Go to page of
Similar user manuals
-
Network Card
Quatech DSC-200/300
39 pages 0.46 mb -
Network Card
Quatech ABDG-ET-DP501/IN5010
8 pages 0.77 mb -
Network Card
Quatech QSC-100
32 pages 0.41 mb -
Network Card
Quatech SSCLP-200
48 pages 0.58 mb -
Network Card
Quatech ESC-100
35 pages 0.52 mb -
Network Card
Quatech QSU-200
55 pages 2.04 mb -
Network Card
Quatech SPPXP-100
24 pages 0.54 mb -
Network Card
Quatech DSU-200
55 pages 2.04 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Quatech DS-100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Quatech DS-100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Quatech DS-100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Quatech DS-100 should contain:
- informations concerning technical data of Quatech DS-100
- name of the manufacturer and a year of construction of the Quatech DS-100 item
- rules of operation, control and maintenance of the Quatech DS-100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Quatech DS-100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Quatech DS-100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Quatech service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Quatech DS-100.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Quatech DS-100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
DS-100 Two Channel RS-232 Asynchronous Serial Adapter for ISA compatible machines User's Manual QUATECH, INC. TEL: (330) 655-9000 5675 Hudson Industrial Parkway FAX: (330) 655-9010 Hudson, Ohio 44236 http://www.quatech.com INTERFACE CARDS FOR IBM PC/AT AND PS/2[...]
-
Page 2
Warranty Information Quatech Inc. warrants the DS-100 to be free of defects for one ( 5) years from the date of purchase. Quatech Inc. will repair or replace any adapter that fails to perform under normal operating conditions and in accordance with the procedures outlined in this document during the warranty period. Any damage that results from imp[...]
-
Page 3
© 2001, Quatech, Inc. NOTICE The information contained in this document cannot be reproduced in any form without the written consent of Quatech, Inc. Likewise, any software programs that might accompany this document can be used only in accordance with any license agreement(s) between the purchaser and Quatech, Inc. Quatech, Inc. reserves the righ[...]
-
Page 4
Declaration of Conformity Manufacturer's Name: Quatech Inc. Manufacturer's Address: 5675 Hudson Industrial Parkway Hudson, Ohio 44 236 (USA) Application of Council Directive: 89/336/EEC Standards to which Conformity is Declared: * EN50082-1 EN61000 -4-2, EN6 1000-4-3 , EN61000 -4-4 * CISPR 22 (EN55022) Type of Equipment: Information Techn[...]
-
Page 5
Table of Contents 8-1 9. Troubleshooting .................................................... 6-4 8. Specifications ....................................................... 6-1 7. External Connections ............................................... 5-2 6.1 Interrupt Sharing .................................................... 5-1 6. Interrupt Level [...]
-
Page 6
1. General Information The Quatech, Inc. DS-100 provides two RS-232 asynchronous serial communication interfaces for IBM-compatible personal computer systems using the 16-bit ISA (Industry Standard Architecture) expansion bus. The DS-100's serial ports are implemented using 16550 Universal Asynchronous Receiver/Transmitters (UARTs). The 16550 [...]
-
Page 7
(This Page Intentionally Left Blank) 1-2 Quatech Inc.[...]
-
Page 8
2. Installation If the default address and interrupt settings are sufficient, the DS-100 can be quickly installed and put to use. The factory defaults are listed in Figure 1. YES 3 2F8 hex Serial 1 YES 4 3F8 hex Serial 0 ENABLED IRQ ADDRESS PORT Figure 1 --- Default address and IRQ settings for DS-100 The output of the DS-100 is two 9-pin D-connect[...]
-
Page 9
IRQ 2 IRQ 3 IRQ 4 IRQ 5 IRQ 6 IRQ 7 IRQ 10 IRQ 11 IRQ 12 IRQ 14 IRQ 15 (Diagram not to scale) SW 2 Serial 0 SW 1 Serial 0 SW 3 Serial 1 SW 4 Serial 1 J3 J4 Serial 0 Serial 1 J2 J5 J6 Serial 0 Serial 1 CN1 CN2 16750 UART 16750 UART RN1 RN2 RN3 RN4 14.7456 OSC QUAT ECH INC DS-100 REV I Figure 2 --- Diagram of DS-100 2-2 Quatech Inc.[...]
