Pelco C2624M manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C2624M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C2624M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C2624M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C2624M should contain:
- informations concerning technical data of Pelco C2624M
- name of the manufacturer and a year of construction of the Pelco C2624M item
- rules of operation, control and maintenance of the Pelco C2624M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C2624M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C2624M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C2624M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C2624M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® INST ALLA TION FX82012 Unmanaged Ethernet Switch One 10BASE-T/100BASE-TX Port and T wo 100BASE-FX Fiber Ports C2624M (6/07)[...]

  • Page 2

    2 C2624M (6/07) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Overview . . . . . . . . . . . . . . . . . [...]

  • Page 3

    C2624M (6/0 7) 3 List of T ables A TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 B FX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 C Troubleshooting with Front-Panel Indicators . . . . . . . . . . .[...]

  • Page 4

    4 C2624M (6/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation open ings. Inst all in accordance with the manufacturer’ s instructions. 8. Do not install n[...]

  • Page 5

    C2624M (6/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO N[...]

  • Page 6

    6 C2624M (6/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. RADIO AND TELEVIS ION INTERFERENCE T[...]

  • Page 7

    C2624M (6/0 7) 7 Product Overview DESCRIPTION The FX82012 unmanaged Ethernet switch provides one 10BASE-T/100BASE- TX port and two 100BASE-FX fiber ports for the transport of bidi rectional Ethernet data. Available in multimode and single-mode versions, the fiber ports use wavelength di vision multip lexing (WDM), wh ich al lows bidirectional data [...]

  • Page 8

    8 C2624M (6/07) Features of the FX 82012 Ethernet switch include the following: • User -selectable 10BASE-T/100BAS E-TX networking functions: – Autonegotiation between 10 Mbps and 100 Mbps data rates and between full-duplex and half-duplex modes – 10 Mbps or 100 Mbps selectable – Full-duplex or half-duplex mode selectable – Enabling/disab[...]

  • Page 9

    C2624M (6/0 7) 9 MODELS The FX82012 module consists of t he followin g series of models: Multimode Models:* FX82012MSTR-2 Unmanaged Ethernet switch, one 10BASE-T/100BASE-TX port, two multimode ST fiber ports, one fiber per port (total of two fibers) FX82012MSCR-2 U nmanaged Ethernet switch, one 10B ASE-T/100BASE-TX port, two multimode SC fiber port[...]

  • Page 10

    10 C2624M (6/07) FRONT PANEL Figure 3 illustrates the front panel of the FX82012 module. Figure 3. Front Panel of FX82012 Module For detailed information about the front-panel LEDs, refer to the T roubleshooting section. ì RESET BUTTON (restarts the unit) î FIBER FA ILOVER (REDUNDANCY) MODE LED ï 100BASE-FX ST A TUS LED (per fiber port A and B) [...]

  • Page 11

    C2624M (6/0 7) 11 REAR PANEL Figure 4 illustrates the rear panel of the FX82012 module. Figure 4. Rear Panel of FX82012 Module (SC Fiber Connectors Shown) For additional informati on about rear -panel connections, refer to the Installation section. For detailed information about the RJ-45 LEDs, refer to the T roubleshooting section. ì RACK POWER/A[...]

  • Page 12

    12 C2624M (6/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 FX82012 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 -40 x 0.250-inch Phillips pa n head screws with lock wa s[...]

  • Page 13

    C2624M (6/0 7) 13 Using the TX Mode switch, you can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the FX82012 mo dule to automatically negotiate with the device to which the port is connected fo r data rate and duplex modes of operation: 10 Mbps or 100 Mbps d[...]

  • Page 14

    14 C2624M (6/07) SETTING FIBER FAILOVER MODE NOTE: As a matter of convenience, it is recomm ended that y ou set fiber failover (redundancy) mode—if required—befor e mounting the FX8201 2 module into a ra ck or onto a wall. Fiber failover mode is disabled by default. The FX82012 module can operate in fiber failover mode to al low automatic fiber[...]

  • Page 15

    C2624M (6/0 7) 15 Ta b l e B . FX Mode Switch Settings MOUNTING The FX82012 module can be mounted into a rack or c an be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set t he modes of operation for each 10BASE-T/1[...]

  • Page 16

    16 C2624M (6/07) MOUNTING THE FX82012 MODULE TO A WALL The FX82012 module can be mounted to a wall in the following ways: • Using the supplied wall clip fo r attachment of a single module to a wa ll. For installation instructions, refer to the Mounting the FX82012 Module Using the Wall Clip secti on. • Using the optional WM5001 wall mount kits,[...]

  • Page 17

    C2624M (6/0 7) 17 Figure 7. Mounting the FX82012 Module Using the Wall Cl ip UPPER FLANGE VERTI C AL MOUNTING HOLE (2) HORIZONT AL MOUNTING HOLE (2) LOWER FLANGE W ALL C LIP SC REW , PHILLIP S P AN HEAD WITH LO C K W A S HER (2)[...]

