Go to page of
Similar user manuals
-
Modem
RAD Data comm 146
10 pages 0.74 mb -
Network Router
RAD Data comm BR-ASX01
39 pages 0.11 mb -
TV Converter Box
RAD Data comm AMC-101
65 pages 0.63 mb -
Network Router
RAD Data comm MBE10-8D
58 pages 1.98 mb -
Network Card
RAD Data comm IPmux-11
148 pages 1.32 mb -
IP Phone
RAD Data comm Vmux-2100 Voice Trunking Gateway
118 pages 2.52 mb -
Network Router
RAD Data comm Modular Access Device with Integrated Router
224 pages 2.88 mb -
Network Router
RAD Data comm IPmux-16
99 pages 1.23 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of RAD Data comm AMC-101, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of RAD Data comm AMC-101 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of RAD Data comm AMC-101. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of RAD Data comm AMC-101 should contain:
- informations concerning technical data of RAD Data comm AMC-101
- name of the manufacturer and a year of construction of the RAD Data comm AMC-101 item
- rules of operation, control and maintenance of the RAD Data comm AMC-101 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of RAD Data comm AMC-101 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of RAD Data comm AMC-101, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the RAD Data comm service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of RAD Data comm AMC-101.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the RAD Data comm AMC-101 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
AMC-101 Universal Media Converter and Repeater Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications. No part of this publicatio n may be rep roduced in any for m whatsoever w ithout prio r written ap proval by RAD Data Communications. No representation or warranties for fitness for[...]
-
Page 2
[...]
-
Page 3
Warranty This RAD produ ct is warranted agains t defects in ma terial and workmanshi p for a period of one y ear from date of shipme nt. Duri ng the warranty period, RAD wi ll, at its option, either repai r or replace products which prove to be defective. For warranty service or repair, thi s product must be retu rned to a service fac ility design [...]
-
Page 4
Safety Warnings The exc lamation point within a triangl e is intended to warn th e operator or service personnel of operati on and maintenance f actors relating to the product and i ts operating environment which could pose a safety hazard. Alwa ys observ e stand ard safety precaut ions durin g install ation, o peratio n and maintenan ce of t his p[...]
-
Page 5
Regulatory Information FCC-15 User Information This equipment has b een tested and found to comply with the limits of the Class A digital device, pursuant to Part 1 5 of the FCC rules . Thes e limits are desi gned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment[...]
-
Page 6
Declaration of Conformity Manufacturer’s Name: RAD Data Communications Ltd. Manufacturer’s Address: 12 Hanechoshet St. Tel Aviv 69710 Israel declares that the product: Product Name: AMC-101 Conforms to the following standard(s) or other normative document(s): EMC: EN 55022 (1994) Limits and methods of measurement of radio disturbance characteri[...]
-
Page 7
AMC-101 Installation and Operation Manual i Contents CHAPTER 1 – INTRODUC TION 1.1 General .................................................................................................................... ......................... 1-1 Retimed Mo dules .............................................................................................[...]
-
Page 8
Contents ii AMC-101 Installation and Operation Manual SM/ST/13LH/ R Modul e ............................................................................................................ ........... 2-15 SM/FC/13LH/ R Mod ule............................................................................................................ ........... 2-16 S[...]
-
Page 9
Contents AMC-101 Installation and Operation Manual iii List of Figures Figure 1-1 Dissimilar Devic e Con nectivity .................................................................................... .............. 1-3 Figure 1-2 Dual Simila r Device Co nnec tivity .................................................................................. .[...]
-
Page 10
List of Tables iv AMC-101 Installation and Operation Manual Figure 2-36 10BT/ B Mod ule Fron t Panel........................................................................................ ........... 2-35 Figure 3-1 AMC -101 Front Pane l ............................................................................................... ...............[...]
