Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C454M-C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C454M-C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Pelco C454M-C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Pelco C454M-C should contain:
- informations concerning technical data of Pelco C454M-C
- name of the manufacturer and a year of construction of the Pelco C454M-C item
- rules of operation, control and maintenance of the Pelco C454M-C item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C454M-C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C454M-C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C454M-C.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C454M-C item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
BB14 Series Intercept ® Back Box Installation/ Operation Manual C454M-C (1/98) Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • [...]
-
Page 2
2 Pelco Manual C454M-C (1/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 5 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS ............................... 5 1.2 UNP ACKING INSTRUCTIONS .......................................................... 6 1.3 RECOMMENDED TOOLS [...]
-
Page 3
Pelco Manual C454M-C (1/98) 3 REVISION HISTOR Y Manual # Date Comments C454M — Original version. C454M-A 6/95 Revised to incorporate B.O.M. quantity changes as per ECO# 94-445. Added 4-position terminal block information as per ECO# 94-042. Incorporated new “Front” labeling to B.O.M. as per ECO# 94-192. Updated manual to new style standards. [...]
-
Page 4
4 Pelco Manual C454M-C (1/98) (This page intentionally left blank.)[...]
-
Page 5
Pelco Manual C454M-C (1/98) 5 Please thor oughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Se[...]
-
Page 6
6 Pelco Manual C454M-C (1/98) 1.2 UNP ACKING INSTRUCTIONS Unpack and inspect all parts carefully . Be sure to save the shipping carton and any inserts. They are the safest material in which to make future shipments. If an item appears to have been damaged in shipment, replace it properly in its carton and contact the factory at 1-800-289-9100 or 1-[...]
-
Page 7
Pelco Manual C454M-C (1/98) 7 2.0 DESCRIPTION The BB14 Series of back boxes is part of the IDS14 Intercept ® Series of domes. The IDS14 Series is an integral system that includes a back box (BB14), dome drive or fixed mount (DD14), and dome receiver/driver (DRD14). This manual cover the BB14 Series of back boxes. For installation and operation ins[...]
-
Page 8
8 Pelco Manual C454M-C (1/98) Indoor, Pendant BB14E100 Indoor, black, pendant-mount back box; smoked dome; hard- wire control. (CE, UL) BB14E101 Indoor, black, pendant-mount back box; clear dome; hard-wire control. (CE, UL) BB14E110 Indoor, black, pendant-mount back box; smoked dome; 120 VAC input. (UL) BB14E111 Indoor, black, pendant-mount back bo[...]
-
Page 9
Pelco Manual C454M-C (1/98) 9 3.0 INST ALLA TION 3.1 MOUNTING The Intercept ® Series of domes provide back box configurations for several applica- tions and environments (refer to Figures 12 and 13). Installation instructions for the applications listed below will appear in the following order: 1. Suspended ceiling mounting 2. Hard ceiling mountin[...]
-
Page 10
10 Pelco Manual C454M-C (1/98) 3.1.2 Har d Ceiling Mounting For installing the back box in a hard ceiling , an optional backup plate is provided for applications where additional reinforcement to the ceiling structure is needed. T o mount the back box directly into a hard ceiling, perform the following steps. 1. Determine the location of the back b[...]
-
Page 11
Pelco Manual C454M-C (1/98) 11 3.1.3 Pendant Mounting The pendant back box is designed to be suspended from a suitable length of 1-1/2” pipe threaded at both ends. This pipe can be interfaced to the IWM Series or IDM4018 wall mounts or to the MRW A wall adapter mount or MRCA ceiling adapter mount. T o install the pendant type back box, perform th[...]
-
Page 12
12 Pelco Manual C454M-C (1/98) 3.2 WIRING INSTRUCTIONS How your back box will be wired depends on the type of unit you have: Units with an on-board receiver/driver Units without an on-board receiver/driver (hard-wire applications) Hardwire refers to installations using a remote receiver/driver or a true hardwire controller . Proceed to either Secti[...]
-
Page 13
Pelco Manual C454M-C (1/98) 13 T able A. V ideo Coaxial Cable Requirements Cable T ype* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG1 1/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms All-copper center conductor All-copper braided shield with 95% braid coverage Wire Gauge Maximum distance from transformer to load T able[...]
-
Page 14
14 Pelco Manual C454M-C (1/98) Figure 3. 24 V AC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)[...]
-
Page 15
Pelco Manual C454M-C (1/98) 15 Figure 4. 120 V AC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)[...]