-
Page 10
3. Windows 2000 Configuration Windows 2000 maintains a registry of all known hardware installed in the computer. Inside the hardware registry Windows 2000 keeps track of all of the system resources, such as I/O locations, IRQ levels, and DMA channels. The “Add New Hardware Wizard” utility in Windows is designed to add new hardware and update th[...]
-
Page 11
2. Double click on the “Add New Hardware” icon. 3-2 Quatech Inc.[...]
-
Page 12
3. The next window will be the “Welcome to the Hardware Wizard”, click “Next”. 4. Next choose the “Add/Troublshoot a device” radio button, click “Next”. 3-3 Quatech Inc.[...]
-
Page 13
3-4 Quatech Inc.[...]
-
Page 14
3-5 Quatech Inc.[...]
-
Page 15
3-6 Quatech Inc.[...]
-
Page 16
7. Next select “Ports (COM & LPT)”, click “Next”. 3-7 Quatech Inc.[...]
-
Page 17
8. In the next window under manufac ture select “(Standard port types), and under Models select “Communications Port. Because Windows will not detect plug and play you will have to manually enter the settings. Click “OK”. 3-8 Quatech Inc.[...]
-
Page 18
9. Next you will have to change the “Input/Output Range” to a setting that is not in use “No conflicts” by choosing a different “Basic Configuration”. . 3-9 Quatech Inc.[...]
-
Page 19
10. The “Input Request” (IRQ) must be set to corresponds with the jumpers setting on the DS-100 board. 3-10 Quatech Inc.[...]
-
Page 20
Once you have chosen the IRQ that corresponds with the setting on the Quatech DS-100 card the window will display “no conflicts” and the red circle with a slash of the “Input/Output Range” will not be present. 3-11 Quatech Inc.[...]
-
Page 21
11. Next Windows will begin the install the hardware, click “Next”. 3-12 Quatech Inc.[...]
-
Page 22
12. Next the “Completing the Add/Remove Hardware Wizard” will appear, click “Finish”. 3-13 Quatech Inc.[...]
-
Page 23
13. Next Windows will prompt you to restart the computer so the changes will take effect and show the new ports. Select “No” to install the second port. Repeat the same process to install the second channel. Finally, in order for the changes to take effect you will have to restart the computer. 3-14 Quatech Inc.[...]
-
Page 24
4. Windows 95 Configuration Windows 95 maintains a registry of all known hardware installed in your computer. Inside this hardware registry Windows 95 keeps track of all of your system resources, such as I/O locations, IRQ levels, and DMA channels. The "Add New Hardware Wizard" utility in Windows 95 was designed to add new hardware and up[...]
-
Page 25
6. An Install From Disk dialog box should pop up. Insert the diskette with the Quatech INF files on it, select the correct drive letter, and click the “OK” button. Windows 95 automatically browses the root directory for an INF file that defines configurations for Multi-function Adapters. If no INF files are found, click the “Browse” or “O[...]
-
Page 26
4.2 Viewing and Changing Resources with Device Manager The following instructions provide step-by-step instructions on viewing and changing resources of the DS-100 in Windows 95 using the “Device Manager” utility. Select Start|Help from within Windows 95 for additional information on this utility. 1. Double click the “System” icon inside th[...]
-
Page 27
5. Click the “Resources” tab located along the top of the properties box. Confirm that the resources Windows 95 has allocated for the D S-100 match the hardware configuration. To modify any of the resource settings click the resource name and click the “Change Setting” button. If the “A utomatic Settings” option is selected, it will hav[...]
-
Page 28
10. Use the Logical COM Ports numbers to access the serial ports on your D S-100 through your software applications. Note: The Logical COM Port name is assigned to your ports by Windows 95. This name is required by a Windows 95 application when accessing a particular port. 3-19 Quatech Inc.[...]
-
Page 29
(This Page Intentionally Left Blank) 3-20 Quatech Inc.[...]
-
Page 30
5. Addressing Ports 5.1 Setting the address The base address of each port of the DS-100 is set using two DIP switch packs. When setting the address selection switches, a switch in the "ON" position specifies that the corresponding address line must be a logic 0 for the port to be selected. Similarly, a switch in the "OFF" positi[...]