-
Page 11
General 1-1 Chapter 1 Introduction 1.1 General The AMC-101, a Universal Converter and Repeater, provides retimed or transparent conversion of optical and electrical signals for ATM, FDDI, Fast Ethernet and other protocols at data rates up to 155 Mbps. The modularity of the AMC-101 interfaces enables field-changeable conversion between any two media[...]
-
Page 12
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-2 Features 1.2 Features Modular Media Converter and Repeater, Media types supported: • Single Mode Fiber • Multimode Fiber • STP • UTP • Coax Retimed media conversion for 51 Mbps, 100 Mbps and 155 Mbps. Transparent media conversion up to 155 Mbps. In retimed mode can b[...]
-
Page 13
AMC-101 Installation & Operation Manual Chapter 1 - Introduction General Applications 1-3 1.3 General Applications A single AMC-101 is used to connect two devices operating with different fiber or electrical interfaces (see Figure 1-1 ). AT M S t a t i o n UTP Cat 5 1300 nm Singl e M ode Fi ber 155 Mbp s AMC-101 AT M S w i t c h Figure 1-1 Diss[...]
-
Page 14
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-4 General Applications A single AMC-101 in WRAP mode can be used for double conversion between single mode and multimode fiber for a dual attached FDDI station or concentrator (see Figure 1-3 ). Figure 1-3 WRAP: Dual Single Mode (SM) to Multimode (MM) Conversion A single AMC-101[...]
-
Page 15
AMC-101 Installation & Operation Manual Chapter 1 - Introduction General Applications 1-5 The FDDI applies scrambling to data when operating over UTP, but not doing so when operating over fiber. Because of this, AMC-101 can only work in pairs for extending FDDI connections over fiber (see Figure 1-5 ). FDDI FDDI UTP Cat 5 UTP Cat 5 Fiber AMC-10[...]
-
Page 16
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-6 Fast Ethernet Applications 1.4 Fast Ethernet Applications • Point to Point Link using a pair of Fiber Optic Cables running in HD (Half Duplex) 100-BaseFX: Problem: In a point to point application, in HD, the maximum range is limited to 412m . Fib er Optic Link Fib er Optic L[...]
-
Page 17
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Fast Ethernet Applications 1-7 • Repeater based LAN Link using standard UTP at HD (Half Duplex). Problem: Range is limited to 100m from the repeater. Repeat er UTP UTP Up to 100m Up to 100m Fast Eth ernet S tati on Fast Eth ernet S tati on (Lapto p) Figure 1-8 Repeater Half Dupl[...]
-
Page 18
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-8 Fast Ethernet Applications • Extension of a point to point FD (Full Duplex) Fast Ethernet connection: Problem: The distance between two FD stations running on UTP needs to be extended. UTP Up t o 100m FD Fas t Eth ernet Stat ion FD Fas t Eth ernet S tati on Figure 1-10 Point[...]
-
Page 19
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-9 • Extension of a Switched Based Fast Ethernet LAN (FD - Full Duplex) Problem: The range of a FD Fast Ethernet LAN running on UTP has to be extended. IBM Printer FD Fast E t herne t Switch UTP UTP UTP Up to 100m Up to 100m Up to 100m Fast Eth ernet S tati on Fa[...]
-
Page 20
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-10 Specifications 1.5 Specifications Data Rate Up to 155 Mbps Indicators POWER (PWR) ON when unit is powered FAULT (FLT) BLINKS when card configur ation is wrong WRAP ON when th e two interfaces a re wrapped SIG ON when rece ived signal from Rx is valid BLINKS when the PLL is ou[...]
-
Page 21
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-11 Table 1-1 Optical Module Characteristics Module Name Protocols Supported Fiber Type (Wavelength) Connector Type Typical Distance Dynamic Range Optical Power (Typical) Sensitivity MM/ST/85* Token Ring, Ethernet only 62.5/125 (850 nm) ST 2 Km / 1.2 mile 18 dB -18[...]