-
Page 16
16 Pelco Manual C454M-C (1/98) Figure 5. 230 V AC Back Box W iring Diagram (for Dome Drives with Integral Receiver/Driver)[...]
-
Page 17
Pelco Manual C454M-C (1/98) 17 3.2.2 Har d-Wir e or Remote Receiver/Driver Refer to Figures 6 and 7 for wiring diagrams. Refer to T able A for the type of video coaxial cable to use. On models for suspended ceilings or hard ceilings, a plate is provided on the top of the back box with 1/2" and 3/4" conduit knockouts. If your back box has [...]
-
Page 18
18 Pelco Manual C454M-C (1/98) Figure 6. Wiring Diagram, Hard-Wire Control with Heater NOTE: For fixed mount or dome drive with blower/heaters and without integral receiver/driver.[...]
-
Page 19
Pelco Manual C454M-C (1/98) 19 Figure 7. W iring Diagram, Hard-W ire Control without Heater NOTE: For use in domes without integral receiver/driver or heaters and blower .[...]
-
Page 20
20 Pelco Manual C454M-C (1/98) 3.2.3 Heater/Blower Kit Field Installation The kits are shipped partially assembled, to complete assembly and to install the heater/blower kit perform the following steps: 1. Place the fan over the four (4) unused internally threaded standof fs located on the back plate (refer to Figure 1 1). Note the arrow indicating[...]
-
Page 21
Pelco Manual C454M-C (1/98) 21 4.0 EXPLODED ASSEMBL Y DIAGRAMS Figure 8. Suspended Ceiling Back Box Exploded Assembly Diagram T able C. Suspended Ceiling Back Box Exploded Assembly Parts List Item Quantity Description Part Number 1 1 T rim ring, white SB262ASSY 2 1 Back box 8144287COMP 3 1 Faceplate, drop ceiling, white 8144169COMP 4 1 Plate, gland[...]
-
Page 22
22 Pelco Manual C454M-C (1/98) Item Quantity Description Part Number 1 1 T rim ring, white SB262ASSY 2 1 Back box 8141202WA 3 1 Plate, gland 8004130COMP 4 4 Receiver ball stud PT180410001 1 Switch, on/of f, SPST (not shown) SWI0201S11N41P 1 Backup plate, optional (not shown) 8004110COMP 1 Acrylic dome, clear (not shown) 81410001-5 Acrylic dome, smo[...]
-
Page 23
Pelco Manual C454M-C (1/98) 23 Figure 10. Pendant Back Box Exploded Assembly Diagram T able E. Pendant Back Box Exploded Assembly Part List Item Quantity Description Part Number 1 1 Bezel, black 8144190BCOMP Bezel, gray 8144190GCOMP 2 1 Back box, pendant, black 8144185BCOMP Back box, pendant, gray 8144185GCOMP 3 1 Cap, pendant, 14", black 8144[...]
-
Page 24
24 Pelco Manual C454M-C (1/98) Figure 1 1. Back Plate Exploded Assembly Diagram[...]
-
Page 25
Pelco Manual C454M-C (1/98) 25 T able F . Back Plate Exploded Assembly Parts List (Figure 1 1) Item Quantity Description Part Number 1 2 Latch backup plate 8004244COMP 2 2 Latch 8004105COMP 3 2 Latch bracket 8004143COMP 4 1 T ransformer (120 VAC model only) TRF21243.30.70F 5 1 25-position connector plug CON10P025Z41T 6 2 Screw, 6-32 ZH20821 1-4 7 1[...]
-
Page 26
26 Pelco Manual C454M-C (1/98) 5.0 SPECIFICA TIONS ELECTRICAL Enclosure Back Box Input Voltage: 24 VAC or 120 VAC Power Requirements Receiver/Driver: 48 vA for 24 VAC and 120 VAC dome drives Blower continuous duty: One (1) at 30 cfm, 1.92 watts, 24 VDC One (1) at 33 cfm, 6.7 watts, 120 VAC 60 Hz One (1) at 27 cfm, 8.9 watts 230 VAC 50 Hz Heaters 24[...]
-
Page 27
Pelco Manual C454M-C (1/98) 27 Figure 12. Suspended/Hard Ceiling Dimension Drawings Figure 13. Pendant-Mount Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES[...]
-
Page 28
28 Pelco Manual C454M-C (1/98) 6.0 WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one (1) year after the date of shipment. Exceptions to this warranty are as noted below: • T wo (2) years on all standard motorized and fixed focal l[...]