RAD Data comm ASM-60 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of RAD Data comm ASM-60, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of RAD Data comm ASM-60 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of RAD Data comm ASM-60. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of RAD Data comm ASM-60 should contain:
- informations concerning technical data of RAD Data comm ASM-60
- name of the manufacturer and a year of construction of the RAD Data comm ASM-60 item
- rules of operation, control and maintenance of the RAD Data comm ASM-60 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of RAD Data comm ASM-60 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of RAD Data comm ASM-60, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the RAD Data comm service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of RAD Data comm ASM-60.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the RAD Data comm ASM-60 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ASM-60 10 Mbps VDSL-B ased Modem Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communication s. No part of this publicatio n may be repr oduced in any for m whatsoever w ithout p rior written appro val by RAD Data Commun ications. No representation or warranties for fitness for any purpose[...]

  • Page 2

    [...]

  • Page 3

    Warranty This RAD produ ct is warranted against defects in material and workm anship for a period of one y ear from date o f shipment. Dur ing the war ranty per iod, RA D will, at its op tion, either repair o r replac e products which prove to be defecti ve. For warranty servi ce or repair, this produ ct must be returned to a service fac ility desi[...]

  • Page 4

    Safety Warnings The excl amation poin t within a trian gle is intend ed to warn the operato r or service pers onnel of operation and mai ntenance factors relati ng to the product and its operati ng environment which could pos e a safety hazard. Alwa ys observe stan dard safety pre caution s during in stallat ion, op eration and maint enanc e of th [...]

  • Page 5

    Installing ASM-60 1 Quick Start Guide Installation of ASM -60 should be carried out only by an experie nced technician. If you ar e famil iar with ASM -60, use this gu ide to prep are th e uni ts for opera tion. 1. Installing ASM-60 Set ting the Inte rnal Sw itche s Perform th e interna l settin gs as fol lows: 1. Discon nect the po wer co rd f rom[...]

  • Page 6

    Quick Start G uide ASM-60 Installat ion and Oper ation Manu al 2 Configuring ASM-60 2. Operating ASM-60 Normal Indica tions The tab le bel ow show s th e corre ct sta tus of the in dicato rs a fe w secon ds af ter power-up. Indic ator Statu s PWR ON TD Depend s on DTE dat a transmissio n. RD Depend s on DTE dat a transmissio n. RTS Depend s on DTE [...]

  • Page 7

    ASM-60 Installa tion and Op eration Manual i Contents Chapter 1 . Introdu ction 1.1 Overview .......................................................................................................... 1-1 General ................................................................................................................... 1-1 Versions..........[...]

  • Page 8

    Table of Contents ii ASM-60 Installat ion and Oper ation Manu al Appendix A. IR-ETH Interface M odule Appendix B. IR- ETH/QH Interface Module Appendix C. IR -IP Interface M odule List of Figures 1-1. Typical ASM- 60 Application ...................................................................................... 1-1 1-2. 3D View of ASM- 60 .......[...]

  • Page 9

    Overview 1-1 Chapter 1 Introduction 1.1 Overvi ew General ASM-60 is a VDSL (Very High-bitrate Digital Subscriber Line) modem handling high data rates. ASM-60 supports HSSI DTE interface, and several Ethernet inte rface modules, wh ich allow LAN-t o-LAN connectivit y using VDSL tec hnology. Working in full duplex ove r 4-wire link, t he modem can be[...]

  • Page 10

    Chap ter 1 Introd uction ASM-60 Installat ion and Oper ation Manu al 1-2 Overview Table 1-1. Ty pical ASM-60 R anges Data R ate 24 AWG (Mbps) km miles 4.096 2.0 1.2 6.144 2.0 1.2 10.24 1.8 1.1 DTE Interface The ASM -60 D TE inter fac e suppo rts th e foll owing in terfac es: • HSSI • IR-ETH module with built -in Ethernet bridge • IR-ETH/QH mo[...]

  • Page 11

    ASM-60 Installat ion and Oper ation Manu al Chapter 1 Int roduct ion Physical Descript ion 1-3 1.2 Physical Description Fig ure 1-2 shows a 3D view of the ASM-60 st andalone modem. Figure 1-2. 3D Vie w of ASM-60 The front panel inc ludes nine LEDs, which display the status of power, data flow, control si gnals and provide di agnostics. The front pa[...]

  • Page 12

    Chap ter 1 Introd uction ASM-60 Installat ion and Oper ation Manu al 1-4 Functional Description 1.3 Functional Description This section provides a fu nctional description ( Figure 1-3 ) of ASM-60 in the form of block di agrams. CPU Addi tional Decoder La tch /B uffe r D8-D15 VDSL Framer DTE Interf ace TxD, Rx D IN T , E XT Clock Data, Clock Data, C[...]