-
Page 22
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-12 Specifications Table 1-1 Optical Module Characteristics (Cont.) Module Name Protocols Supported Fiber Type (Wavelength) Connector Type Typical Distance Dynamic Range Optical Power (Typical) Sensitivity SM/FC/13LH*** (LASER) TAXI, FDDI, Fast Ethernet STS-3c/STM-1, STS-1 9/125 [...]
-
Page 23
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-13 Table 1-2 Electrical Module Characteristics Module Name Protocols Supported Cable Type Connector Type Range Impedance (Ohms) UTP/155* STS-3c UTP Cat 5 Shielded RJ-45 100 m 100 STP/155* STS-3c STP Type 1 DB-9 100 m 150 UTP/100* FDDI, UTP Cat 5 Shielded RJ-45 100[...]
-
Page 24
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-14 Specifications[...]
-
Page 25
Site Requirements 2-1 Chapter 2 Installation & Setup 2.1 Unpacking Before Unpacking Inspect the equipment container before unpacking. Note and report evidence of damage immediately. Unpacking Procedure • Place the container on a clean flat surface . Cut all st raps and ope n or remove top. • Remove the unit carefully and place it securely o[...]
-
Page 26
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-2 Site Requirements Figure 2-1 AMC-101 Rear Panel AC Version Figure 2-2 AMC-101 Rear Panel DC Version Installation of a Single Unit Rack adapter components for installing a single unit include one short bracket and one long bracket. Each bracket is fastened to the si[...]
-
Page 27
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup Site Requirements 2-3 Installation of Two Units Rack adapter components for installing two units include two long side rails (one for each unit) which slide one into the other fastening the two units together, and two short side brackets which hold the two units in the[...]
-
Page 28
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-4 AMC-101 Modules Figure 2-5 Installation of Two Units (b) 2.3 Cable Connections AC Power Connection AC power should be supplied to AMC-101 through a 1.5m (5 ft) standard power cord terminated by a grounded 3-wire plug. Warning When applying AC power, first connect t[...]
-
Page 29
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-5 2.4 AMC-101 Modules The upper part of t he module front panel i s AMC-R for a R eti med Timing mode; the lower part is AMC-T for a Transparent Timing mode. In bot h panels, the module name is labeled at panel’s bottom. MM/SC/13/R Module Figure 2-6[...]
-
Page 30
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-6 AMC-101 Modules MM/SC/13/T Module Figure 2-7 MM/SC/13/T Module Front Panel Wavelength: 1300 nm Connector: SC Used with: Multimode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optical ou[...]
-
Page 31
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-7 MM/ST/13/R Module Figure 2-8 MM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Multimode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical ou[...]
-
Page 32
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-8 AMC-101 Modules MM/ST/13/T Module Figure 2-9 MM/ST/13/T Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Multimode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optical ou[...]
-
Page 33
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-9 SM/ST/13/R Module Figure 2-10 SM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Optical[...]
-
Page 34
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-10 AMC-101 Modules SM/ST/13/T Module Figure 2-11 SM/ST/13/T Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optica[...]
-
Page 35
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-11 SM/FC/13/T Module Figure 2-12 SM/FC/13/T Module Front Panel Wavelength: 1300 nm Connector: FC Used with: Single mode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Optica[...]
-
Page 36
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-12 AMC-101 Modules SM/ST/13L/R Module Figure 2-13 SM/ST/13L/R Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Opti[...]
-
Page 37
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-13 SM/ST/13L/T Module Figure 2-14 SM/ST/13L/T Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: Any two level optical protocols up to 155 Mbps Timing mode: Transparent Coding method: 4B/5B, NRZ Opti[...]
-
Page 38
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-14 AMC-101 Modules SM/SC/13L/R Module Figure 2-15 SM/SC/13L/R Module Front Panel Wavelength: 1300 nm Connector: SC Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Opti[...]
-
Page 39
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-15 SM/ST/13LH/R Module Figure 2-16 SM/ST/13LH/R Module Front Panel Wavelength: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Op[...]
