QSC Audio 722AZ manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of QSC Audio 722AZ, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of QSC Audio 722AZ one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of QSC Audio 722AZ. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of QSC Audio 722AZ should contain:
- informations concerning technical data of QSC Audio 722AZ
- name of the manufacturer and a year of construction of the QSC Audio 722AZ item
- rules of operation, control and maintenance of the QSC Audio 722AZ item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of QSC Audio 722AZ alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of QSC Audio 722AZ, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the QSC Audio service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of QSC Audio 722AZ.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the QSC Audio 722AZ item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    TD-000145- 00 rev .A *TD-000145-00* BASIS 722az 8x8 Control and Monitoring Signal Processor Hardware Manual[...]

  • Page 2

    2 IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS The lightning flash with arrowhead symbol wit hin an equilateral tri angle is intended to al ert the user to the presence of uninsula ted “dangerous” voltage within the product’ s enclosure t hat may be of sufficien t magnitude to constit ute a risk of electri c shock to humans. The [...]

  • Page 3

    3 1- Power indicator 2- Diagnostic indicator 3- Network status indicators 4- Port connection status indicators 5- Multi-function push buttons 6- Display 7- Rotary select/accept knob 8- Reset push switch (recessed) 9- DataPorts 10- Analog inputs 11- Monitor chain in/out 12- Relay outputs 13- Logic outputs 14- Omni inputs 15- RS-232 port 16- Network [...]

  • Page 4

    4 Block Diagram Introduction - Networ king the BASIS 722az The BASIS 722az includes an RJ-45 network connection port on the r ear panel, which is labeled "QSControl". All data communicati ons between the BASIS 722az and a control computer , such as a PC runni ng the QSControl.net server or client application, takes plac e via this rear pa[...]

  • Page 5

    5 Example 1- QSControl. net X-over mode: This example illustrates the simplest connection you can make between the BASIS 722az and a computer . Y ou simply use a CA T -5 crossover cable connected between the BASIS 722az rear p anel QSControl port and a computer's network interface card, (NIC). Not e that the computer’ s NIC must support 10BA[...]

  • Page 6

    6 QSControl Port BASIS 722az QSControl.net NIC CA T - 5 Cable CA T -5 Cable Managed Switch CA T -5 Cable Example 3- Managed Switch (conf igured with multiple VLANS): This example illustrates a managed Ethernet network. An managed switch is used to partition the network into two domains; one f or QSControl traffic and one for all non-QSControl traff[...]

  • Page 7

    7 Unpacking There are no special unpacking precautions. However , it is recomm ended you keep the original pa cking material for reuse in the rare event that service be required. If service is required and the or iginal packing material is not available, ensure that the unit is adequately protected for shipment (strong box of appropriate size, suff[...]

  • Page 8

    8 Computer Requirements & Software Installation Installing QSControl.net is easy . All you need to do is choose the folder where the program is to be stored (the default settin g is acceptable for most applications). We recommend your system meet the following minimum requirements: 1- IBM PC compatible computer with a Pentium 4 processor . 2- P[...]

  • Page 9

    9 Connections AC Power Cord Insert the molded receptacle of the AC power cord into the AC power inlet on the back of the BASIS 722az. Plug the AC line connector into the AC outlet. The power supply will accept from 100 to 240 V olts AC, 47 to 440 Hertz, without any changes. If a different type of IEC power cord is required than supplied with your 7[...]

  • Page 10

    10 Monitor Chain conn ection. See explanation, at left. In Out Monitor Chain The MONITOR CHAIN connector is a 5-pin terminal block connector . Input and output c on- nections are balanced. The center pin is the shield connection for both the input and output of the monitor chain. Connection is shown at right. The left-most + and - terminals are for[...]

  • Page 11

    11 LED Indicators (continued) QSControl and CobraN et Network Status (Po rt) Indicators- There is a group of three LEDs on the front and rear panels of the BASIS 722az labeled RX, TX and LINK. These indicate the connection status of the BASIS 722az to the QSControl net- work. Their functions are described below . Note: the Port indica tors on rear [...]

  • Page 12

    12 LCD Navigation Map (typical) Left side buttons h ave screen dependent function s. This read-o nly screen is the “out of the box” defa ult dis- play after power up. This is the most desired inf ormation when first sett ing up a net- work system. Once user moves to a di fferent scr een, the last screen acc essed becomes the new po wer up defau[...]

  • Page 13

    13 Getting Started This section outlines one of the simpler methods of getting familiar with your BASIS and the QSControl.net software. The goal o f this procedure is to get your computer and the BASIS connected and co mmunicating and the QSControl.net software installed and runnin g. After the software is installed and running, refer to the softwa[...]

  • Page 14

    14 Getting Started (continued) 17- Select Device , Add New Device , from the menu. A new window will open prompting you to name the device. Name it logically , such as BASIS 1, or similar . Select the Device T ype and select BASIS 722az. At the Password prompt, enter “qsc” (lower case, no quo- tation marks). This is the device password, separat[...]

  • Page 15

    15 Operation QSControl Port The QSControl port operates on a 10BaseT Ethernet network. This por t is one of the primary means for connecting QSControl.net to the BASIS. The port may connect directly to a PC's 10BaseT or 10/100 (auto-sensing or auto-neg otiating) network interface card usin g a crossover cable. Data from the QSControl port may [...]

  • Page 16

    16 Utility/Diagnostic Fu nctions (continued) RS-232 Communications Procedure: 1) Connect the RS-232 port of the BASIS 722az to an unused serial po rt (COM port) of a PC using a normal (straight through) serial cable. 2) Open the HyperT erminal program. This program is usually started by clicking the Windows Start icon, selecti ng Programs , then Ac[...]

  • Page 17

    17 Utility/Diagnostic Fu nctions (continued) T elnet Access The RS-232 features can also be accessed via T elnet. The Micros oft T elnet application is a Windows program. Consult Windows documentation for T e lnet information. Basic procedure for opening a T elnet session: 1 - T o open the T elnet session- Click Start , select Run , type “T elnet[...]

  • Page 18

    18 Preliminary Specification IN OUT THRU Dynamic Range (A ES-17, -60dB Method, all sensit ivities) unweighted >115dB >112dB >110dB A weighted >118dB >115dB >113dB Distortion (20Hz-20 KHz, all sen sitivities) +4dBu (max) <0.009% THD+N <0.009% THD+N <0.009% THD+N 2dB below clip (max) <0.009% THD+N <0.009% THD+N <0.[...]

  • Page 19

    19 Preliminary Specification Control Room Foldba ck Monitoring Connector T ype 5-pin "Phoenix Style" (a.k.a . "Euro Style") detachable terminal blocks Pinout 1:+(input) 2:-(input) 3:CHASSIS GND 4:-(output) 5:+(output) T ap points 8 internal input, 8 internal output, 8 amplifier (pre-, post-, amplifier) software selectable Monito[...]

  • Page 20

    QSC Audio Products, Inc. 1675 MacArthur Boulevard Costa Mesa, California 92626 USA ©2004 “QSC” and the QSC logo are registered with the U.S. Patent and T rademark Office. How to Contact QSC Audio Products Mailing address: QSC Audio Products, Inc. 1675 MacArthur Boulevard Costa Mesa, CA 92626-1468 USA T elephone Number s: Main Number (714) 754-[...]