Go to page of
Similar user manuals
-
Carbon Monoxide Alarm
Princeton Digital (USA) SP-2300i
25 pages 0.85 mb -
Universal Remote
Princeton Digital (USA) 4411-0062
116 pages 2.02 mb -
Flat Panel Television
Princeton Digital (USA) TLA-04641C
64 pages 5.55 mb -
Computer Monitor
Princeton Digital (USA) VL2018W
13 pages 0.52 mb -
Music Pedal
Princeton Digital (USA) G9.2tt2q
51 pages 4.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Princeton Digital (USA) SP-2300i, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Princeton Digital (USA) SP-2300i one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Princeton Digital (USA) SP-2300i. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Princeton Digital (USA) SP-2300i should contain:
- informations concerning technical data of Princeton Digital (USA) SP-2300i
- name of the manufacturer and a year of construction of the Princeton Digital (USA) SP-2300i item
- rules of operation, control and maintenance of the Princeton Digital (USA) SP-2300i item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Princeton Digital (USA) SP-2300i alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Princeton Digital (USA) SP-2300i, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Princeton Digital (USA) service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Princeton Digital (USA) SP-2300i.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Princeton Digital (USA) SP-2300i item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3 584, Fax: (978)263-50 86 Web Site: www.princetoninstruments.com Operating Instructions A cton Se ries SP - 2300i 0.300 Meter Focal Length Triple Grating Imaging Monochromator / Spectrograph Rev 4 .0 9. 23[...]
-
Page 2
1 A cton SP-2300i Operating Inst ructions CONTENTS: Page I. Brief Introduction and SP- 2300i Description 2 II. Specifications 3 III. SP - 2300i Setup 4 A. Unpacking Note 4 B. Connecting the SP -2300i to a Computer 4 C. Cables and Connecti ons for SP-2300i 5 D. Mounting Accessories 6 E. Mounting Focal Plane Detectors 7 F. Slit Width Adjustment in th[...]
-
Page 3
2 I : Brief Introductio n and SP-2300i Descr iption Brief Introduction: This instruction manual is i ntended to assist you in s et - up and operation of your new SP -2300i monochromator/spectrograp h. Even if you are an experienc ed user of spectrosc opic equipment, we suggest that you follow the manual (at leas t initially) to insure proper setup [...]
-
Page 4
3 II : SP -2300i Specifications Every SP-2 300i monochromator or spec trograph includes a triple grating turret for 1, 2, or 3 gratings, 32 -bit microprocessor controll ed scanning, buil t-in RS - 232 and USB interfaces, and micrometer controlled e ntrance slit. Specifications (1200g/mm Grating) Focal Length: 300 mm Aperture Ratio: f/4 Optical Desi[...]
-
Page 5
4 III : SP -2300i Setup Section III-A: Unpacking and Inspection Carefully unpack and examine the SP-2300i and any ac cessories purc hased. Note: Report any damage i mmediately t o the carrier and t o Princeton Instrum ents, and save all pac ki ng materia l. Setup: Position the monochromator where it wi ll be used and remove all pack ing materials i[...]
-
Page 6
5 Section III-C: Cables and Connections for SP-2300i The following computer cables are supplied wi th the SP-2300i: CC - 499 - 2 IBM AT or compatible 9 pin female ( DB9S) connector to 9 pin male connector (DB9P). 3650 -USB- 06 USB Cable Type A to Type B. If neither of thes e cables is compatible with your system, consul t Princeton Instruments for [...]
-
Page 7
6 Section III-D: Mounting Accessories to the SP -2300i Slit A sse mblies All Acton accessories come with thei r own set of instructions for proper mounting and operation. The instructions below are only general i nformation. Pleas e refer to the individual instructions for detailed information. Accessories: The full range of Acton monochromator/spe[...]
-
Page 8
7 Section III-E: Detector Mounting Instructions: Mounting Focal Plane Detectors to the SP-2300i Spectrograph The standard mounting f lange for CCDs and diode arrays acc ommodates detectors with two diff erent bolt circles. There are three (3) equal ly spaced #10 - 32 tapped holes on a 3.60” bolt circle, and three (3) equally spaced holes on a 3.8[...]
-
Page 9
8 Section III-F: Slit Width A djustments in the Model 716 Bilateral Slits The slit width of eac h bilateral slit assembly (716 type) is adjustable f rom 0.010 millimeters to 3 millimeters (10 to 3,000 µm) by a micrometer knob loc ated on the top of the sl it housing. The micrometer knob is graduated i n 0.010 millimeter (10 µm) increments. Each c[...]