  • Page 13

    ASM-60 Installat ion and Oper ation Manu al Chapter 1 Int roduct ion Technical Sp ecifications 1-5 1.4 Te chnic al Spec ificatio ns Line Interface Protoc ol Very High-bi t-ra te Digi tal Subscr iber Lin e (VDS L) Type 4-wire, u ncon dition ed de dicat ed line s (twist ed pa ir), Cat.3 and Cat .5, 19 AWG to 26 A WG Line Co ding QAM Rang e See Table [...]

  • Page 14

    Chap ter 1 Introd uction ASM-60 Installat ion and Oper ation Manu al 1-6 Technical Sp ecifications Indicators PWR (green) Power RTS ( yello w) Reque st to S end TD (yel low) Transmit Data RD (yel low) Receive D ata DCD (yell ow) Data Carrier De tect TST (red) Test ALM (red) Alarm SYNC A (green /red) Synchronization li ne A SYNC B (green /red) Synch[...]

  • Page 15

    Site Requir emen ts and Prer equis ites 2- 1 Chapter 2 Installation and Setup This chapter de scribes installation and s etup procedure s for the stand alone ASM-60 modem. ASM- 60 is delivered completely assembled. It is designe d for table top or 19-inch rack inst allation. After ins tallin g the un it: • Refer to Chapte r 3 for the operatin g i[...]

  • Page 16

    Chap ter 2 Insta llati on and Setup ASM-60 Installat ion and Oper ation Manu al 2-2 Installation and Setup 2.2 Package Contents The ASM -60 p ackag e incl udes th e fol lowin g items : • One ASM- 60 unit • ASM-60 Inst allation and Operat ion Manual • AC power cord. 2.3 Installation and Setup The ASM-60 standal one un it is design ed for des k[...]

  • Page 17

    ASM-60 Installat ion and Operat ion Manu al Chapter 2 In stallat ion and Se tup Install ation and Setup 2-3 Opening the ASM-60 Case ➤ To open the ASM-60 case: 1. Discon nect the po wer co rd f rom th e pow er sou rce. 2. Slid e the blue side pane l forward to detach it from the case. 3. Unscr ew the two screws l oca ted on the b otto m pan el at [...]

  • Page 18

    Chap ter 2 Insta llati on and Setup ASM-60 Installat ion and Oper ation Manu al 2-4 Installation and Setup Connecting the DTE The ASM -60 D TE int erfac e prov ides in terfac e for inp ut/outp ut data , cl ock referen ce an d con tro l sign als b etween the m odem an d the DT E. Th e ASM -60 D TE interface c an be either HSSI interface mod ule, ter[...]

  • Page 19

    ASM-60 Installat ion and Operat ion Manu al Chapter 2 In stallat ion and Se tup Install ation and Setup 2-5 Co nnect ing the Pow er Before switching on this unit and connecting any other cable, the protec tive earth terminals of this unit must be connected to the protective ground conductor of the power co rd. If you are using an extension cord (po[...]

  • Page 20

    Chap ter 2 Insta llati on and Setup ASM-60 Installat ion and Oper ation Manu al 2-6 Installation and Setup[...]

  • Page 21

    Front Panel Indicators 3-1 Chapter 3 Operation This chapter provid es the de scription of the A SM-60 front-pa nel indicators, an d details t he modem's operating procedures (t urn-on, front-pane l indications, performance monit oring and turn-off). Installati on procedures given in Chapter 2 must be c omp leted a nd check ed b efo re attemp t[...]

  • Page 22

    Chapter 3 Oper ation ASM-60 Installat ion and Oper ation Manu al 3-2 Operating ASM-60 Table 3-1. ASM- 60 LED Indi cators ( Cont.) Name Function SYNC A (red/green) ON (red ) – Data link A is not synchronized with the remote modem. ON (green) – Data link A is synchron ized with the remo te modem. SYNC B (red/green) ON (red) – Data link B is not[...]

  • Page 23

    13-Nov-01 18:46 Preparing for the Control Session 4-1 Chapter 4 Management from a Terminal The config uration of ASM-60 is pe rformed vi a menu-driven embedded so ftware using a stand ard ASCII terminal or a PC running a terminal e mulation application connecte d to the front pane l CONTROL DCE port . This terminal c an be used for perfor ming the [...]

  • Page 24

    Chapter 4 Management from a Terminal ASM-60 Installat ion and Oper ation Manu al 4-2 Na vigating the M anagement Menus Table 4-1 . Control Port C ontrol S ignal s Control Line Interface Type DCE DTE CTS Out Not Used DCD Out Out DSR Out Out DTR In In RI Not Used In RTS In In Data Terminal Ready (DTR) When co nne cte d and tur ned o n, th e term inal[...]

