Pentair 4HP-VD - 3' STD manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pentair 4HP-VD - 3' STD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pentair 4HP-VD - 3' STD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pentair 4HP-VD - 3' STD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pentair 4HP-VD - 3' STD should contain:
- informations concerning technical data of Pentair 4HP-VD - 3' STD
- name of the manufacturer and a year of construction of the Pentair 4HP-VD - 3' STD item
- rules of operation, control and maintenance of the Pentair 4HP-VD - 3' STD item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pentair 4HP-VD - 3' STD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pentair 4HP-VD - 3' STD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pentair service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pentair 4HP-VD - 3' STD.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pentair 4HP-VD - 3' STD item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    P/N 350039 Rev. C 8-24-06 1 OptiFlo ® Plastic Pump for Aboveground Pools Installation, Operation & Service Manual Pentair Water Pool and Spa, Inc. 1620 Hawkins Ave., Sanford, NC 27330 • 800-831-7133 or (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • 800-831-7133 or (805) 553-5000 Visit us on the Internet at: www.pentairpoo[...]

  • Page 2

    P/N 350039 Rev. C 8-24-06 2 OptiFlo ® Engineered Plastic Pump Installation, Operation & Service Manual T able of Contents SECTION I. HOW YOUR PUMP WORKS ............................................................................................... 3 SECTION II. INST ALLA TION ...................................................................[...]

  • Page 3

    P/N 350039 Rev. C 8-24-06 3 W ARNING To reduce the risk of electrical shock, do not use an extension cord to connect unit to electric supply; provide a properly located outlet. W ARNING For continued protection against possible electrical shock, this unit is to be mounted to the base in accordance with the installation instructions. Important Notic[...]

  • Page 4

    P/N 350039 Rev. C 8-24-06 4 4. Provide space and lighting for routine maintenance access. Do not mount electrical controls directly over pump. 5. The pump should be installed as near to the pool or spa as practical. Avoid installing the pump above the water level . Suction lifts of more than 1/2 foot will cause very long priming times, and potentia[...]

  • Page 5

    P/N 350039 Rev. C 8-24-06 5 17 . The pump motor must be wired for the proper voltage in accordance with the wiring diagram supplied with the motor. Wiring the motor with the incorrect supply voltage will cause damage to the motor and void the warranty. 1 8 . The wiring to the motor should be kept as short as possible and large enough NOT to cause a[...]

  • Page 6

    P/N 350039 Rev. C 8-24-06 6 INITIAL START-UP: 1. Relieve all system pressure and open all air bleeders on total hydraulic system prior to starting the pump. See filter owner's manual. 2. Ensure that all fittings, clamps, closures and couplings are tight and in accordance with equipment manufacturer's recommendations. 3. Open suction and d[...]

  • Page 7

    P/N 350039 Rev. C 8-24-06 7 4. Use extreme care when handling the mechanical seal. The mating seal surfaces are polished and are easily damaged. 5. The mechanical seal can be changed without disconnecting piping by removing 4 bolts (see item 14 on page 9) and pulling the motor with pump seal plate and impeller assembly away from front pump housing [...]

  • Page 8

    P/N 350039 Rev. C 8-24-06 8 SECTION VI. TROUBLESHOOTING GUIDE The following are some common causes of problems that may arise. PROBLEM CAUSE REMEDY Pump will not prime. No water in strainer pot. Add water to pot. Strainer pot lid is not tight. T ighten lid. Damaged lid o-ring. Replace o-ring. W ater level is below skimmer . Adjust pool water level.[...]

  • Page 9

    P/N 350039 Rev. C 8-24-06 9 SECTION VII. TECHNICAL DATA REPLACEMENT PARTS 9 7 11 8 4 1 14 5 12 10 15 2 6 3 13 Item No. Part No. D escription 1 357161 D r a i n P l u g, 3 r eq . 2 354545 Mechanical Seal 3 354552 I mpeller 3/4 hp 3 350017 Impeller 1 hp 3 350018 I m peller 1-1/2 hp 4 1921 15 O -ring, 3 req. 5 357213 V olute & Pot Assembly HD 6 35[...]

  • Page 10

    P/N 350039 Rev. C 8-24-06 10 10 9 8 7 6 5 4 3 2 1 REPLACEMENT PARTS (BASE MOUNTED UNITS) For cord and plug connected units, the base should be mounted as shown. Suction V ertical Discharge 7.75" 4.09" 3.50" 7.26" 10.00" 9.33" Item No. Pa rt No. Description 1 354621 Enclosure Housing 2 356436 Motor 3/4 hp, 48 Frame 2 35[...]

  • Page 11

    P/N 350039 Rev. C 8-24-06 11 PUMP CURVES Pentair Pool Products ® OptiFlo ® Series 50 Hz Pump Curves 0 5 10 15 20 25 30 35 01 0 20 30 40 50 60 70 80 Flow Rate in US GPM Total Dynamic Head in Ft. of Water METERS OF WA TER CUBIC METERS PER HOUR 3/4 HP 3/4 HP 1 HP 1 HP 1.5 HP 1.5 HP 3/4 HP 1 HP 1.5 HP 0 2 4 6 8 10 0 5 10 15 Pentair Pool Products ® O[...]

  • Page 12

    P/N 350039 Rev. C 8-24-06 12 ENGINEERING SPECIFICATIONS                              ?[...]