Go to page of
Similar user manuals
-
Switch
Pelco CM8500
16 pages 2.61 mb -
Switch
Pelco SX8205R
24 pages 0.67 mb -
Switch
Pelco CM6700
44 pages 0.97 mb -
Switch
Pelco RB115
2 pages 0.04 mb -
Switch
Pelco 100BASE-TX
40 pages 1.59 mb -
Switch
Pelco c2626M
24 pages 0.67 mb -
Switch
Pelco CM6800-32X6
80 pages 2.16 mb -
Switch
Pelco C549M-A
41 pages 4.14 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Pelco FX82052, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco FX82052 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Pelco FX82052. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Pelco FX82052 should contain:
- informations concerning technical data of Pelco FX82052
- name of the manufacturer and a year of construction of the Pelco FX82052 item
- rules of operation, control and maintenance of the Pelco FX82052 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco FX82052 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco FX82052, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco FX82052.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco FX82052 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
® INST ALLA TION FX82052 Unmanaged Ethernet Switch Five 10BASE-T/100BASE-TX Ports and T wo 100BASE-FX Fiber Ports C2607M (2/07)[...]
-
Page 2
2 C2607M (2/07) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Overview . . . . . . . . . . . . . . . . . [...]
-
Page 3
C2607M (2/0 7) 3 List of T ables A TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 B FX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 C Troublesh ooting with Front-Pane l Indi cators . . . . . . . [...]
-
Page 4
4 C2607M (2/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Inst all in accordance with the manufacturer’ s instructions. 8. Do not install ne[...]
-
Page 5
C2607M (2/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO N[...]
-
Page 6
6 C2607M (2/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. RADIO AND TELEVIS ION INTERFERENCE T[...]
-
Page 7
C2607M (2/0 7) 7 Product Overview DESCRIPTION The FX82052 unmanaged Ethernet switch provides five 10BASE-T/100BASE-TX ports and two 100BASE-FX fiber ports for the transport of bidirectional Ethernet data. The FX82052 switch is available in versions that accept one or two multimode or single-mode fibers per fiber port. The FX82052 switch can be used[...]
-
Page 8
8 C2607M (2/07) Figure 1. Point-to-Point and Drop-and-Repe at Appl ications (One Fiber per Fiber Port) Figure 2. Point-to-Point and Drop-and-Repeat Ap pl ications (T wo Fibers per Fiber Port) POINT -TO-POINT APPLICA TION WITH FIBER REDUNDANCY FX82052-2 FX82052-2 FIVE 10/100 Mbps CONNECTIONS FIVE 10/100 Mbps CONNECTIONS ONE FIBER (REDUNDANT) ONE FIB[...]
-
Page 9
C2607M (2/0 7) 9 Features of the FX 82052 Ethernet switch include the following: • User -selectable network ing functions for each 10BASE-T/100BASE-TX port: – Autonegotiation between 10 Mbps and 100 Mbps data rates and between full-duplex and half-duplex modes – 10 Mbps or 100 Mbps selectable – Full-duplex or half-duplex mode selectable –[...]
-
Page 10
10 C2607M (2/07) MODELS The FX82052 module consists of t he followin g series of models: FX82052, -2 MODELS * Multimode Models FX82052MSTR-2 Unmanaged Ethernet switch, five 10BA S E-T/100BASE-TX ports, two multimode ST fiber ports, one fiber per port (total of two fibers) FX82052MSCR-2 Unmanaged Ethernet swi tch, five 10BASE-T/100BASE-TX ports, two[...]
-
Page 11
C2607M (2/0 7) 11 FRONT PANEL Figure 3 illustrates the front panel of the FX82052 module. Figure 3. Front Panel of FX82052 Module For detailed information about t he front-panel LEDs, refer to T roubleshooting on page 26. ì Reset Button: Restarts the un it î Fiber Failover: Fiber Redundancy Mode LED ï 100BASE-FX Status LED: Per fiber port A and [...]
