Quatech DSCLP/SSCLP-100 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Quatech DSCLP/SSCLP-100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Quatech DSCLP/SSCLP-100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Quatech DSCLP/SSCLP-100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Quatech DSCLP/SSCLP-100 should contain:
- informations concerning technical data of Quatech DSCLP/SSCLP-100
- name of the manufacturer and a year of construction of the Quatech DSCLP/SSCLP-100 item
- rules of operation, control and maintenance of the Quatech DSCLP/SSCLP-100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Quatech DSCLP/SSCLP-100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Quatech DSCLP/SSCLP-100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Quatech service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Quatech DSCLP/SSCLP-100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Quatech DSCLP/SSCLP-100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DSCLP/SSCLP-100 Two Channel Low Profile RS-232 Asynchronous Communications Adapte r for PCI bus User's Manual QUATECH, INC. TEL: (330) 655-9000 5675 Hudson Industrial Parkway FAX: (330) 655-9010 Hudson, Ohio 44236 http://www.quatech.com 1 DSCLP/SSCLP-100 User's Manual[...]

  • Page 2

    WARRANTY INFORMATION Quatech, Inc. warrants the DSCLP-100 or SSCLP-100 to be free of defects for five (5) years from the date of purchase. Quatech, Inc. will repair or replace any board that fails to perform under normal operating conditions and in accordance with the procedures outlined in this document during the warranty period. Any damage that [...]

  • Page 3

     2006, Quatech, Inc. NOTICE The information contained in this document cannot be reproduced in any form without the written consent of Quatech, Inc. Likewise, any software programs that might accompany this document can be used only in accordance with any license agreement(s) between the purchaser and Quatech, Inc. Quatech, Inc. reserves the rig[...]

  • Page 4

    Declaration of Conformity Manufacturer's Name: Quatech Inc. Manufacturer's Address: 5675 Huson Industrial Parkway Akron, Ohio 44236 (USA) Application of Council Directive: 89/336/EEC Standards to which Conformity is Declared: * EN50081-1 (EN55022, EN60555-2, EN60555-3) * EN50082-1 (IEC 801-2, IEC 801-3, & IEC 801-4) Type of Equipment:[...]

  • Page 5

    Table of Contents 39 10 Troubleshooting ................................. 37 9 Specifications ...................................... 36 8 PCI Resource Map ............................... 34 7 External Connections ............................ 32 6.3.1 QTPCI.EXE ..................................... 31 6.3 DOS and other operating systems ............[...]

  • Page 6

    1 General Information The Quatech, Inc. DSCLP-100 (two-port) and SSCLP-100 (one-port) provide RS-232 asynchronous serial communication interfaces for Low Profile I BM-compatible personal computer systems using the PCI expansion bus. The DSCLP-100 uses Quatech's new Enhanced Serial Adapter design. Legacy serial port data rates are limited to a [...]

  • Page 7

    2 Hardware Configuration The DSCLP-100 is automatically configured at boot time by the computer's BIOS or operating system. There are no required switches or jumpers to set for installation. This chapter lists a number of optional jumper settings that control various hardware features. Jumpers J2, J4-J5 are grouped together at the end of the b[...]

  • Page 8

    2.3 Force High-Speed UART Clock (X2 or X 4 , J4-J5) These jumpers force an increase of the UART input clock frequency by a factor of two or four. This feature can allow legacy software to use baud rates above 115,200 bits per second. It is also useful if the serial port device driver does not directly support setting the higher baud rates through t[...]

  • Page 9

    3 Hardware Installation 1. Turn off the power of the computer system in which the DSCLP-100 is to be installed. 2. Remove the system cover according to the instructions provided by the computer manufacturer. 3. Make any desired optional jumper setting changes. 4. Install the DSCLP-100 in any empty PCI expansion slot. The board should be secured by [...]

  • Page 10

    4 Address Map and Special Registers This chapter explains how the two UARTs and special registers are addressed, as well as the layout of those registers. This material will be of interest to programmers writing driver software for the DSCLP-100. 4.1 Base Address and Interrupt Level (IRQ) The base address and IRQ used by the DSCLP-100 are determine[...]

  • Page 11

    4.2 Enabling the Special Registers The DSCLP-100 contains two unique registers, an Interrupt Status Register and an Options Register. These registers are enabled when the SPAD jumper (J2) is removed (factory default). They replace the UART Scratchpad Register on accesses to register address 7. The Interrupt Status Register and Options Register are [...]