-
Page 10
9 IV : SP-2300 i Operation Section IV-A: Initialization W hen power is turned ON to the SP -2300i, it ini tializes to a wavelength of 0.0 nm for grating number 1. If the power is switched OFF and then ON again to the SP-230 0i, it will re-ini tialize. Initialization gives the s ystem a reference, or starting pos ition to keep track of wavelength po[...]
-
Page 11
10 NM/MIN Sets the scan rate i n nm/min to 0.01 nm/min resolution with units nm/min ?NM/MIN Returns present scan rate i n nm/min to 0.01 nm/min resoluti on with units nm/min Grating Contro l Commands : GRAT ING Places specified grating in position to the wavelength of the wavelength on the present grating. Up to nine (9) gratings are allowed on thr[...]
-
Page 12
11 Slit Width Cont rol Command s (for Motorized Slits only ): FRONT-EX IT-SLIT Designates front ex it slit to receive slit control commands. Note : The designation remains in effec t until changed by another slit des ignator. This command does not have to be repeated unti l the designate d sl it is changed. SIDE-EXIT-SLIT Designates side exi t slit[...]
-
Page 13
12 Section IV-C : Focusing and A lignment of A rra y Detectors W ith the array detector properly mounted to the SP-2300 i, use the followi ng procedure to align and foc us the array detector to the SP-230 0i optical system. It is as sumed that the array detection s ystem is running with SpectraSense or W inSpec. 1. M ount a light s ource such as a [...]
-
Page 14
13 Section IV-D : Conv erting the SP-2300i from Monochromator to Spectrograph, or Spectrograph to Monochromator Monochromator to Sp ectrograph: This procedure requires that you ha ve the monochromator version, Model SP- 2355 or SP- 2357 , plus the array detector mounting fl an ge. May require a spac er. 1. Using a 1/8” All en wrench, loosen the t[...]
-
Page 15
14 V : Ap pendices and Schemat ic Dra wings A ppendix V -A: Selecting Alternate Start-Up Para meters The following are the Start-U p parameters and their def ault values: GRATING #1 WAVELENGTH 0.0 nm SCAN SPEED 100.0 nm/min Each of the above may be changed through the RS - 232 port or USB port using the f ollowing commands. These values are stored [...]
-
Page 16
15 A ppendix V-B: Cable Connection Diagrams - Monochromators & Spectrographs to Computer Figure 9 . RS -232 Cable Wir ing Figure 10 . Cable Connections (Back Panel ) POWER Power connection +5 and +24 Vol ts USB HUB USB Hub 1.1 compatible. USB USB connection to computer. RS - 232 RS -232 connection to c omputer. READY Ready light is on whe n the[...]
-
Page 17
16 A ppendix V -C: Standard Slit Assembly Drawing[...]
-
Page 18
17 A ppendix V -D: Accessories Listing SP -2300i M onochromators & Spectrographs SP - 2355 SP - 2300i, 300mm Monoch romator: Micrometer adjustabl e entrance/exit slits, 90° optical path, internal image correction with ori ginal polished as pheric optics, a triple grating turret, exclusive SpectraDrive™ stepping motor sc anning system with 32[...]
-
Page 19
18 TDS- 429 Dual Light Source with 30 watt deuterium & 30 watt tungsten -halogen lamps. Inc ludes housing with light c ollection mirror, mounting flange, and power supply. Provides c ombined output from 190 to >2.0 µm. XS - 43 3 75 Watt Xenon Light Source includes power s upply, housing, mounting flange and light collection mirror. Provides[...]
-
Page 20
19 Filter Wheels and Order Sorting Filter Ass emblies FA - 2448 Six Position Filter Wheel Assembl y. Manual sample index ing, holds up to six samples, each 1.0” diameter; automated via SP Control Cable. Can be used wi th the SP -2 300 i. Requires FA- 2448 -F Filter Set or c ustomer-supplied f ilters of 25 mm (1 inch) diameter and 5 mm or less in [...]
-
Page 21
20 A ppendix V -E: Gratings for SP-2300i Grooves/mm Blaze Wavelength Standard Part Number Mechanical Limit Notes: † Bl az ed H ol og rap hi c, 19 0- 450 nm , op tim um ra ng e †† H ol ogr ap hi c, 450 - mec han ica l li mi t, op ti mum ra ng e ††† Holographic, 190-466 nm, optimum range Gold, Silver and Acton Exclusive VUV Reflective Coa[...]
-
Page 22
21 A ppendix V -F: Certification and Warranty Certification Princeton Instruments certifies that thi s instrument was thoroughly tested and f ound to meet the specif ications furnished by Princ eton Instruments when it was shipped f rom the factory. Warranty Princeton Instruments ins truments and accessorie s are warranted for a period of one f ull[...]
-
Page 23
22 A ppendix V -G: Drawings[...]
-
Page 24
23[...]
-
Page 25
24[...]