Go to page of
Similar user manuals
-
Power Supply
Powerware 9390
206 pages 3.25 mb -
Power Supply
Powerware 9
70 pages 0.91 mb -
Power Supply
Powerware 3110
18 pages 0.21 mb -
Power Supply
Powerware UPS20-30kVA
52 pages 0.53 mb -
Power Supply
Powerware P93
6 pages 0.16 mb -
Power Supply
Powerware Powerware 9395 UPS 10001100 kVA
174 pages 2.59 mb -
Power Supply
Powerware 5000
66 pages 1.12 mb -
Power Supply
Powerware Powerware 9395 UPS and Plus 1 UPS 650825 kVA
192 pages 2.77 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Powerware 3115, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Powerware 3115 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Powerware 3115. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Powerware 3115 should contain:
- informations concerning technical data of Powerware 3115
- name of the manufacturer and a year of construction of the Powerware 3115 item
- rules of operation, control and maintenance of the Powerware 3115 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Powerware 3115 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Powerware 3115, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Powerware service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Powerware 3115.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Powerware 3115 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Power w are ® 3115 User ’s Guide 30 0-650 V A www . powerware.com 02/15/01[...]
-
Page 2
Po werwar e is a r egist er ed tr ademark of Po werwar e Corpo rat ion . Cop yright 1999 Powerwa r e C orporation, Raleig h, N C. All rights r ese rved. No part of this document may be reproduced in an y way wit hou t the expr ess wri tt en appr oval of Po werwar e Corpo rat ion .[...]
-
Page 3
Class B Statement for FCC and ICES NOTE Th is equ ipmen t has been t ested and fou nd to co mply wi th t he limit s for a Class B devi ce pursu ant to P art 15 of FCC R ules. Thes e limits ar e de signed to provide reas onable protection aga inst ha rmful interferenc e when this equipme nt is oper ated i n a r esiden tial env ir onmen t. T his equ [...]
-
Page 4
Special Symbols The follow ing ar e exam ples of sym bols us ed on t he UPS to alert you to import ant inf ormation: Risk of Electr ic Shock Do Not Open Cover C C C CA A A AU U U UT T T TI I I IO O O ON N N N CAU TIO N T o reduce the r isk of el ectr ic shock, Do not remove cover (or back) No user -serv iceabl e parts insi de Re fer servicing to th[...]
-
Page 5
i Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T ABLE OF C ONTENTS 1 Powerwar e 3115 – One of the Best! 1 .................................. 2 Installation 3 ..................................................... Ins pecti ng the Equipment 3 ....................................................... Safety Precauti ons 3 .................[...]
-
Page 6
T a ble of Conten ts ii Powerw are ® 3115 U ser’s Gui de www .powerw are.c om[...]
-
Page 7
1 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 1 P OWERWARE 3115 – ONE OF THE BEST! The P owerware 3115 un interr uptibl e power sys tem (UPS) protects your sensitive e lect r o nic equipme nt fr o m three basic p owe r p r o blems: power fai lur es, power s ags , and power s ur ges. Po wer ou tages can occu r when y ou least[...]
-
Page 8
Pow erw ar e 3115 – ONE OF T HE BEST ! 2 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om 650 VA 300 VA and 420 VA Figure 1. Powerware 3115[...]
-
Page 9
3 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 2 I NST ALLA TION This se ction e xpla ins: Equ ipment i nspecti on Safet y pr ecaut ion s UPS in stallation UP S r ear panel s Inspecting the Equipment If a ny equip ment ha s bee n dam age d during ship ment , k ee p the ship ping cart ons an d packi ng mat eri als fo r the carr [...]
-
Page 10
In stallat ion 4 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om WAR NING This UPS contai ns its own energy s ource (batteri es). The output rec eptacl es may carry live vol tage even when the U PS is not c onnected to an AC suppl y . Do not rem ove or unplug the i nput cord when the UPS is turned on. Thi s removes the safety ground from t[...]
-
Page 11
In stallat ion 5 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om 5. Sta rt the U PS by pres sing the button as shown i n Figu re 2. The Powe r On ind icat or illumina tes i ndica ting tha t po wer is avai labl e fr om th e rear r eceptacles . On/O ff Button Power O n Indicator T est/A larm R eset Button Figure 2. Powerware 3115 Front Panel[...]
-
Page 12
In stallat ion 6 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om UPS Rear Panels Thi s section sh ows the r ear panels of all Power ware 3115 models. Power C ord with 5-15 Plug Com munication Port DIP S witches T w o 5 - 15 Output Receptacl es 10A, R esettable Ci rcuit Breaker Si te Wiring Fault Indicator Figure 3. PW3 300 and PW 3 42 0 R [...]
-
Page 13
In stallat ion 7 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om 10A, IEC-320 I nput Connector with Fuse Com munication Port DIP S witches T w o IEC- 320 Output Receptacl es Figure 5. PW 3 300i and PW3 420i Rear Panel Com munication Port 10A, I EC-320, Input C onnector with Fuse DIP S witches Four IEC- 320 Output Receptacl es Figure 6. PW3[...]
-
Page 14
In stallat ion 8 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om[...]
