The rules should oblige the seller to give the purchaser an operating instrucion of Premier Fire Alarm Control Panel, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Premier Fire Alarm Control Panel one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Premier Fire Alarm Control Panel. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Premier Fire Alarm Control Panel should contain:
- informations concerning technical data of Premier Fire Alarm Control Panel
- name of the manufacturer and a year of construction of the Premier Fire Alarm Control Panel item
- rules of operation, control and maintenance of the Premier Fire Alarm Control Panel item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Premier Fire Alarm Control Panel alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Premier Fire Alarm Control Panel, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Premier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Premier Fire Alarm Control Panel.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Premier Fire Alarm Control Panel item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    . USER MANUAL , MAINTENANCE GUIDE & LOG BOOK[...]

  • Page 2

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 2 Issue: 1.3 Authorised: GH Date: 9/6/2004 CONTENTS 1. FIRE ALARM CONTROL PANEL SA FETY ISSUES……………………………………… 3 How to use this Fire Alarm Panel safely 2. THE PURPOSE OF A FIRE ALA RM SYSTEM……………………………?[...]

  • Page 3

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 3 Issue: 1.3 Authorised: GH Date: 9/6/2004 1. FIRE ALARM CONTROL PANEL SAFETY ISSUES There is no need to open this fire alarm duri ng normal oper ation. Any work carried out on this system must be performed by a competent person who is familiar with this[...]

  • Page 4

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 4 Issue: 1.3 Authorised: GH Date: 9/6/2004 3. USER RESPONSIBILITIES & MAIN TAINENCE OF THE FIRE ALARM SYSTEM, INCLUDING THE FACP & ITS INTEGRAL PSE According to the British Standard Code for F ire De tection and Alarm S ystems for Commercial Buil[...]

  • Page 5

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 5 Issue: 1.3 Authorised: GH Date: 9/6/2004 4. PANEL INDICATIONS & CONTROLS POWER GEN-FIRE GEN-F AUL T SUPPL Y FL T SYST EM FLT GE N-S/C DEL GEN- ZONE T EST GEN-DISABLEMENT 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 FIRE / ZO NES ZONAL F AUL T / DISABL EMENT / T[...]

  • Page 6

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 6 Issue: 1.3 Authorised: GH Date: 9/6/2004 4.3 SUMMARY OF LED COMBINATIONS AND THEIR MEA NING Use the table below to determine the conditio n of the pan el. LEDs LIT LED CONDITION PANEL STATUS POWER C O N S T A N T G R E E N The panel is supplied with po[...]

  • Page 7

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 7 Issue: 1.3 Authorised: GH Date: 9/6/2004 5. THE FIRE CONDITION 5.1 HOW THE PREMIER SX INDICATES AN ALARM POWER GEN- FIR E GEN -FAULT SUPPL Y F LT SYSTEM F LT GEN -S/C DEL GEN- ZO NE TES T GEN-DISABLEMENT 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 FI RE / ZO NES Z[...]

  • Page 8

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 8 Issue: 1.3 Authorised: GH Date: 9/6/2004 6. THE FAULT CONDITION 6.1 DIFFERENT TYPES OF FA ULT The fire alarm monitors itself, and any equip ment connected to i t, for any faults that can occur. If a fault occurs, the Panel responds by activating its In[...]

  • Page 9

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 9 Issue: 1.3 Authorised: GH Date: 9/6/2004 6.2 WHAT TO DO IF A FA ULT CONDITION OCCURS If a fault occurs, the responsible person should: • Turn keyswitch to Controls enabled and pres s silence flt tone button (button 2) to silence the fault buzzer . ?[...]

  • Page 10

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 10 Issue: 1.3 Authorised: GH Date: 9/6/2004 7. DISABLEMENTS 7.1 REASONS FOR DISABLING CERTAIN PARTS OF A FIRE A LARM SYSTEM. Certain parts of this Fire Alarm Panel can be temporaril y disabl ed (i.e. switched off) to suit prevailin g conditions. For exam[...]