  • Page 12

    4.4 Options Register The Options Register allows software to identify the DSCLP-100 as a Quatech Enhanced Serial Adapter. It also allows software to set the UART clock rate multiplier. Figure 9 shows the structure of the Options Register. The powerup default of the Options Register is all bits zero. Clock rate multiplier bit 0 RR0 0 Clock rate mult[...]

  • Page 13

    4.4.2 Clock Rate Multiplier A standard RS-232 serial port operates at a clock speed of 1.8432 MHz. In order to achieve higher data rates, Quatech Enhanced Serial Adapters can operate at two times, four times or even eight times this standard clock speed. This is controlled by the clock rate multiplier bits in the Options Register. Software can dete[...]

  • Page 14

    5 Windows Configurations 5.1 Windows Mille nnium 1. After inserting the DSCLP-100 for the first time the "Add New Hardware Wizard" will begin. Select "Search for the best driver for your device.". Check the "Removable media" and "Specify location" box. Click the "Next" button. 2. Window will locate [...]

  • Page 15

    5.2 Windows 2000 1. After inserting a DSCLP-100 for the first time, the "Add New Hardware Wizard will appear at start up. Click the "OK" button. 2. The following dialog box will be displayed. I nsert the Quatech COM CD (shipped with the device). Click the "OK" button. 3. The following dialog box will display the appropriate[...]

  • Page 16

    5.3 Windows 98 1. After inserting a DSCLP-100 for the first time, the "Add New Hardware Wizard will appear at start up. Click the "Next" button. 2. Select "Search for the best driver for you r device". Click the "Next" button. 3. On the next dialog, select the " CD-ROM DRIVE " check box. Insert the Quate[...]

  • Page 17

    4. The following dialog box will display the appropriate INF file on the disk in the drive. Click the "Next" button. 5. Window will copy the INF file from the disk and display a final dialog indication that the process is complete. Click the "Finish" button. 5.4 Windows 95 Windows 95 maintains a registry of all known hardware in[...]

  • Page 18

    5.5 Using the "New Hardware Found" Wizard The following instructions provide step-by-step instructions on installing the DSCLP-100 in Windows 95 using the "New Har dware Found" wizard. 1. After booting the computer with a newly-installed DSCLP-100, the "New Hardware Found" dialog box will appear. If you have never inst[...]

  • Page 19

    NOTE : You may be able to skip this step if you are certain that your system has the latest version of these files installed. If you do not have your Windows 95 install disks immediately available, click "OK" anyway. A dialog box appears with an option to Skip the files. Click the Skip button and the files will not be installed. This is a[...]

  • Page 20

    5.6 Viewing Resources with Device Manager This discussion applies equally to Windows 95/98/ME and 2000/XP . The following instructions provide step-by-step instructions on viewing resources used by the DSCLP-100 in Windows using the "Device Manager" utility. Select Start|Help from within Windows for additional information on this utility.[...]

  • Page 21

    Figure 12--- Windows Device Manager 6. The DSCLP-100 serial ports are also listed under the group Ports ( COM and LPT). Windows 95 does not assign COM1-COM4 to ports addressed at nonstandard locations. The DSCLP-100 ports will be enumerated starting with COM5 (or higher) even if lower logical numbers are available. 7. Select any of the Quatech Seri[...]

  • Page 22

    Figure 13 --- Windows Device Manager 9. Use the Logical COM Port names to access the serial ports on your DSCLP-100 through your software applications. Note: The Logical COM Port name is assigned to your ports by Windows . This name is required by a Windows application when accessing a particular p ort. 22 DSCLP/SSCLP-100 User's Manual[...]

  • Page 23

    5.6.1 Changing Resource Settings with Device Manager 1. Start the Windows 95/98/ME Device Manager . 2. Double click on the hardware class Multi-Port Serial Adapters to list hardware devices in the class. 3. The DSCLP-100 “parent device” belongs to this hardware class. The full device name for the DSCLP-100 is Quatech DSCLP-100: Dual-Port RS-232[...]

  • Page 24

    4. Open the Properties dialog for the DSCLP-100 device, then click the Resources tab to view the Input/Output Range and Interrupt Request resource allocations. Do not change these settings without specific instructions from a Quatech Technical Support Specialist. To exit without saving changes, click the “cancel” button. 5. Open the Properties [...]

