refer to Figure 7 for the following steps. 1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 2. Connect the video cable/wires. BNC – Connect the BNC connector from the Camclosure to a mating BNC connector . T wisted Pair – Blue wi[...]

  • Page 12

    C2462M-B (10/05) 11 8-32 x 1.00 (SUPPLIED) ADAPTER RING BACK BOX 8-32 X .750 (SUPPLIED) CEILING/ WALL 4S DEEP ELECTRICAL BOX Installation in a 4S Deep Electrical Box Refer to Figure 8 for the following steps. 1. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on[...]

  • Page 13

    12 C2462M-B (10/05) CAMERA POSITIONING Manually rotate and tilt the camera module to position the camera. Do not over -rotate the module. Excessively turning the module in one direction could result in damage to the wiring.     T ilt 140 °  Pan 360 °  Rotation 360 ° Figure 9. How to Position Camera[...]

  • Page 14

    C2462M-B (10/05) 13 Figure 11. Varifocal Lens Adjustments CAMERA ADJUSTMENTS VARIFOCAL LENS ZOOM AND FOCUS ADJUSTMENTS 1. Select a field of view by turning the zoom adjustment ring clockwise/counterclockwise. Refer to Figure 10. 2. T ighten the zoom locking screw . 3. Adjust the focus by moving the focus locking screw clockwise/counterclockwise. 4.[...]

  • Page 15

    14 C2462M-B (10/05) SWITCH SETTINGS Switch Settings for Fixed Focal Length Lens Without Auto Iris Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensa- tion (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that dar[...]

  • Page 16

    C2462M-B (10/05) 15 VERTICAL PHASE ADJUSTMENT (24 V AC OPERA TION ONL Y) When using more than one camera power supply , a brief vertical roll may occur on the monitor when a camera view is switched. T o eliminate vertical roll reverse the 24 V AC connections on one camera. If both cameras are connected to the same transformer , this should solve th[...]

  • Page 17

    16 C2462M-B (10/05) REINST ALL THE DOME DOME LINER INST ALLA TION If the unit is supplied with a dome liner , reinstall the liner before installing the bubble. T o install the liner refer to Figure 13 and do the following: 1. Align the studs located on the camera module with the clips on the liner . 2. Lightly pinch the sides of the liner , opposit[...]

  • Page 18

    C2462M-B (10/05) 17 SERVICE CONNECTOR An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and adjustments. T o use the cable simply plug one end of the cable directly into the service connector of the ICS090 and connect the other end to any standard BNC (VIDEO IN) connector on a monitor . T o assemble a l[...]

  • Page 19

    18 C2462M-B (10/05) SPECIFICA TIONS BACKBOX Electrical Input V oltage: 12 VDC or 24 V AC ( ± 10%), auto-sensing Power Consumption: 3 watts or less Video Connector: BNC General Pan/T ilt Adjustment Pan: 360 ° T ilt: 140 ° (20 ° to 160 ° range) Rotation: 360 ° Construction Back Box and Surface Mount Ring: ABS plastic Bubble: Polycarbonate Finis[...]

  • Page 20

    C2462M-B (10/05) 19 PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years [...]

  • Page 21

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East ®[...]