A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Premier Mounts PP-FCTA-QL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Premier Mounts PP-FCTA-QL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Premier Mounts PP-FCTA-QL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Premier Mounts PP-FCTA-QL should contain:
- informations concerning technical data of Premier Mounts PP-FCTA-QL
- name of the manufacturer and a year of construction of the Premier Mounts PP-FCTA-QL item
- rules of operation, control and maintenance of the Premier Mounts PP-FCTA-QL item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Premier Mounts PP-FCTA-QL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Premier Mounts PP-FCTA-QL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Premier Mounts service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Premier Mounts PP-FCTA-QL.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Premier Mounts PP-FCTA-QL item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTALLATION INSTRUCTIONS PP-FCTA-QL Ceiling Adapter NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada – Phone: 800-368-9700 Fax: 800-832-4888 EUROPE Swallow House, Shilton Industrial Estate, Shilton, Coventry, England CV79JY Phone: +44 (0) 2476 614700 Fax: +44 (0) 2476 614710 Other Locations – Phone: (001)-714-632-71[...]

  • Page 2

    Page 2 Installation Instructions PP-FCTA-QL Table of Contents W arning Statements W arning Statements 2 Parts List 3 Installation T ools 3 Plate Assembly 4 Securing the Plate 5 Electrical Box Installation 5 Ceiling Anchoring 7 Cable Lock Operation 8 Securing Pipe to PP-FCT A-QL 10 T echnical Speci fi cations 10 W arranty 1 1 Contact Premier Mounts[...]

  • Page 3

    Installation Instructions Page 3 Parts List This ceiling adapter comes packaged with installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700). Ceiling Adapter (Qt[...]

  • Page 4

    Page 4 Installation Instructions Plate Assembly Step 1. Assemble the plate. Step 2. Place the lower adapter plate with the threaded studs on it up through mounting plate. Step 3. The threaded studs will align with the adjustable slide on the mount. Step 4. Once the two pieces are together, align the mounting holes on the upper adapter plate with th[...]

  • Page 5

    Installation Instructions Page 5 PP-FCTA-QL Securing the Plate Adjust and Tighten Wing Nut M5 x 16mm Set Screw Tiles T-Bar Frame Rails Step 1. Position and slide the adapter plate to the hole and secure the ceiling plate to the rails by tightening the four (4) M5 x 16m m Phillips head screws. Step 2. Center the stud plate to the hole and secure the[...]

  • Page 6

    Page 6 Installation Instructions The electrical cut-outs allow for both single and square electrical box installations. PP-FCTA-QL Electrical Box[...]

  • Page 7

    Installation Instructions Page 7 PP-FCTA-QL Ceiling Anchoring T russ Concr ete W ood T russ ceiling Step 1. Loop the braided cable around the truss. Step 2. Run the open end through the loop. Step 3. Pull the open end down until the braided cable tightens around the truss. W ood joist Step 1. Secure the four (4) ¼” eye lag screws to the wood joi[...]

  • Page 8

    Page 8 Installation Instructions PP-FCTA-QL Release Pin Release Pin Release Pin Release Pin 6” Excess Braided Cable Braided Cable Braided Cable Braided Cable Mounting Hole Mounting Hole Mounting Hole Directional Input Arrows Directional Input Arrows Directional Input Arrows Cable Output Cable Input Directional Input Arrows Release Pin Directional[...]

  • Page 9

    Installation Instructions Page 9 Braided Cable T-Bar Frame Ceiling Tile Quick Lock PP-FCTA-QL Step 1. Thread each braided cable through the Quick Lock, the mounting hole in the corner of ceiling mount, and then completely through the opposite side of the Quick Lock to secure. Step 2. Adjust the braided cable tension. but do not overtighten. Step 3.[...]

  • Page 10

    Page 10 Installation Instructions PP-FCTA-QL T echnical Speci fi cations All measurements are in inches [mm]. Securing Pipe to the PP-FCTA-QL Step 1. Secure the 1½” (NPT) pipe to the ceiling plate and tighten by using one (1) M5 x 16 Phillips head screw (supplied) to the plate. 1-1/2” Pipe M5 x 16mm Set Screw 1-1/2” Pipe Ceiling Plate Assem[...]

  • Page 11

    W arranty PREMIER MOUNTS LIMITED LIFETIME W ARRANTY What and Who is Cover ed by this Limited W arranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Pr[...]