Pelco FR8301 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco FR8301, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco FR8301 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco FR8301. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco FR8301 should contain:
- informations concerning technical data of Pelco FR8301
- name of the manufacturer and a year of construction of the Pelco FR8301 item
- rules of operation, control and maintenance of the Pelco FR8301 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco FR8301 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco FR8301, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco FR8301.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco FR8301 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® ® INST ALLA TION FT8301/FR8301 Fiber T ransmitter and Receiver Single-Channel Digitally Encoded V ideo C1641M-A (3/05)[...]

  • Page 2

    2 C1641M-A (3/05) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product Overview . . . . . . . . . . . . . . . . .[...]

  • Page 3

    C1641M-A (3/05) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install nea[...]

  • Page 4

    4 C1641M-A (3/05) CAUTION: These servicing instructions are for use by qualifi ed service personnel only. To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualifi ed to do so. The product and/or manual may bear the following marks: This symbol indicates that danger[...]

  • Page 5

    C1641M-A (3/05) 5 Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE Thi[...]

  • Page 6

    6 C1641M-A (3/05) Product Overview DESCRIPTION The FT8301/FR8301 fi ber transmitter and receiver provide the ability to transmit one composite video channel over one optical fi ber (refer to Figure 1). Figure 1. Single-Channel Video FT8301 T ransmitter and FR8301 Receiver Features of the FT8301/FR8301 fi ber optic transmission system include the[...]

  • Page 7

    C1641M-A (3/05) 7 MODELS The FT8301/FR8301 fi ber transmitter and receiver consist of the following series of models: Multimode Models: FT8301MST Single-channel fiber optic video transmitter; multimode, ST connector; transmission distance up to 2 km FR8301MSTR Single-channel fiber optic video receiver; multimode, ST connector; transmission dista[...]

  • Page 8

    8 C1641M-A (3/05) FRONT PANEL The front panel of the FT8301 transmitter and the FR8301 receiver provides LED indicators that allow you to monitor signal status and operating power. The following sections provide a view of the front panel of the FT8301 transmitter and the FR8301 receiver. FRONT PANEL - FT8301 T RANSMITTER Figure 2 illustrates the fr[...]

  • Page 9

    C1641M-A (3/05) 9 FRONT PANEL - FR8301 RECEIVER Figure 3 illustrates the front panel of the FR8301 receiver. Figure 3. Front Panel of FR8301 Receiver  VIDEO PRESENT LED  CARRIER DETECT LED  POWER LED (Pelco badge) For detailed information about the front-panel indicators, refer to the T roubleshooting section.   [...]

  • Page 10

    10 C1641M-A (3/05) REAR PANEL Connections to the FT8301 transmitter and the FR8301 receiver are made to the rear panel of the modules. The following sections provide a view of the rear panel of the FT8301 transmitter and the FR8301 receiver . REAR PANEL - FT8301 T RANSMITTER Figure 4 illustrates the rear panel of the FT8301 transmitter. Figure 4. R[...]

  • Page 11

    C1641M-A (3/05) 11 REAR PANEL - FR8301 RECEIVER Figure 5 illustrates the rear panel of the FR8301 receiver. Figure 5. Rear Panel of FR8301 Receiver  RACK POWER/ALARM CONNECTOR, 4-pin connector for power/alarm connection of rack-mounted module  ST ANDALONE POWER CONNECTOR, 2-pin connector for power connection of standalone module; removable ma[...]

  • Page 12

    12 C1641M-A (3/05) Installation PACKAGE CONTENTS The following items are supplied: • With the FT8301 transmitter: 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European confi gurations); 100-240 VAC input, 12 VDC output 1 FT8301/FR8301 Fiber T ransmitter and Receiver Installation manual (this m[...]

  • Page 13

    C1641M-A (3/05) 13 MOUNTING THE FR8301 RECEIVER The following sections provide information about mounting the FR8301 receiver into a rack or onto a wall. Mounting the FR8301 Receiver into a Rack The FR8301 receiver can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment [...]

  • Page 14

    14 C1641M-A (3/05) Mounting the FR8301 Receiver Using the Wall Clip NOTE: Before mounting the FR8301 receiver to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for making the various rear - panel cable connections. To attach the FR8301 receiver to a wall using the supplied wall clip, refer to Figure 7 [...]

  • Page 15

    C1641M-A (3/05) 15 CONNECTIONS Connections to the FT8301 transmitter and the FR8301 receiver are made on the rear panel of the modules and consist of the following: • Power connection NOTE: A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when used as a standalone module. A 12 VDC power supply is provided. If a 24 V A[...]

  • Page 16

    16 C1641M-A (3/05) CONNECTING THE FR8301 RECEIVER Figure 9 illustrates FR8301 receiver connections. Figure 9. FR8301 Receiver Connections POWER/ALARM CONNECTION FOR RACK-MOUNTED MODULE* FIBER OPTIC CABLE COAXIAL CABLE † POWER CONNECTION FOR STANDALONE MODULE† *REFER TO THE RK5000PS-3U/RK5000-3U FIBER RACK MOUNT CHASSIS INSTALLATION MANUAL FOR I[...]

  • Page 17

    C1641M-A (3/05) 17 T roubleshooting LED indicators on the front panel of the FT8301 transmitter/FR8301receiver (refer to Figure 2 and to Figure 3, respectively) allow you to monitor signal status and operating power . T able A provides information about the front-panel indicators and associated troubleshooting guidelines. T able A. T roubleshooting[...]

  • Page 18

    18 C1641M-A (3/05) Video Present LED Green Incoming video signal is present on the channel. – No action required. Not lit on transmitter Incoming video signal is not present on the channel. Video source is not powered on. Check power connection to the video source. Video source is not connected to the transmitter . Check BNC connections. Coaxial [...]

  • Page 19

    C1641M-A (3/05) 19 Carrier Detect LED (Receiver Only) Green The optical signal is being received from the transmitter . – No action required. Red The optical signal is not being received from the transmitter . T ransmitter is not powered on. Check power connections. Replace power supply if necessary . Fiber optic cable is not connected. Check fi[...]

  • Page 20

    20 C1641M-A (3/05) Specifications VIDEO Number of Channels 1 Modulation T ype Pulse code modulation, 8-bit resolution Video Input 1.0 Vp-p, 75 ohms; NTSC, PAL, and SECAM Bandwidth 6.5 MHz Gain Unity Differential Gain <2% Differential Phase <1° T ilt <1% Signal-to-Noise Ratio >60 dB (CCIR weighted) GENERAL Operating T emperature -40° [...]

  • Page 21

    C1641M-A (3/05) 21 OPTICAL POWER BUDGET , TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT Fiber Wavelength Optical Power Budget Maximum T ransmission Distance Laser Class 1 Limit* Multimode (62.5/125 µm) 850 nm 15 dB † 2 km (1.2 mi) †† <0.78 mW 1310 nm 20 dB † 6 km (3.7 mi) †† <15.6 mW Single-mode (9/125 µm) 1310 nm 20 dB 30 km ([...]

  • Page 22

    [...]

  • Page 23

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products and the following fixed camera model[...]

  • Page 24

    ® United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East Worldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001[...]