-
Page 12
12 C2607M (2/07) REAR PANEL FX82052 REAR PANEL, -2 MODELS Figure 4 illustrates the rear panel of the FX82052 module contai ning five 10BASE-T/100BASE-TX ports and two 100BASE-FX fiber ports that each accept one fiber (-2 mode ls). Figure 4. Rear Panel of FX82052 Modul e, -2 Models (SC Fiber Connectors Shown) For additional information about r ear -[...]
-
Page 13
C2607M (2/0 7) 13 FX82052 REAR PANEL, -4 MODELS Figure 5 illustrates the rear panel of the FX82052 module contai ning five 10BASE-T/100BASE-TX ports and two 100BASE-FX fiber ports that each accept two fibers (-4 models). Figure 5. Rear Panel of FX82052 Modul e, -4 Models (SC Fiber Connectors Shown) For additional information about r ear -panel conn[...]
-
Page 14
14 C2607M (2/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 FX82052 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4-40 x 0.250-inch Phillips pa n he ad screws with lock wa s[...]
-
Page 15
C2607M (2/0 7) 15 Using the TX Mode switch for a parti cular port, y ou can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the FX82052 mo dule to automatically negotiate with the device to which the port is connected fo r data rate and duplex modes of operatio[...]
-
Page 16
16 C2607M (2/07) Ta b l e A . TX Mode Switch Settings SETTING FIBER FAILOVER MODE NOTE: As a matter of convenience, it is recomm ended that y ou set fiber failover (redundancy) mode—if required—befor e mounting the FX8205 2 module into a ra ck or onto a wall. Fiber failover mode is disabled by default. The FX82052 module can operate in fiber fa[...]
-
Page 17
C2607M (2/0 7) 17 Figure 7. FX Mode Switch Ta b l e B . FX Mode Switch Settings FX Mode Switch Position Mode of Operation 0 Independent A & B: Sets fiber po rts A and B in nonredundant mode (default setting). 1 Auto Failover , A is Primary: Sets fiber ports A and B in redundant mode. Port A connects to the primary fiber link, and Port B connect[...]
-
Page 18
18 C2607M (2/07) MOUNTING The FX82052 module can be mounted into a rack or c an be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set t he modes of operation for each 10BASE-T/100BASE-TX port and the fib er failover[...]
-
Page 19
C2607M (2/0 7) 19 Mounting the FX82052 Module Using the W all Clip NOTE: Before mounting the FX82052 module to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for ma king the various rear- panel cable connections. T o attach the FX82052 module to a wall using the supplied wall clip, refer to Figure 8 an[...]
-
Page 20
20 C2607M (2/07) CONNECTIONS Connections to the FX82052 module are made on the rear panel of the module. Refer to Figure 9 and to Figure 10 for illustrations of connections to FX82052, -2 models and FX82052, -4 models, respectively . Figure 9. FX82052 Connections, -2 Models (SC Fiber Connectors Shown) Figure 10. FX82052 Connections, -4 Models (SC F[...]
-
Page 21
C2607M (2/0 7) 21 As illustrated in Figure 9 and in Figure 10, FX82052 connections consis t of the fo llowing: • Power connection – A 12 VDC or 24 VA C power supply can be us ed to power the module when used as a stand-alone unit. A 12 VDC po wer supply is provided. If a 24 V AC power supply is used, the power supply must be a Listed Direct Plu[...]
-
Page 22
22 C2607M (2/07) Figure 11. Fiber Port Connections in Point-to-Po int Application with Redundancy , -2 Models FX MODE POSITION 2: FIBER PORT B IS PRIMARY . FIBER PORT A IS SECONDARY . SECONDARY FIBER LINK PRIMARY FIBER LINK FX MODE POSITION 1: FIBER PORT A IS PRIMARY . FIBER PORT B IS SECONDARY .[...]
-
Page 23
C2607M (2/0 7) 23 Figure 12. Fiber Port Con nections in Sample Dr op-and-Repeat Application, -2 Models FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT .[...]