-
Page 40
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-16 AMC-101 Modules SM/FC/13LH/R Module Figure 2-17 SM/FC/13LH/R Module Front Panel Wavelength: 1300 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Op[...]
-
Page 41
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-17 SM/ST/15L/R Module Figure 2-18 SM/ST/15L/R Module Front Panel Wavelength: 1550 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Opti[...]
-
Page 42
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-18 AMC-101 Modules SM/ST/15LH/R Module Figure 2-19 SM/ST/15LH/R Module Front Panel Wavelength: 1550 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c; STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Op[...]
-
Page 43
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-19 SM/FC/15LH/R Module Figure 2-20 SM/FC/15LH/R Module Front Panel Wavelength: 1550 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Coding method: 4B/5B, NRZ Op[...]
-
Page 44
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-20 AMC-101 Modules MM/ST/85/T Module Figure 2-21 MM/ST/85/T Module Front Panel Wavelength: 850 nm Connector: ST Used with: Multimode fiber Protocols supported: Token Ring, Ethernet only Timing mode: Transparent Coding method: 4B/5B, NRZ, Manchester Optical output int[...]
-
Page 45
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-21 SF1/ST/R Module Figure 2-22 SF1/ST/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 1550 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical [...]
-
Page 46
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-22 AMC-101 Modules SF2/ST/R Module Figure 2-23 SF2/ST/R Module Front Panel Wavelength: Transmit: 1550 nm; Receice: 1300 nm Connector: ST Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical [...]
-
Page 47
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-23 SF1/FC/R Module Figure 2-24 SF1/FC/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 1550 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical [...]
-
Page 48
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-24 AMC-101 Modules SF2/FC/R Module Figure 2-25 SF2/FC/R Module Front Panel Wavelength: Transmit: 1550 nm; Receive: 1300 nm Connector: FC Used with: Single mode fiber Protocols supported: STS-3c, STM-1, STS-1, FDDI, TAXI and Fast Ethernet Timing mode: Retimed Optical [...]
-
Page 49
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-25 CX/BNC/155/R Module Figure 2-26 CX/BNC/155/R Module Front Panel Connector: BNC Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.7 dB at 78 M Hz accord ing t o square root of frequency law Impedance[...]
-
Page 50
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-26 AMC-101 Modules CX/DIN/155/R Module Figure 2-27 CX/DIN/155/R Module Front Panel Connector: 1.6/5.6 Coax Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.7 dB at 78 MHz ac cording to square root of fre quency law; [...]
-
Page 51
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-27 STP/155/R Module Figure 2-28 STP/155/R Module Front Panel Connector: DB-9 Used with: STP type 1 cable Protocols supported: STS-3c Timing mode: Retimed Coding method: NRZ Range: 100 m Impedance: 150 Ω Table 2-1 STP/155/R Pinout Pinout Pin 1 Rx+ Pi[...]
-
Page 52
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-28 AMC-101 Modules STP/155/T Module Figure 2-29 STP/155/T Module Front Panel Connector: DB-9 Used with: STP type 1 cable Protocols supported: STS-3c Timing mode: Transparent Coding method: NRZ Range: 50 m Impedance: 150 Ω Table 2-2 STP/155/T Pinout Pinout Pin 1 Rx+[...]
-
Page 53
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-29 UTP/155/R Module Figure 2-30 UTP/155/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: STS-3c Timing mode: Retimed Coding method: NRZ Range: 100 m Impedance: 100 Ω Table 2-3 UTP/155/R Pinout Pinout Pin 1 Tx+[...]
-
Page 54
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-30 AMC-101 Modules UTP/155/T Module Figure 2-31 UTP/155/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: STS-3c Timing mode: Transparent Coding method: NRZ Range: 50 m Impedance: 100 Ω Table 2-4 UTP/155/T Pinout Pinout Pin 1 [...]