  • Page 18

    18 C2624M (6/07) CONNECTIONS Connections to the FX82012 module are made on the rear panel of the modul e (refer to Figure 8). Figure 8. FX82012 Connections (SC Fi ber Connectors Shown) As illustrated in Figure 8, FX82012 c onnections consist of the following: • Power connection – A 12 VDC or 24 VA C power supply can be us ed to power the module[...]

  • Page 19

    C2624M (6/0 7) 19 • Fiber connections – When connecting fiber between FX82012 models, connect fiber port A of one module to fiber port B of another module. Similarly , c onnect fiber port B of one module to fiber port A of another module. Note that ports A and B c onnect fiber between FX82012 models because of fiber wa velength compatibility: ?[...]

  • Page 20

    20 C2624M (6/07) Figure 9. Fiber Port Conn ections in Point-to-Point Application with Redundancy FX MODE POSITION 2: FIBER PORT B IS PRIMARY . FIBER PORT A IS SECONDARY . SECONDARY FIBER LINK PRIMARY FIBER LINK FX MODE POSITION 1: FIBER PORT A IS PRIMARY . FIBER PORT B IS SECONDARY .[...]

  • Page 21

    C2624M (6/0 7) 21 Figure 10. Fiber Port Connections in Samp le Drop-and-Repeat Application FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT .[...]

  • Page 22

    22 C2624M (6/07) T roubleshooting LED indicators on the front and rear panels of the FX82012 module allow you to monitor operational status: • LED indicators on the front panel allow y ou to monitor operating power , fiber redundancy mode status, 100BASE-FX port status, and optic signal/laser status. Refer to T able C for information about the fr[...]

  • Page 23

    C2624M (6/0 7) 23 Fiber Failover Mode LED ( ) Not lit The module is not in fiber redundancy mode. The FX Mode switch is set to position 0. If fiber redundancy is not required, no action is required. If fiber redundancy is required, power off the module, set the FX Mode switch to position 1 or 2 as appropriate, and then power on the module. For deta[...]

  • Page 24

    24 C2624M (6/07) 100BASE-FX Status LED ( ) Green A fiber link is established. — No action required. Flashing green Da ta activity is occurring on the fiber link—data is being transmitted or received. — No action required. Red Far end fault indication (FEFI). The optical signal transmitted from this port is not detected by the remote l ink par[...]

  • Page 25

    C2624M (6/0 7) 25 Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary . Fiber optic cable is not connected. Check fiber optic connections. Fibe[...]

  • Page 26

    26 C2624M (6/07) T able D. T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possible Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Left (Link / Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required. If 10BASE-T operation is not desired, refer to the Set[...]

  • Page 27

    C2624M (6/0 7) 27 RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be established. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device. • Cable is defective. • Cable is not the proper cable type. • [...]

  • Page 28

    28 C2624M (6/07) RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex opera- tion is desired, no action is required. If 10BASE-T full- duplex operation is not desired, refer to the Setting 10BASE-T/100BASE-TX Port Modes of Operation section in this manual [...]

  • Page 29

    C2624M (6/0 7) 29 RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required. If 100BASE-TX full-duplex operation is not desired, refer to the Setting 10BASE-T/100BASE-TX Port Modes of Operation section[...]

  • Page 30

    30 C2624M (6/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired , no action is required. If 10BASE-T half- duplex operation is not desired, refer to the Setting 10BASE-T/100BASE-TX Po[...]

  • Page 31

    C2624M (6/0 7) 31 Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Half-duplex or full-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and [...]

  • Page 32

    32 C2624M (6/07) OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE Model Number Number of Fibers Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance Fiber Port A Fiber Port B Multimode (62.5/125 μm) FX82012MSTR-2 2 (1 per port) 1310/850 nm 850/1310 nm 26 dB † 2 km (1.2 mi) ‡ FX82012MSCR-2 2 (1 per port) 1[...]

  • Page 33

    C2624M (6/0 7) 33 Appendix. RJ-45 Connector Pinouts Figure 11 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 11. RJ-45 MDI/MDI-X Connector Pinouts T able E summarizes RJ-45 MDI/MDI-X connector pinouts. T able E. RJ-45 MDI/MDI-X Connector Pinouts Pin Num ber MDI (Normal Mode) MDI-X (Crossed Mode) 1 RX+ TX+ 2 RX- TX- 3T X + R X + 4 Not used No[...]

  • Page 34

    34 C2624M (6/07) The materials used in the manufacture of this document and its components are compliant to t he requirements of Directive 2002/95/EC. This equipment contains electrica l or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the E ur opean Union rega rding the disposal of waste electrical and[...]

  • Page 35

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment. Exception s to this warrant y are as noted be low: • Five years on fiber o ptic products and TW3 000 Series unshield ed twisted pair tr [...]

  • Page 36

    ® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | G ermany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Ar[...]