Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Pelco c561m-h, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco c561m-h one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Pelco c561m-h. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Pelco c561m-h should contain:
- informations concerning technical data of Pelco c561m-h
- name of the manufacturer and a year of construction of the Pelco c561m-h item
- rules of operation, control and maintenance of the Pelco c561m-h item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco c561m-h alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco c561m-h, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco c561m-h.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco c561m-h item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INST ALLA TION/OPERA TION WCS1-4 Environmental Power Supply C561M-H (3/08)[...]
-
Page 2
[...]
-
Page 3
C561M-H (3/08) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified service personnel and conform to all local codes. 6. Use only installation methods and materials capable of supporting four times the maximum specif[...]
-
Page 4
4 C561M-H (3/08) Description The WCS1-4 is a single power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 power supply has one fused outpu t and is capa ble of ha ndling up to 4 amps (100 VA) of total load. The unit features[...]
-
Page 5
C561M-H (3/08) 5 FUSE INSTALLATION The WCS1-4 power supply is shipped from the factor y with a 1.6 A fuse installed for 100/120 V AC inp ut power . T o use input power of 240 VAC, change the 1.6 A fuse to a 500 mA fuse (supplied). T o change the fuse remove the lid to the fuse holder (refer to Figure 4) located inside the power supply and then inst[...]
-
Page 6
6 C561M-H (3/08) OUTPUT WIRING T o install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed fo r your camera, dome, or positio ning system. Refer to Figure 4, for the proper connector strip connections. 2. Attach one output wire to e[...]
-
Page 7
C561M-H (3/08) 7 CABLE CONNECTIONS AND REQUIREMENTS The following are the recommended maximum distances to wire the WCS1-4 to a Spectra or Esprit positioning system. T o determine the correct voltage tap: 1. Pick the unit type. 2. Find the wire gauge used (22 gauge is not recommended). Determine which secondary output tap (A, B, or C) is appropriat[...]
-
Page 8
8 C561M-H (3/08) Specifications ELECTRICAL Input V oltage Selectable 100, 120, 240 VAC, 50/60 Hz through the Primary Line Input connector strip Output V oltage/Power Selectable 24 V AC (T ap A), 26 V AC (T ap B), or 28 V AC (T a p C) at 100 V A through the Secondary Output T ap’ s connector strip Fusing 1 fuse. Select from one of the following su[...]
-
Page 9
C561M-H (3/08) 9 4.01 (10.3) 6.50 (16.5) 7.65 (19.4) 7.32 (18.8) 6.63 (16.8) 6.71 (17.0) 4.50 (11.4) NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.[...]
-
Page 10
10 C561M-H (3/08) REVISION HISTORY Manual # Date Comment s C561M 11/97 Original version. C561M-A 12/98 Changed model n umber . Revised T able A to update vA ratings for Spectr a. 5/00 Changed model numbe r . C561M-B 6/00 Revised manual to s upport changes required for UL listing. C561M-C 5/03 Revised Wiring Distance se ction to include Spectra III [...]
-
Page 11
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or workma nship for a period of one year after the date o f shipment. Exception s to this warranty are as not ed below: • Five years on fiber opt ic products and TW3 000 Series unshield ed twisted pair (UT[...]
-
Page 12
Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Arab Emirates |[...]