  • Page 25

    The X2 clock mode locks the ports hardware clock at double the standard rate. The baud rate the port runs at will always be double the rate requested by the applications. This mode is useful 230,400 X2 The X1 clock mode mimics a standard COM port. The hardware drivers lock the clock to the standard rate. The port will run at the baud rate requested[...]

  • Page 26

    The X8 clock mode locks the ports hardware clock at eight times the standard rate. The baud rate the port runs at will always be eight times the rate requested by the application. This mode is useful for legacy applications which cannot request baud rates over 115.200. 921,600 X8 The X4 clock mode locks the ports hardware clock at four times the st[...]

  • Page 27

    8. Click the "Port Settings" tab and then click the "Advanced" button. The DSCLP-100 driver will display a custom Advanced Port Settings control, which allows the ports UART compatibility mode and FIFO threshold levels to be configured. The threshold values of full-scale for the transmit buffer and ¾-scale for the receive buffe[...]

  • Page 28

    28 DSCLP/SSCLP-100 User's Manual[...]

  • Page 29

    6 Other Operating Systems Device drivers for Windows NT and OS/2 are also available for the DSCLP-100. The board can be used under DOS and other operating systems as well in many circumstances. The software described below can be downloaded from the Quatech web site if it did not come with the board. 6.1 Windows NT The Windows NT device driver is i[...]

  • Page 30

    6.3.1 QTPCI.EXE Quatech's "QTPCI" utility supplies the information required when modifying the serial port settings of the application. This program should be run from real DOS, not in a Windows DOS box. Figure 14 shows the Basic Mode display for the DSCLP-100 after the "Q" key has been pressed. In this example, the DSCLP-1[...]

  • Page 31

    Figure 15 shows the Expert Mode display for the DSCLP-100 after the "Q" key has been pressed. The information from the Basic Mode display is presented along with more details such as the Vendor and Device IDs, PCI Class Code, size of memory and I/O regions, etc. Pressing the "N" key will show similar information for all non-Quat[...]

  • Page 32

    7 External Connections RS-232-C devices are classified by their function as either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE). Generally, data terminal equipment is defined as the communication source and data communication equipment is defined as the device that provides a communication channel between two DTE-type devices[...]

  • Page 33

    The DSCLP-100 is a DTE device which connects to peripheral equipment through a single male D- 25 connector, or using the adapter cable, two male D- 9 connectors. The standard serial port connections are listed in Figure 18. 5 1 5 7 GND 9 23 9 22 RI 1 25 1 8 DCD 6 13 6 6 DSR 4 19 4 20 DTR 8 12 8 5 CTS 7 11 7 4 RTS 2 10 2 3 RxD 3 9 3 2 TxD D-9 D-25 D[...]

  • Page 34

    8 PCI Resource Map Listed below are the PCI resources used by the DSCLP-100. Such information may be of use to customers writing their own device drivers or other custom software. A detailed description of the DSCLP-100's UARTs is available on the Quatech web site. (all numbers in hex) PCI Vendor ID: 0x135C Quatech, Inc. PCI Device ID: 0x0180 [...]

  • Page 35

    9 Specifications Bus interface: PCI, 32-bit bus, Universal Voltage Signaling IBM -compatible computers Dimensions: approx. 5.0" x 3.7" Serial ports Controller: 16550 with 16-byte FIFOs Interface: DSCLP: One male D- 25 connector (Two male D-9 connectors using adapter cable .) SSCLP: one male D-9 connector. Transceivers: ICL3245CA High-leve[...]

  • Page 36

    4800 4300 3300 1570 800 115.2 2000 1630 1100 900 330 230.4 1100 900 670 430 100 460.8 470 430 300 100 N/A 921.6 25% trans time 20% trans time 15% trans time 10% trans time 4% trans time Maximum Load (pF) Data Rate (kbaud) Note 1: The signal transition time ratio is defined as the percentage of the unit interval or bit time (the inverse of the data [...]

  • Page 37

    10 Troubleshooting Listed here are some common problems and frequent causes of those problems. If the information here does not provide a solution, contact Quatech technical support. Any unauthorized repairs or modifications will void the DSCLP-100's warranty. Computer will not boot up. 1. Is the DSCLP-100 properly inserted? Remove the card an[...]