Pentair PLDE48 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pentair PLDE48, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pentair PLDE48 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pentair PLDE48. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pentair PLDE48 should contain:
- informations concerning technical data of Pentair PLDE48
- name of the manufacturer and a year of construction of the Pentair PLDE48 item
- rules of operation, control and maintenance of the Pentair PLDE48 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pentair PLDE48 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pentair PLDE48, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pentair service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pentair PLDE48.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pentair PLDE48 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    System 2 TM Modular DE F ilter O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS MODELS PLDE36 PLDE48 Sta-Rite P ool/Spa Gr oup 293 Wright Street, Delavan, WI 53115 International: 262-728-5551, FAX: 262-728-7550 www.starite.com Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA © 2005, Sta-Rite Industries S749 ([...]

  • Page 2

    T able of Contents Safety Instructions .........................................................2 General Information ......................................................3 Specifications ...............................................................4 Installation ....................................................................5 Initial Start[...]

  • Page 3

    3 GENERAL INFORMA TION • Clean a new pool as well as possible before filling pool and operating filter . Excess dirt and large particles of foreign matter in the system can cause serious damage to the filter and pump. • W ith a modular Diatomaceous Earth (DE) filter in place and operating correctly , clean water is returned to the pool faster t[...]

  • Page 4

    4 Inlet Outlet 7-13/16 (198) 9-3/16 (233) 18.5 (470) 18.5 (470) 36 (914) 45.25 (1 150) 0 5 10 15 20 20 40 60 80 100 Pressure drop (PSI) Flow (GPM) PLDE36 PLDE48 SPECIFIC A TIONS FIGURE 1A – Dimensions in inches (mm) T able 1 - Recommended DE Manufacturers Johns Manville Celite 545™ GREFCO, Inc. Decalite 4200™ Eagle-Picher Minerals, Inc. Celat[...]

  • Page 5

    5 INST ALLA TION Installation of filter should only be done b y qualified, li- censed personnel. Filter Assembl y Filter mount must: • Be solid, level, rigid, vibration free, and provide for ad- equate drainage. • Be as close to pool as possible to reduce pressure loss from pipe friction. • Provide weather and freezing protection. • Provide[...]

  • Page 6

    6 valve, close the valve. NO TICE: Leaking around the Posi-Lok™ ring may indi- cate that the ring is not fully locked. In this case, pro- ceed as follows: a. Stop the pump, close the isolation valves, and open the air release valve to release any pressure within the filter . b. Remove the drain plug and drain all water from the filter . c. Push d[...]

  • Page 7

    7 5. Remove Posi-Lok™ ring as follows: a. Press safety latch (below the ring) toward the tank to release it (see Figure 4). b. Hold latch in the release position and rotate ring COUNTERCLOCKWISE to remove. If ring is difficult to turn, tap gently with a rubber mallet to overcome initial resistance. NO TICE: DO NOT use screwdriver or bladed instru[...]

  • Page 8

    MODULE CLEANING PRO- CEDURE Risk of chemical burns. Do not attempt to acid clean the filter or module. If the filter re- quires acid cleaning, have a trained pool professional do the job. Follow all steps in the “Disassembly” section of this manual. The filter module should be removed and cleaned when pressure rises more than 10 psi (69 kPa) ab[...]

  • Page 9

    9 SYSTEM INSPECTION Gener al: W ash the outside of the filter with a mild detergent and water . Rinse off with a hose. NO TICE: DO NOT use solvents to clean the filter; sol- vents may damage plastic components in the system. NO TICE: Open the air bleed valve and bleed all air from the filter each time the pump is stopped and restarted. W eekly Insp[...]

  • Page 10

    10 3 6 4 5 7 8 11 10 9 1 6 A 2 4 3 2 O P E N C L O S E PLDE 36 PLDE 48 12 Key Part No. Description Qty. PLDE36 PLDE48 1 Posi-Lok™ Ring 1 27001-0054S 27001-0054S 2 Air Release Valve with O-ring 1 25010-0200 24206-0103S 3 Presure Gauge 1 15060-000T 15060-000T 4 Tank Upper Half with Air Relief Valve 1 27001-0020S 27001-0030S 5 Tank O-Ring 1 27001-00[...]

  • Page 11

    11 1. Short Cycle T ime: NOTICE: Cycle Time will vary with each installation and be- tween different areas of the country. The following causes and remedies are for cycle times shorter than normal for your area. A. Chlorine residual too low; maintain proper residual (con- sult pool professional for recommendation). B. Flow rate too high; restrict f[...]

  • Page 12

    CREATE A RECORD OF YOUR WARRANTY AT STA-RITE: • Complete a warranty registration at www.staritepool.com by clicking on “Register Products” and selecting Sta-Rite Pool OR • Complete bottom portion completely and mail within 10 days of installation to Sta-Rite, Attn.: Pool Warranty Dept., 293 Wright St., Delavan , WI 53115 W arranty Registrat[...]

