Philips CBT3384 manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Philips CBT3384, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Philips CBT3384 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Philips CBT3384. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Philips CBT3384 should contain:
- informations concerning technical data of Philips CBT3384
- name of the manufacturer and a year of construction of the Philips CBT3384 item
- rules of operation, control and maintenance of the Philips CBT3384 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Philips CBT3384 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Philips CBT3384, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Philips service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Philips CBT3384.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Philips CBT3384 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

      CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 INTEGRA TED CIRCUITS Product data Supersedes data of 2001 Mar 10 File under Integrated Circuits — ICL03[...]

  • Page 2

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2 2001 Dec 20 853-2187 27501 FEA TURES • 5 Ω switch connection between two ports • TTL compatible control input and output levels • See CBTS3384 for CBT3384 with Schottky diode undershoot protection • See CBTD3384 for CBT3384 with level shifting diodes[...]

  • Page 3

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 3 LOGIC SYMBOL 1A1 1A5 2A1 2A5 1B1 1B5 2B1 2B5 3 11 2 10 14 22 15 23 SA00555 13 1 2OE 1OE FUNCTION T ABLE INPUTS OUTPUTS 1OE 2OE 1A, 1B 2A, 2B L L 1A = 1B 2A= 2B L H 1A = 1B Z H L Z 2A = 2B H H Z Z H = High voltage level L = Low voltage level Z = Hig[...]

  • Page 4

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 4 DC ELECTRICAL CHARACTERISTICS LIMITS SYMBOL P ARAMETER TEST CONDITIONS T amb = –40 to +85 ° C UNIT Min Ty p 1 Max V IK Input clamp voltage V CC = 4.5 V ; I I = –18 mA — — –1.2 V I I Input leakage current V CC = 5.5 V; V I = GND or 5.5 V [...]

  • Page 5

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 5 AC W A VEFORMS V M = 1.5 V , V IN = GND to 3.0 V INPUT 1.5 V OUTPUT t PLH t PHL SA00028 1.5 V 1.5 V 1.5 V 3 V 0 V V OH V OL W aveform 1. Input (An) to Output (Yn) Propagation Delays Output Control (Low-level enabling ) 1.5 V t PZH t PHZ V OH V OL t[...]

  • Page 6

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 6 SO24: plastic small outline package; 24 leads; body width 7.5 mm SOT137-1[...]

  • Page 7

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 7 SSOP24: plastic shrink small outline package; 24 leads; body width 5.3 mm SOT340-1[...]

  • Page 8

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 8 SSOP24: plastic shrink small outline package; 24 leads; body width 3.9 mm; lead pitch 0.635 mm SOT556-1[...]

  • Page 9

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 9 TSSOP24: plastic thin shrink small outline package; 24 leads; body width 4.4 mm SOT355-1[...]

  • Page 10

    Philips Semiconductors Product data CBT3384 10-bit bus switch with 5-bit output enables 2001 Dec 20 10 Definitions Short-form specification — The data in a short-form specification is extracted from a full data sheet with the same type number and title. For detailed information see the relevant data sheet or data handbook. Limiting values definit[...]