Go to page of
Similar user manuals
-
Portable Generator
Porter-Cable BSI525
20 pages 0.28 mb -
Portable Generator
Porter-Cable D29833-038-0
68 pages 2.18 mb -
Portable Generator
Porter-Cable H451CS
20 pages 0.27 mb -
Portable Generator
Porter-Cable CH250
20 pages 0.26 mb -
Portable Generator
Porter-Cable A02871-043-0
24 pages 1.69 mb -
Portable Generator
Porter-Cable BSV750
24 pages 0.8 mb -
Portable Generator
Porter-Cable H450IS
24 pages 0.49 mb -
Portable Generator
Porter-Cable D26779-028-0
20 pages 0.26 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Porter-Cable CH350CS, H650CS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Porter-Cable CH350CS, H650CS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Porter-Cable CH350CS, H650CS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Porter-Cable CH350CS, H650CS should contain:
- informations concerning technical data of Porter-Cable CH350CS, H650CS
- name of the manufacturer and a year of construction of the Porter-Cable CH350CS, H650CS item
- rules of operation, control and maintenance of the Porter-Cable CH350CS, H650CS item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Porter-Cable CH350CS, H650CS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Porter-Cable CH350CS, H650CS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Porter-Cable service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Porter-Cable CH350CS, H650CS.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Porter-Cable CH350CS, H650CS item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Part No. D21269-007-0 Generators Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. T ype Serial No. ESP AÑOL: PÁGINA 21 FRANÇAISE: P AGE 41 IMPORT ANT [...]
-
Page 2
2 — ENG This product is not equipped with a spark arresting muf fler . If the pr oduct will be used around flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required in the state of California. It is a vi[...]
-
Page 3
3 — ENG WARRANTY Porter-Cable Corporation 4825 Highway 45 North P .O. Box 2468 Jackson, TN 38302-2468 1-888-559-8550 PORTER-CABLE CORPORA TION warrants to the original pur chaser that each new electric generator and service part is free from defects in material and workmanship, and agrees to repair or replace under this warranty any defec- tive p[...]
-
Page 4
4 — ENG Attempting to connect generator directly to the electrical system of any building structure. Back feeding electricity through a building’ s electrical system to the outside utility feed lines could en- danger repair persons attempting to restore service. Attempting to connect to the incoming utility service could result in electrocu- ti[...]
-
Page 5
5 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. Use of worn, damaged, undersized or ungrounded extension cords. Placing generator on or against highly conductive surface, such as a steel walkway or metal roof. Improper connection of items to generator . Operation of unit when damaged, or with guards or panels[...]
-
Page 6
6 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF FIRE T ur n engine of f and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extin- guisher certified to handle gasoline or fuel fires. Add fuel to tank in well ventilated area. Make sure there are no sources of igniti[...]
-
Page 7
7 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF BREA THING - INHALA TION HAZARD Operate generator in clean, dry , well ventilated area. Never operate unit in enclosed areas such as garages, basements, storage, sheds, or in any location occupied by humans or ani- mals. Keep children, pets and oth- ers [...]
-
Page 8
8 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. • Review and understand all of t he operating instructions and warnings in this manual. • Become familiar with the operation and controls of the generator . Know how to shut it off quickly . • Equip area of operation with a fire extinguisher certified to h[...]
-
Page 9
9 — ENG RISK FROM LIFTING HAZARD HOW TO PREVENT IT WHA T COULD HAPPEN The generator is too heavy to be lifted by one person. Obtain assistance from others before you try to move it. Serious injury can result from attempt- ing to lift too heavy an object. Lifting a very heavy object. READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA T[...]
-
Page 10
10 — ENG Extension Cord Wire Gauge Chart Amperage *Up to 20 amp draw Up to 30 amp draw Cord Length 0 to 100 ft. 0 to 100 ft. Wire Gauge Size 12 ga. 10 ga. *NOTE: When amperage exceeds 20 amps; a 12 gauge extension cord should not be used for long distances. Extension Cords When using an appliance or tool at a considerable distance from the genera[...]
-
Page 11
11 — ENG OPERA TION KNOW YOUR GENERA TOR Read this General Manual and Safety Rules before operation of your Generator . Compare the illustration in your parts manual with your generator to familiarize yourself with the location and use of various controls. Save all manuals for future references. IMPORT ANT : Exceeding the rated capacity of your g[...]
-
Page 12
12 — ENG 2. Check fuel level and fill as required. Make sure generator is turned off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline. Never fill fuel tank completely . Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel e[...]
-
Page 13
13 — ENG TO ST AR T THE ENGINE Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas. 1. Open the fuel shut-off valve on tank and engine. 2. Move the choke control located on the engine to "CHOKE" position. NOTE: No choke is required on warm engines. Make sure[...]
-
Page 14
14 — ENG MAINTENANCE Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter , mor e often if operated in extreme dusty or dirty conditions. Note 2: Check oil after 5 hours of operation CUSTOMER RESPONSIBILITIES T ABLE MAINTENANCE T ASK Before each use X Every 25 Hours or Every Season See Note 2 X Every 50 H[...]
-
Page 15
15 — ENG STORAGE If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage. Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach an open flame, spark or pilot light as on a fur nace, water heater , clot[...]
-
Page 16
16 — ENG Never exceed the rated capacity of your generator . Serious damage to the generator or appliance could result from an overload. 1. S tarting and running wattage requirements should always be calculated when matching a generators wattage capacity to the appliance or tool. 2. There are two types of electrical appliances that can be powered[...]
-
Page 17
17 — ENG ST AR TING W A TT AGE REQUIREMENTS 1. Some appliances and tools will list on the motor name plate the starting and running voltage and amperage requirements. Use the following formula to convert voltage and amperage to wattage: V olts X Amp = W atts 120 volts x 10 amps = 1200 watts 2 . T o determine the approximate starting wattage requi[...]
-
Page 18
18 — ENG HOUSEHOLD W A TT AGE CALCULA TOR W A TT AGE CALCULA TIONS APPLIANCE OR LOAD DEVICE* REFRIGERA TOR/ FREEZER 800 SMALL REFRIGERA TOR AIR COND.(ROOM) SUMP PUMP 1/2 HP 600 TELEVISION CAUTION !! HOT PLA TE MICROWA VE SP ACE HEA TER 2400 1000 3 2 LIGHTING 60 WA TT BULBS 75 WA TT BULBS 100 WA TT BULBS 300 WA TT BULBS ELECTRIC LOAD GRAND TOT AL [...]
-
Page 19
19 — ENG TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine will not start No electrical output Repeated circuit breaker tripping Generator overheating No auto idle DC does not have power with the circuit breaker depressed 1. Low on fuel or oil. 2. Ignition switch in "Off" position. 3. Faulty spark plug. 4. Choke in wrong position. 5[...]
-
Page 20
20 — ENG EN G IN E GA S WA T T AGE WIRI NG EN GI N E Allow the g e nerato r to ru n 5 minutes at no load f o r the eng ine a nd the g enhea d to s ta b iliz e. OP ERA T I ON M ake su r e t h e ade qu a t e siz e o f e xt e n sio n co r d i s u s e d. Re fe r t o t h e G r o u n din g Ins truc ti ons /E x t e ns i on Cord s e ct i on of the o w ne[...]