  • Page 13

    F iltr o modular de tierr a de diatomeas “System 2 TM” MANUAL DEL PROPIET ARIO INST ALACIÓN, OPERACIÓN Y REPUEST OS MODELOS PLDE36 PLDE48 Sta-Rite P ool/Spa Group 293 Wright Street, Delavan, WI 53115 Internacional: 262-728-5551, FAX: 262-728-7550 www.starite.com Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA © 2005, St[...]

  • Page 14

    Índice Instrucciones de seguridad ............................................2 Información general ......................................................3 Especificaciones ............................................................4 Instalación ....................................................................5 Arranque inicial .............[...]

  • Page 15

    3 INFORMA CIÓN GENERAL • Limpie una piscina nueva a fondo antes de llenarla y hacer funcionar el filtro. El exceso de suciedad y de partículas de materias extrañas grandes en el sistema puede provocar daños graves en el filtro y en la bomba. • Con un filtro modular de diatomeas (DE) instalado y funcio- nando debidamente, el agua limpia vuel[...]

  • Page 16

    4 Inlet Outlet 7-13/16 (198) 9-3/16 (233) 18.5 (470) 18.5 (470) 36 (914) 45.25 (1 150) 0 5 10 15 20 20 40 60 80 100 Pressure drop (PSI) Flow (GPM) PLDE36 PLDE48 ESPECIFIC ACIONES FIGURA 1A – Dimensiones en pulgadas (mm) Cuadro 1 - F abricantes de tierra de diatomeas recomendados Johns Manville Celite 545™ GREFCO, Inc. Decalite 4200™ Eagle-Pic[...]

  • Page 17

    5 INST ALA CIÓN La instalación del filtro debe ser realizada sólo por personas calificadas y competentes. Ensamblaje del filtro La instalación del filtro debe: • Ser firme, nivelada, rígida, sin vibraciones y con un drenaje adecuado. • Estar lo más cerca posible de la piscina para reducir la pér- dida de presión debido a la fricción de[...]

  • Page 18

    6 6. Cuando salga un chorro firme de agua de la válvula de desa- hogo de aire, cierre la válvula. AVISO: Fugas alrededor del aro Posi-Lok TM pueden indicar que el aro no está totalmente trabado. En este caso, proceda de la siguiente manera: a. Detenga la bomba, cierre las válvulas de aislamiento y abra la válvula de desahogo de aire para solta[...]

  • Page 19

    7 5. Saque el aro Posi-Lok TM de la siguiente manera: a. Oprima el pasador de seguridad (debajo del aro) hacia el tanque para aflojarlo (consulte la Figura 4). b. Mantenga el pasador en la posición soltada y gire el aro HACIA LA IZQUIERDA para sacarlo. Si es difícil hacer girar el aro, se deberá golpetear suavemente con un mar- tillo de caucho p[...]

  • Page 20

    PROCEDIMIENT O DE LIMPIEZA DEL MÓDULO Riesgo de quemaduras de índole química. NO trate de limpiar el filtro o el módulo con ácido. Si el filtro requiere limpieza con ácido, contrate a un profesional capacitado para piscinas para realizar ese trabajo. Siga todos los pasos indicados en la sección de “Desensamblaje” de este manual. Es neces[...]

  • Page 21

    9 INSPECCIÓN DEL SIS- TEMA Gener al: Lave el exterior del filtro con un detergente suave y agua. Enjuague a manguera. AVISO: NO use solventes para limpiar el filtro, ya que estos pueden dañar los componentes de plástico en el sistema. AVISO: Abra la válvula de purga de aire y descargue todo el aire del filtro cada vez que detenga y vuelva a enc[...]

  • Page 22

    10 3 6 4 5 7 8 11 10 9 1 6 A 2 4 3 2 O P E N C L O S E PLDE 36 PLDE 48 12 Clave No. Descripción Cant. PLDE36 PLDE48 1 Aro Posi-Lok TM 1 27001-0054S 27001-0054S 2 Válvula de desahogo de aire con aro tórico 1 25010-0200 24206-0103S 3 Manómetro 1 15060-000T 15060-000T 4 Mitad superior del tanque con válvula de desahogo de aire 1 27001-0020S 27001[...]

  • Page 23

    11 1. T iempo de ciclo corto: AVISO: El tiempo de ciclo varía con cada instalación y entre difer- entes áreas del país. Las siguientes causas y soluciones son para tiempos de ciclo inferiores a los normales para su área. A. Cloro residual demasiado bajo; mantenga el residuo adecuado (obtenga las recomendaciones de un profesional de piscinas). [...]

  • Page 24

    PARA CREAR UN REGISTRO DE SU GARANTÍA CON STA-RITE: • Llene un registro de garantía en www.staritepool.com pulsando en “Registro de Productos” y seleccionando Albercas Sta-Rite O • Llene la porción inferior y envíela por correo dentro de los 10 días de la instalación, a Sta-Rite, a la atención del Departa mento de Garantías de Pisci[...]