-
Page 31
Switch on bit = 0 Switch off bit = 1 Serial 0 uses SW1 and SW2 Serial 1 uses SW3 and SW4 ON 123456 78 8 82 1 F 4 8 123456 ON 02 1 3 0 00 0 0 0 SW 1 SW 2 enable/disable ON 123456 78 8 82 1 F 4 8 123456 ON 02 0 2 0 00 0 0 0 SW 3 SW 4 Factory default setting for Serial 2 --- 02F8 hex (COM2) ON 123456 78 8 82 0 E 4 8 123456 ON 02 1 3 0 00 0 0 0 Example[...]
-
Page 32
The standard addresses for serial ports COM1 and COM2 are listed in Figure 7. Recommended addresses for serial ports COM3 and COM4 are also listed. The switch settings for these addresses are shown in Figure 6. 02E8 hex COM4 Recommendations only. No official standards exist for COM3 and COM4. 03E8 hex COM3 Factory default for Serial 1. 02F8 hex COM[...]
-
Page 33
6. Interrupt Level (IRQ) The DS-100 allows the use of any interrupt level in the range IRQ2 to IRQ7, IRQ10 to IRQ12, IRQ14, or IRQ15, selected using jumper block J3 (for Serial 0) or J4 (for Serial 1). In Figure 9, the factory default settings for Serial 0 and Serial 1 are shown. To select a different IRQ, move the jumper to the appropriate positio[...]
-
Page 34
6.1 Interrupt Sharing Both ports on the DS-100 can share the same interrupt leve l or they can share their interrupt with another Quatech adapter supporting sharable interrupts. Jumper J2 can be used to connect the UART generated interrupt directly to the selected IRQ or to enable the interrupt sharing circuit. In either case, the software driving [...]
-
Page 35
7. Exter nal Connections EIA/TIA -232-E devices are classified by their function as either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE). Generally, data terminal equipment is defined as the communication source and data communication equipment is defined as the device that provides a communication channel between two DTE-type[...]
-
Page 36
To simplify connections to other devices, each port on the DS-100 is equipped with a jumper block that allows the port to be configured as either a DTE- or DCE-type device. This allows the DS-100 to communicate with either DTE- or DCE-type devices without using a null modem cable. J5 is used for Serial 0 and J6 is used for Serial 1. The DTE/DCE sel[...]
-
Page 37
The DS-100 connects to peripheral equipment through male D-9 connectors. Adapters are available to convert these connectors into standard D-25 male connectors. The standard serial port connections are listed in Figure 14 . 22 9 22 9 Ring Indicator (RI) 4 7 5 8 Clear To Send (CTS) 5 8 4 7 Request To Send (RTS) 20 4 6 6 Data Set Ready (DSR) 7 5 7 5 S[...]
-
Page 38
(This Page Intentionally Left Blank) DS-100 User’s Manual 6-4[...]
-
Page 39
8. Specifications BAUD RATES: 6600 5500 4300 2470 1000 115.2 25% TRAN 20% TRAN 15% TRAN 10% TRAN 4% TRAN MAXIMUM LOAD (pF) DATA RATE (kbaud ) NOTE 1: The signal transition time ratio is defined as the percentage of the unit interval or bit time (the inverse of the data rate ) that is occupied by the signal transitioning from -3V to +3V. EI A/TIA-23[...]
-
Page 40
-12 volts 60 mA max TEMPERATURE: Operating 0° to 70° Storage -50° to 80° HUMIDITY: 10% to 90% APPROVALS AND CERTIFICATIONS: FCC, CE, Windows 95, Windows NT OS SUPPORT: Windows 2000, Windows 95, Windows 3.1, Windows NT 4.0, OS/2 2.0, DOS 6.22, UNIX 7-2 Quatech Inc.[...]
-
Page 41
9. Troubleshooting Listed here are some common problems and frequent causes of those problems. Suggestions for corrective action are given. If the information here does not provide a solution, contact Quatech Customer Service for technical support. Any unauthorized repairs or modifications will void the DS-100' s warranty. Computer will not bo[...]
-
Page 42
DS-100 User's Manual Revision 4.21 March 2004 P/N: 940-0048-421[...]