-
Page 15
9 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 3 O PERA TION AND C ONFIGURA TION Th is sect ion cov ers: T urning t he UPS o n and off Starting th e UPS on batte ry Standby mode How to set DIP switch es Conf iguring the c omm unicat ion po rt T urning the UPS O n T o tur n on the UPS, pr ess the button on th e fr ont pa n el (s[...]
-
Page 16
Operat ion and C onfigura tion 10 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Standby Mode When the UPS is turne d off and p lugged int o a wall outle t or othe r power s our ce, the UP S is in S tan dby mode. Th e batt ery r echar ges wh en neces sary an d the Pow er On in dicat or is of f, i ndi catin g that power i s not avai labl e[...]
-
Page 17
Operat ion and C onfigura tion 11 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T able 1. DIP S witch Se ttings 120V M odels D I PS w i t c h1 D I PS w i t c h2 D I PS w i t c h3 D I PS w i t c h4 Output Vol tage 110V ON OFF p g 120V* OFF OFF 127V OFF ON Utility Power 103V - 142V* OFF OF F y Range 98V - 142V ON ON 93V - 142V OFF ON 88V -[...]
-
Page 18
Operat ion and C onfigura tion 12 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Wh en the commu ni cation cabl e is in stal led, power m anag ement sof twar e can exch ange dat a wit h th e UPS . Th e soft war e polls th e UPS for detailed infor mation on the statu s of th e p ower envir onment. If a power emer gen cy occu rs, the s oftw[...]
-
Page 19
13 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 4 UPS M AINTENANCE This sec tion ex plains how t o: Ca r e f or the UPS and ba tte ries Replace the batte r ies T e s t new batte r ies Recycl e used bat teri es UPS and Ba ttery Care Fo r th e best pr even tiv e main tenan ce, keep t he ar ea ar oun d th e UPS clean and du st-fr [...]
-
Page 20
UPS Mai ntenance 14 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Replacing Batteries Th e fol low in g st eps expl ain h ow to r eplace th e batter ies. Con sider all warn ing s, cauti ons, an d notes bef or e r eplaci ng batt eri es. WAR NING Batteries c an present a ris k of elec trical s hock or burn from high s hort circ uit current[...]
-
Page 21
UPS Mai ntenance 15 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Bla ck ( –) Red (+ ) Figure 9. Replacing Batteries (300 V A and 420 V A models)[...]
-
Page 22
UPS Mai ntenance 16 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Bla ck ( –) Red (+ ) Figure 10. Replacing Batteries (650 V A models)[...]
-
Page 23
UPS Mai ntenance 17 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T esting New Batteries NOTE It i s recom mended that the UPS charge for 24 hours before tes ting the new batteries . Press and ho ld the button for th ree seconds to initi ate the battery test. Th e UPS au tomatically distr ibutes s ome of the load to th e batteries for 1 [...]
-
Page 24
UPS Mai ntenance 18 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om[...]
-
Page 25
19 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 5 S PECIFICA TIONS Th is s ection pr ovi des th e foll owin g specif icati ons fo r th e Powerwar e 3115 models: El ectri cal inpu t and outpu t Battery W e ights a nd dim ensions Environm enta l and sa fet y T able 3. Model List 120V M odels 230V M odels UPS Models PW3 300 PW3 42[...]
-
Page 26
Sp ecification s 20 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T abl e 5. Electrical O utput 120V M odels 230V M odels Power L evel s (r ated at nomi nal input s) PW3 300: 300 VA , 180W PW3 420: 420 VA , 252W PW3 650: 650 VA , 400W PW3 300i: 300 VA , 180W PW3 420i: 420 VA , 252W PW3 650i: 650 VA , 400W Regulat ion Onli ne Less than 1%[...]
-
Page 27
Sp ecification s 21 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T abl e 7. W eight s and Dimensions 120V M odels 230V M odels UPS Dimens ions (HxW xD) PW3 300: 155 x 86 x 371 mm (6.1 x 3.4 x 14.6 in ) PW3 420: 155 x 86 x 371 mm (6.1 x 3.4 x 14.6 in ) PW3 650: 163 x 117 x 356 mm (6.4 x 4.6 x 14.0 in ) PW3 300i: 155 x 86 x 371 mm (6.1 x [...]
-
Page 28
Sp ecification s 22 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om[...]
-
Page 29
23 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 6 T ROUBLESHOOTING This se ction e xpla ins: Site wir ing fault on 120V mode l s UPS a larms a nd cond itions How to silenc e a n alarm Servic e and supp ort Site Wiring Fault (120V Models only) The Site Wiring Fault indic ator on the rear pa nel of the UPS illuminat es if the gro[...]
-
Page 30
T r oubles hooting 24 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T abl e 9. T roubl eshooting Alar m or Condit ion Pos si ble Cause Acti on The Power O n indicator is not on; the U PS does not The line cord i s not connected or not plugged in. Connect the line cord to the U PS and plug the U PS into a working outl et. start. The wall [...]
-
Page 31
T r oubles hooting 25 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Acti on Poss ible Caus e Alar m or Condit ion The UPS beeps 1 tim e every 0.5 second. Power requirem ents exceed UPS capacity (overload is greater than 120%) or the l oad is defective. Rem ove some of the equipm ent from the U PS. You may need to obtain a l arger capacit[...]
-
Page 32
T r oubles hooting 26 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om[...]