Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Profile Machined Aluminum Fixtures, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Profile Machined Aluminum Fixtures one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Profile Machined Aluminum Fixtures. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Profile Machined Aluminum Fixtures should contain:
- informations concerning technical data of Profile Machined Aluminum Fixtures
- name of the manufacturer and a year of construction of the Profile Machined Aluminum Fixtures item
- rules of operation, control and maintenance of the Profile Machined Aluminum Fixtures item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Profile Machined Aluminum Fixtures alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Profile Machined Aluminum Fixtures, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Profile service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Profile Machined Aluminum Fixtures.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Profile Machined Aluminum Fixtures item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MA CHINED ALUMINUM FIXTURES RSA offers a collection of leading edge precision des ign ed ma ch in ed fi xt ur es f or u se w it h: • 60 A mp - 1 o r 2 Ci rc ui t Bus way • 2 0 Am p - 1 or 2 C ircu it T rac k • 4 0 Am p - 2 Ci rcui t / 2 Ne utra l T rack . MACHINED FIXTURES include suc h u niq ue hi gh -t ec h features as lockable horizontal [...]
-
Page 2
• YOKES CAN ROT A TE UP TO 370º WITHOUT REPOSITIONING THE FIXTURE DUE TO THE OVERCENTER MECHANISM. (BUSWA Y ONL Y) • AUTO-EXTENDING / RETRACTING LAMP HOLDER. LAMPS EXTEND FOR EASY RELAMPING AND RETRACT TO OPTIMUM POSITION. THIS IS EXTREMEL Y HELPFUL WHEN DEALING WITH V ARYING ACCESSOR Y OR LAMP DIMENSIONS. • ACCESSORY RET AINER CAN ACCOMMODA[...]
-
Page 3
32 MR11 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 4.95” 5.66” 4.09” 2.36” 3.27” C L 2.75” BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke PM611 cb - MR11 for 60 Amp Busway W attage 20 watt | 35 watt Finish BK Black | WH White | AL Natural Aluminum PT Custom Finish ( specify) Ordering Exam[...]
-
Page 4
33 MR11 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 2.36” 1.06” 3.27” 3.06” 2.17” 3.27” 4.83” C L 4.12” BUSWA Y SURFACE Closed Back Machined Fixture w/ Integral T ransformer PM611 cbi - MR11 for 60 A[...]
-
Page 5
34 MR16 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 3.35” 5.75” 3.72” 2.98” 6.46” 4.73” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke PM612 cb - MR16 for 60 Amp Busway W attage 20 watt | 37 watt | 42 watt | 50 watt | 71 watt Finish BK Black | WH White | AL Natural Aluminum PT Custom F[...]
-
Page 6
35 MR16 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 3.68” 2.17” 4.99” 3.27” 2.98” 1.06” 3.72” C L 4.28” BUSWA Y SURFACE Closed Back Machined Fixture w/ Integral T ransformer PM612 cbi - MR16 for 60 A[...]
-
Page 7
36 AR70 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 7.51” 5.33” 4.34” 6.80” 4.59” 3.84” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke PM613 cb - AR70 for 60 Amp Busway W attage 20 watt | 50 watt Finish BK Black | WH White | AL Natural Aluminum PT Custom Finish ( specify) Ordering Exam[...]
-
Page 8
37 AR70 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 5.84” 3.66” 2.17” 4.52” 4.59” 1.06” 3.84” C L 5.13” BUSWA Y SURFACE Closed Back Machined Fixture w/ Integral T ransformer PM613 cbi - AR70 for 60 A[...]
-
Page 9
38 AR111 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 6.07” 7.76” 5.07” 5.59” 8.46” 5.93” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke PM614 cb - AR111 for 60 Amp Busway W attage 35 watt | 50 watt | 75 watt | 100 watt Finish BK Black | WH White | AL Natural Aluminum PT Custom Finish ([...]
-
Page 10
39 AR111 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 2.17” 7.19” 4.66” 6.27” 1.06” 5.07” 5.59” C L C L 8.33” BUSWA Y SURFACE Closed Back Machined Fixture w/ Integral T ransformer PM614 cbi - AR111 fo[...]
-
Page 11
40 P AR36 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 7.76” 5.07” 5.59” 8.46” 5.93” 6.08” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke PM615 cb - P AR36 for 60 Amp Busway W attage 35 watt | 50 watt Finish BK Black | WH White | AL Natural Aluminum PT Custom Finish ( specify) Ordering [...]
-
Page 12
41 P AR36 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 7.19” 4.66” 2.17” 6.27” 5.07” 1.06” 5.59” C L 8.33” BUSWA Y SURFACE Open Back Machined Fixture w/ Integral T ransformer PM615 cbi - P AR36 for 60[...]
-
Page 13
42 P AR16 120V MACHINED FIXTURES - Y OKE CLOSED BACK OPEN BACK Closed Back Machined Fixture w/ Y oke PM621 cb - P AR16 for 60 Amp Busway PM121 cb - P AR16 for 20 Amp 1 circuit track PM221 cb - P AR16 for 20 Amp 2 circuit track PM421 cb - P AR16 for 40 Amp 2 cct / 2 ntrl track W attage 75 watt max. Finish BK Black | WH White | AL Natural Aluminum PT[...]