  • Page 11

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 11 Issue: 1.3 Authorised: GH Date: 9/6/2004 8. USING SOUNDER DELAYS 8.1 WHAT IS A SOUNDER DELAY In certain circumstances it m ay be desir able to hav e a delay bet w een the pan el detecting a fire, an d starting its external sounders, to allow the respo[...]

  • Page 12

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 12 Issue: 1.3 Authorised: GH Date: 9/6/2004 9. SYSTEM DESCRIPTION FIRE ALARM SYSTEM SUMMARY: FIRE ZONE INFORMATION ZONE NUMBER ZONE DESCRIPTION A brief description of all the rooms and areas contained in each zone QTY SNDR QTY MCP QTY HEADS 1 2 3 4 5 6 7[...]

  • Page 13

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 13 Issue: 1.3 Authorised: GH Date: 9/6/2004 10. FIRE ALARM LOG BOOK It is recommended that this L OG BOOK section of the Manual be maintaine d by the responsible person(s) on site, who should ensure every event is properly recorded (i ncluding fire alarm[...]

  • Page 14

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 14 Issue: 1.3 Authorised: GH Date: 9/6/2004 MAINTENANCE WORK DATE TIME ZONE / LOCATION REASON FOR WORK WORK CARRIED OUT ADDITIONAL WORK REQUIRED SIGNED[...]

  • Page 15

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 15 Issue: 1.3 Authorised: GH Date: 9/6/2004 FALSE ALARMS DATE TIME ZONE / LOCATION CAUSE (IF KNOWN) OR ACTIVITIES IN ALARM AREA MAINTENANCE VISIT NEEDED (YES/NO) MAINTENANCE FINDINGS CATEGORY OF FALSE ALARM FURTHER ACTION REQUIRED SIGNED[...]

  • Page 16

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 16 Issue: 1.3 Authorised: GH Date: 9/6/2004 ALL EVENTS OTHER THAN MAINTE NANCE WORK OR FALSE ALARMS DATE TIME ZONE / LOCATION DETAILS OF EVENT (INCLUDING CAUSE IF KNOWN) ACTION REQUIRED DATE COMPLETED INITIALS[...]

  • Page 17

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 17 Issue: 1.3 Authorised: GH Date: 9/6/2004 11 COMMISSIONING THE SYSTE M, INCLUDING P.S.E. • The commissioning of this fire alarm system should b e performed b y a qual ified commissioning engin eer, who h as an understanding of sections 2, 3,& 4 o[...]

  • Page 18

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 18 Issue: 1.3 Authorised: GH Date: 9/6/2004 I/we bein g the co mpetent person(s) res ponsible (a s indicated by my/our signatures below) for the design of the f ire alarm s ystem, particul ars of which are set out below , CER T IFY that the said design f[...]

  • Page 19

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 19 Issue: 1.3 Authorised: GH Date: 9/6/2004 The System is manual. T ype & siting of manual c all points takes account of the guidelines co ntained in sect ion 3 of B S 5839- 1 The syst em in cor porate s au tom ati c fir e detec tors , and acco unt h[...]

  • Page 20

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 20 Issue: 1.3 Authorised: GH Date: 9/6/2004 I/we be ing t he competent per son(s) r esponsibl e (as indic ated by my/ our s ignatu res bel ow) fo r the insta llat ion of the fire alarm system, partic ula rs of which are set out below , CER T IFY that the[...]

  • Page 21

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 21 Issue: 1.3 Authorised: GH Date: 9/6/2004 I/we being the competent person(s) re sponsible (as indicated by my/our signatures below) for the commissioning of the fire alarm syste m, particulars of which are set out below , CER T IFY tha t the said work [...]

  • Page 22

    PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-102 PAGE 22 Issue: 1.3 Authorised: GH Date: 9/6/2004 I/we being the competent person(s) responsible (as indicated by my/our signatures below) for the acceptance of the f ire alarm system, pa rticulars of which are set out be low , AC CEPT t he system on behalf of[...]