-
Page 55
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-31 UTP/100/R Module Figure 2-32 UTP/100/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: FDDI Timing mode: Retimed Coding method: NRZ Range: 100 m Impedance: 100 Ω Table 2-5 UTP/100/R Pinout Pinout Pin 1 Tx+ P[...]
-
Page 56
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-32 AMC-101 Modules UTP/100/T Module Figure 2-33 UTP/100/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: FDDI Timing mode: Transparent Coding method: NRZ Range: 50 m Impedance: 100 Ω Table 2-6 UTP/100/T Pinout Pinout Pin 1 Tx[...]
-
Page 57
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-33 100BT/B Module AMC-B 100BTX TX RX LINK COLL Figure 2-34 100BT/B Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: Fast Ethernet (100 Base TX): Half Duplex on UTP side and Full Duplex on second module side Timing[...]
-
Page 58
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-34 AMC-101 Modules 100BT/R Module AMC-R 100BTX TX RX LINK Figure 2-35 100BT/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: Fast Ethernet (100 Base TX): Half or Full Duplex (HDX to HDX or FDX to FDX) Timing mode: Retimed Codin[...]
-
Page 59
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-35 10BT/B Module AMC-B 10BT TX RX LINK COLL Figure 2-36 10BT/B Module Front Panel Connector: Shielded RJ-45 Used with: UTP Cat 5 Protocols supported: Ethernet (10Base-T): Half or Full Duplex Timing mode: Retimed Range: 100 m Impedance: 100 Ω Table 2[...]
-
Page 60
Controls and Indicators 3-1 Chapter 3 Operation 3.1 Controls and Indicators All controls and indicators are located on the front panel of AMC-101. PWR FL T WRAP OTHER 155 100 51 AMC-R AM C-R SIG SIG TX R X STP /155 ST/ SM 1300 A B C 1 2 Figure 3-1 AMC-101 Front Panel Table 3-1 AMC-101 Front Panel Indicators Indicators Description POWER: ON when uni[...]
-
Page 61
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-2 Controls and Indicators Po wer Su pp ly AC DB-9 Conne cto r (AL ARM ) JP 2 JP 1 AMC-RELA Y (AL ARM ) Card JP 1 JP 4 JP 2 GN D JP 6 JP 7 VC C ERR-CFG IDLE- EN AMC-101 Module AM C-101 Module LEDs C ard Figure 3-2 Jumper Locations and Functions Table 3-3 Functions and Settings Jumpe[...]
-
Page 62
AMC-101 Installation & Operation Manual Chapter 3 - Operation Dry Contact Circuit and Connector for Alarms 3-3 3.2 Cable Connections Grounding DC adapter Connection. Note In order to protect the AMC-1 from electrostatic discharge (ESD), use a DC adapter where the (-) DC pole is connected to the protective earth. 3.3 Dry Contact Circuit and Conn[...]
-
Page 63
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-4 Turning on the AMC-101 Example: For the RED ALARM the common input (COM) pin is 9. If there is no power failure, it connects to pin 4 (OK). If there is a failure, pin 9 connects to pin 5 (FAIL). 3.4 Turning on the AMC-101 Connect the AC cable of AMC-101 to the mains outlet. The P[...]
-
Page 64
AMC-101 Installation & Operation Manual Chapter 3 - Operation Turning on the AMC-101 3-5 PWR LED FL T LED WRA P LE D WRAP Butto n 51 100 155 Ot her RA TE Switc h Cont ro l Logi c Rela y 1 Dry Co n ta ct Relay 2 Relay 3 Id le Id le Modul e Co nnec to r REF Status Status REF Fiber/Copp er Tr a ns mi t t e r Fiber/Copp er Tr a ns mi t t e r Ret im[...]
-
Page 65
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-6 Troubleshooting Procedures 3.5 Normal Operation Once powered on, the POWER indicator should light up and the FLT should be turned off. If the FLT indicator blinks, a configuration error exists: the combination of the card types and the selected data rate is illegal. Each AMC-101 [...]