-
Page 14
43 CLOSED BACK OPEN BACK P AR20 120V MACHINED FIXTURES - Y OKE Open Back Machined Fixture w/ Y oke PM622 ob - P AR20 for 60 Amp Busway PM122 ob - P AR20 for 20 Amp 1 circuit track PM222 ob - P AR20 for 20 Amp 2 circuit track PM422 ob - P AR20 for 40 Amp 2 cct / 2 ntrl track W attage 50 watt max. Finish BK Black | WH White | AL Natural Aluminum PT C[...]
-
Page 15
44 P AR30 120V MACHINED FIXTURES - Y OKE CLOSED BACK OPEN BACK Closed Back Machined Fixture w/ Y oke PM623 cb - P AR30 for 60 Amp Busway PM123 cb - P AR30 for 20 Amp 1 circuit track PM223 cb - P AR30 for 20 Amp 2 circuit track PM423 cb - P AR30 for 40 Amp 2 cct / 2 ntrl track W attage 75 watt max. (Short neck lamp only) Finish BK Black | WH White |[...]
-
Page 16
45 CLOSED BACK OPEN BACK P AR38 120V MACHINED FIXTURES - Y OKE Closed Back Machined Fixture w/ Y oke PM624 cb - P AR38 for 60 Amp Busway PM124 cb - P AR38 for 20 Amp 1 circuit track PM224 cb - P AR38 for 20 Amp 2 circuit track PM424 cb - P AR38 for 40 Amp 2 cct / 2 ntrl track W attage 250 watt max. Finish BK Black | WH White | AL Natural Aluminum P[...]
-
Page 17
46 ES16 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ ST ANDARD BALLAST ENCLOSURE CLOSED BACK W/ T ALL BALLAST ENCLOSURE Closed Back Machined Fixture w/ Integral Ballast PM636 cb - ES16MH for 60 Amp Busway PM136 cb - ES16MH for 20 Amp 1 circuit track PM236 cb - ES16MH for 20 Amp 2 circuit track PM436 cb - ES16MH for 40 A mp 2 cct / 2 ntr l tr ack[...]
-
Page 18
47 CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST CDMR111 MET AL HALIDE MA CHINED FIXTURES Closed Back Machined Fixture w/ Integral Ballast PM637 cb - CDMR111MH for 60 Amp Busway PM137 cb - CDMR111MH for 20 Amp 1 circuit track PM237 cb - CDMR111MH for 20 Amp 2 circuit track PM437 cb - CDMR111MH for 40 Amp 2 cct [...]
-
Page 19
48 P AR20 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST Closed Back Machined Fixture w/ Integral Ballast PM632 cb - P AR20MH for 60 Amp Busway PM132 cb - P AR20MH for 20 Amp 1 circuit track PM232 cb - P AR20MH for 20 Amp 2 circuit track PM432 cb - P AR20M H fo r 40 Amp 2 c ct / [...]
-
Page 20
49 CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST P AR30 MET AL HALIDE MA CHINED FIXTURES Closed Back Machined Fixture w/ Integral Ballast PM633 cb - P AR30MH for 60 Amp Busway PM133 cb - P AR30MH for 20 Amp 1 circuit track PM233 cb - P AR30MH for 20 Amp 2 circuit track PM433 cb - P AR30MH for 40 Amp 2 cct / 2 n[...]
-
Page 21
50 P AR38 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST Closed Back Machined Fixture w/ Integral Ballast PM634 cb - P AR38MH for 60 Amp Busway PM134 cb - P AR38MH for 20 Amp 1 circuit track PM234 cb - P AR38MH for 20 Amp 2 circuit track PM434 cb - P AR38MH for 40 Amp 2 cct / 2 n[...]
-
Page 22
51 CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST T4 G8.5 MET AL HALIDE MA CHINED FIXTURES Closed Back Machined Fixture w/ Integral Ballast PM635 cb - T4G8.5MH for 60 Amp Busway PM135 cb - T4G8.5MH for 20 Amp 1 circuit track PM235 cb - T4G8.5MH for 20 Amp 2 circuit track PM435 cb - T4G 8.5M H fo r 40 Amp 2 c ct / 2 n trl trac k W attage 20 watt | 39 wa[...]
-
Page 23
52 T6 G12 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST 39W/70W Closed Back Machined Fixture w/ Integral Ballast PM638 cb - T6 G12MH for 60 Amp Busway PM138 cb - T6 G12MH for 20 Amp 1 circuit track PM238 cb - T6 G12MH for 20 Amp 2 circuit track PM438 cb - T6 G12MH for 40 Amp 2 cct / 2 ntrl track W attage 39 watt | 70 w[...]
-
Page 24
53 PM632cb-39-AL-120 P AR20MH Machined Closed Back Integral Ballast PM613cbi-50-AL-120-S12 MR16 Machined Closed Back Integral T ransformer with 12” Stem PM624ob-250-AL P AR38 Machined Open Back with hardwired 5” Monopoint Canopy - (see page 77) MACHINED FIXTURES[...]