-
Page 24
24 C2607M (2/07) Figure 13. Fiber Port Connections in Point-to-Po int Application with Redundancy , -4 Models FX MODE POSITION 2: FIBER PORT B IS PRIMARY . FIBER PORT A IS SECONDARY . SECONDARY FIBER LINK (TWO FIBERS) PRIMARY FIBER LINK (TWO FIBERS) FX MODE POSITION 1: FIBER PORT A IS PRIMARY . FIBER PORT B IS SECONDARY .[...]
-
Page 25
C2607M (2/0 7) 25 Figure 14. Fiber Port Con nections in Sample Dr op-and-Repeat Application, -4 Models FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT . FX MODE POSITION 0: FIBER PORTS A AND B ARE INDEPENDENT .[...]
-
Page 26
26 C2607M (2/07) T roubleshooting LED indicators on the front and rear panels of the FX82052 module allow you to monitor operational status: • LED indicators on the front panel allow y ou to monitor operating power , fiber redundancy mode status, 100BASE-FX port status, and optic signal/laser status. Refer to T able C for information about the fr[...]
-
Page 27
C2607M (2/0 7) 27 Fiber Failover Mode LED ( ) Not lit The module is not in fiber redundancy mode. The FX Mode switch is set to position 0. If fiber redundancy is not required, no action is required. If fiber redundancy is required, power off the module, set the FX Mode switch to position 1 or 2 as appropriate, and then power on the module. For deta[...]
-
Page 28
28 C2607M (2/07) 100BASE-FX Status LED ( ) Green A fiber link is established. — No action required. Flashing green Da ta activity is occurring on the fiber link; data is being transmitted or received. — No action required. Red Far end fault indication (FEFI). The optical signal transmitted from this port is not detected by the remote l ink part[...]
-
Page 29
C2607M (2/0 7) 29 Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary . Fiber optic cable is not connected. Check fiber optic connec- tions. Fi[...]
-
Page 30
30 C2607M (2/07) T able D. T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possible Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Left (Link / Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required. If 10BASE-T operation is not desired, refer to Setting[...]
-
Page 31
C2607M (2/0 7) 31 RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be estab- lished. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device. • Cable is defective. • Cable is not the proper cable type. ?[...]
-
Page 32
32 C2607M (2/07) RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex operation is desired, no action is required. If 10BASE-T full- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 14 for information. F[...]
-
Page 33
C2607M (2/0 7) 33 RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required. If 100BASE-TX full-duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 14 [...]
-
Page 34
34 C2607M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required. If 10BASE-T half- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Mo[...]
-
Page 35
C2607M (2/0 7) 35 Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Half-duplex or full-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and [...]
-
Page 36
36 C2607M (2/07) OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE FX82052, -2 Models Model Number Number of Fibers Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance Fiber Port A Fiber Port B Multimode (62.5/125 μm) FX82052MSTR-2 2 (1 per port) 1310/850 nm 850/1310 nm 26 d B † 2 km (1.2 mi) ‡ FX82052MSC[...]
-
Page 37
C2607M (2/0 7) 37 FX82052, -4 Models Model Number Number of Fibers Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance Fiber Port A Fiber Port B Multimode (62.5/125 μm) FX82052MSTR-4 4 (2 per port) 1310/1310 nm 1310/1310 nm 26 dB † 6 km (3.7 mi) ‡ FX82052MSCR-4 4 (2 per port) 1310/1310 nm 1310/1310 nm 26 dB † [...]
-
Page 38
38 C2607M (2/07) Appendix. RJ-45 Connector Pinouts Figure 15 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 15. RJ-45 MDI/MDI-X Connector Pinouts T able E summarizes RJ-45 MDI/MDI-X connector pinouts. T able E. RJ-45 MDI/MDI-X Connector Pinouts Pin Num ber MDI (Normal Mode) MDI-X (Crossed Mode) 1 RX+ TX+ 2 RX- TX- 3T X + R X + 4 Not used Not[...]
-
Page 39
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment. Exception s to this warrant y are as noted below: • Five years on fiber o ptic products and TW3 000 Series unshield ed twisted pair tr a[...]
-
Page 40
® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Ara[...]