Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Pelco ECP190, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco ECP190 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Pelco ECP190. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Pelco ECP190 should contain:
- informations concerning technical data of Pelco ECP190
- name of the manufacturer and a year of construction of the Pelco ECP190 item
- rules of operation, control and maintenance of the Pelco ECP190 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco ECP190 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco ECP190, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco ECP190.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco ECP190 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
S T AND A LONE A CCESS C ONTROL ECP190 / ECP290 DOOR CONTROLLERS ® Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity . ECP190 / ECP290 DOOR CONTROLLERS Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity . nacd.co .uk[...]
-
Page 2
2 contents Explanation of Noralsy ® Access P asses 3 General Door Controller Inf ormation 4 ECP 190 Door Controller schematic 5 ECP 290 Door Controller schematic 6 How to use the T elpro ™ progr ammer 7-8 Programming Set-up on installation 9-10 Block loading of Access P asses 10 Deleting individual Access P asses 10-11 V alidating individual Acc[...]
-
Page 3
3 N ORALSY ® A CCESS P ASSES Site Code The number of each and e very Access Pass is visib le. Just b y looking at it, y ou kno w which Access Pass y ou have . Noralsy ® pre-number each Access P ass because this is the only way y ou can know f or sure what you ha ve received, what y ou need to program the system to accept (or , reject in the case [...]
-
Page 4
4 ® Noralsy ECP Door Controllers 1 2 3 1 2 4 5 6 3 1 2 3 1 2 4 3 1 2 3 1 2 4 5 3 1 2 3 1 2 3 1 2 1 2 3 1 2 4 3 1 2 4 5 3 1 2 4 5 6 3 1 2 4 5 6 7 3 1 2 4 5 6 7 8 3 1 2 1 2 4 5 6 3 65432 1 654321 1 Standardisation of T erminal Numbering Place Noralsy unit on a flat surface with PCB facing skywards. V iew terminal blocks fr om the outside looking in.[...]
-
Page 5
12345 6 = 12345 6 32 1 21 123456 32 1 1O N 5 4 3 2 1 1 2 3 4 5 = 32 1 2 1 (—) (+) 5 ® ECP190 Door Controller for 1 n 0 Door/Access Point ■ Capacity 999 Users ELEC/INST/801 Supply 12V DC ± 10% Dimensions 103 L x 106 W x 83 D (6 DIN units) W eight 0.44 Kg Power Consumption 55mA quiescent CE Norms EN50082, EN55022 Class B ECP 190 Door Controller[...]
-
Page 6
6 ® ECP290 Door Controller for 2n 0 Doors/Access Points ANTI-P ASSBA CK FEA TURE A V AILABLE Supply 12V DC ± 10% Dimensions 163 L x 106 W x 83 D (10 DIN units) W eight 0.56 Kg Power Consumption 160mA quiescent CE Norms EN50082, EN55022 Class B ECP 290 Door Controller ■ Capacity 999 Users per door ELEC/INST/830 * If not used, link terminals 3 &a[...]
-
Page 7
7 ® Programming Stand-Alone Access Control Systems using TELPRO™ Programmer . MLP3 Proximity MIR Infra-Red MILB Card Reader LB20 Swipe Card ECP190 ECP290 ECP100 ECP200 Access Contr ol Modules, Readers, Receiver s without integral Infra-Red Access Contr ol Modules with integral Infra-Red The TELPRO™ Programmer is supplied with a connector cable[...]
-
Page 8
Important : Each press of a button is confirmed (as r eceived) by the r eader/r eceiver by a single beep. Press the TELPRO ™ buttons gently . Programming using TELPRO ™ as a remote wire-free programmer . Remote Programming Range: Infra-Red Receiver 20 cms - 5 metres Proximity Reader 5 cms - 10 cms How to use the TELPRO: Flick TELPRO switch to O[...]
-
Page 9
9 PROGRAMMING 08 Example Basic configuration, just do it! Basic configuration, just do it! seconds ECP Door Controller with ACCESS P ASS CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected via the TELPRO programming keypad. ■ Site Code is always a 5 digit number . ■ Site Code is always stored in Slot N o . 01. ■ Master Code (Programmi[...]
-
Page 10
10 *See Tip Wizard on page 13 * STEP 4 Y ou must now inform the Door Controller of the Site Code of the Access Passes supplied. The Site Code is always stored in Slot N o . 01. The Site Code is always a 5 digit number . Check the Access Pass Information Sheet delivered with the Access Passes. It will tell you the Site Code of the Access Passes deli[...]
-
Page 11
11 After a beep enter on the TELPRO: A sharp beep confirms that you have correctly deleted Holder Number 074. Pr ogramming mode beep - every 4 seconds - resumes. Example C: V alidation of 1n o . Access Pass Y ou have just received the additional Access Pass order ed for Alan Jones who had lost his earlier in the week. The last 3n o . digits on the [...]
-
Page 12
12 ECP290 D OOR C ONTROLLER FOR 2 D OORS – I MPORT ANT I NFORMA TION FLICKING PROGRAMMING SWITCH SW1. The access control readers on both doors will star t to beep ev er y 4 seconds indicating programming mode status . Only 1 n o . access point (door) can be programmed at a time . IF USING THE TELPRO PROGRAMMER IN WIREFREE INFRA-RED MODE: Simply p[...]
-
Page 13
13 Mode 4 - Dual Security , Access Pass + K e ypad Code 00 4 00508 = Set-Up , Mode 4 È Rela y output time in seconds User required to present a valid access pass and then enter a v alid code or vice versa in order to gain access . A maximum of 27n o .5 digit ke ypad codes can be set at any one time. An y 1no . of these ke ypad codes together with [...]
-
Page 14
14 ® ® Noralsy® ECP Door Controller 32 1 2 1 32 1 654321 65432 1 1 2 4 5 6 3 6 5 3 2 1 4 32 1 + 21 32 1 (—) (+) Fail Safe Locking ECP190 Door Controller ECP190 Door Controller ECP190 Door Controller Automation Control / V olt Free Entrance/Exit Access point requiring access contr ol on both sides of the door , gate or barrier . ie. Access Pass[...]
-
Page 15
15 ® ® 32 1 (–) (+) 21 32 1 Locking ECP190 Door Controller Noralsy® ECP Door Controller DIN Rail Mounting W all Mounting DIN Rail ELEC/INST/805 ELEC/INST/806 ELEC/INST/807[...]
-
Page 16
® ® 16 Noralsy® DIN Rail Power Supplies ELEC/INST/808 ELEC/INST/809 ELEC/INST/810 ELEC/INST/811 ARE121 12V AC/DC 1 AMP MAXIMUM OUTPUT ARE122 12V DC 2 AMP MAXIMUM OUTPUT ARS122 12V DC 2 AMP MAXIMUM OUTPUT AB126 BA TTER Y ST ANDBY[...]
-
Page 17
17 ® Noralsy® Powering ECP Door Controller(s) using Noralsy® DIN Rail Power Supply Units ELEC/INST/812 ARE121 + ECP190 ARE122 + ECP290 ELEC/INST/812A[...]
-
Page 18
18 ECP190 DOOR CONTROLLER with KEYP AD ACCESS CODE CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected directly via the keypad. ■ Master Code (Programming Access Code) is always a 5 digit number . ■ Master Code is always stored in Slot N o . 06. ■ Keypad Access Codes are always 5 digit numbers. ■ Keypad Access Codes can be stored in[...]
-
Page 19
19 After a beep enter on the keypad: A sharp beep confirms that you have deleted Alan’ s code. Programming mode beep - every 4 seconds - resumes. After a beep enter on the keypad: A sharp beep confirms that you have deleted Alex’ s code. Programming mode beep - every 4 seconds - resumes. Note 1. Y ou do not need to know the actual code itself w[...]
-
Page 20
N.A.C.D. Limited Unit 10, Avebury Court, Mark Road, Hemel Hempstead, Her ts HP2 7T A. TEL: 01442 211848 F AX: 01442 212776 EMAIL: sales@nacd.co.uk WEB: www.nacd.co.uk Our policy is one of continuous product impr ovement, we reserve the right to change specifications and prices without notice. All information is given in good faith. No responsibilit[...]