  • Page 25

    ASM-60 Installation and Operation Manual Chapter 4 Management from a Terminal Starting the Control Session 4-3 Term ina l Man agement Menu s Fig ure 4-1 show s a map of the management menus in the ASM-60 embedded software. The second leve l menus (Configuration, Display, Reset) are described in its own section in this chapter. The Alarms, Log File,[...]

  • Page 26

    Chapter 4 Management from a Terminal ASM-60 Installat ion and Oper ation Manu al 4-4 Configuring ASM-60 ASM-60/CO Main Menu 1. Configuration 2. Display 3. Test 4. Reset 5. Debug > ESC - previous menu ; ! - main menu ; & - exit terminal ------------------------------------------------------- Figure 4-2. Main Me nu At the bottom o f the termin[...]

  • Page 27

    ASM-60 Installation and Operation Manual Chapter 4 Management from a Terminal Displaying the ASM-60 System Information 4-5 Data Rate (current value) Enter the Devise Bit Rate 1. 4096 kbps 2. 6144 kbps 3. 10240 kbps > ESC - previous menu ; ! - main menu ; & - exit terminal ------------------------------------------------------- Figure 4-4. Da[...]

  • Page 28

    Chapter 4 Management from a Terminal ASM-60 Installat ion and Oper ation Manu al 4-6 Displaying the ASM-60 System Information Displaying the ASM -60 Status You can display t he current status of the local and remote ASM-60 mode ms. ➤ To display the ASM-60 stat us: • From the Display menu, type 1 . The Statu s scr een is displ ayed ( see Figure [...]

  • Page 29

    ASM-60 Installation and Operation Manual Chapter 4 Management from a Terminal Resetting ASM-60 4-7 4.6 Resetting ASM-60 You can perform res et of the main components of ASM-60, or reset t he modem to its factory set tings. ➤ To reset ASM-60: 1. From t he Main menu, type 4 . The Rese t menu appears ( Figure 4-7 ). 2. From t he Reset menu, choose o[...]

  • Page 30

    Chapter 4 Management from a Terminal ASM-60 Installat ion and Oper ation Manu al 4-8 Resetting ASM-60[...]

  • Page 31

    Error Detection 5-1 Chapter 5 Diagnostics This chapt er describe s the ASM-6 0 diagn osti c functio ns, which in clude: • Status indicat ions, alarms, power-up se lf-test • VDSL performance diagnostics • LED testing. 5.1 Error Detection This sect ion explains how to detect and fix errors and other problematic conditions in ASM-60. Power-Up S [...]

  • Page 32

    Chapter 5 Diagn ostics ASM-60 Installat ion and Oper ation Manu al 5-2 Error Detection Alarms DCD Failed > ESC - previous menu ; ! - main menu ; & - exit terminal ------------------------------------------------------- Figu re 5-1. Ala rms Scree n The di splay o f the Al arms screen incl udes o nly th e na me of th e alar m. Once th e ev ent[...]

  • Page 33

    ASM-60 Installat ion and Operat ion Manu al Chapter 5 Diag nost ics Displaying the VDSL Performance Diagnostics 5-3 Table 5-1. ASM- 60 Alar ms Number Terminal Message Description Severity 1 FPGA DOWNLOAD FAILED Failure to downloa d programming to the ASM-6 0 FPG A microp rocess or Major 2 SELF T EST ERROR A problem h as been detected during the dev[...]

  • Page 34

    Chapter 5 Diagn ostics ASM-60 Installat ion and Oper ation Manu al 5-4 Displaying the VDSL Performance Diagnostics VDSL Performance Line A Lock Status: SYNC Line A Avg. Snr.: 34 Line A BER pre FEC: 0.000E+00 Line A BER after FEC: 0.000E+00 Line B Lock Status: SYNC Line B Avg. Snr.: 34 Line B BER pre FEC: 0.000E+00 Line B BER after FEC: 0.000E+00 &g[...]

  • Page 35

    ASM-60 Installat ion and Operat ion Manu al Chapter 5 Diag nost ics Running the Diagnostic Tests 5-5 5.3 Running t he D iagnostic Tests Running the LEDs Test The ASM -60 m odem ca n p erfo rm the f ront-p an el indica tors test to v erif y tha t the unit LEDs are fu nctioning properly. ➤ To run the LEDs tes t: 1. From t he Main menu, type 3 . The[...]

  • Page 36

    Chapter 5 Diagn ostics ASM-60 Installat ion and Oper ation Manu al 5-6 Running the Diagnostic Tests[...]

  • Page 37

    IR-ETH Connector Options A-1 Appendix A IR-ETH Interface Module IR-ETH is an interf ace mo du le for RAD mod ems, u sed f or con vertin g th e Eth ern et (10 BaseT o r 10 Base2 ) ele ctrica l lev els to the m odem TTL levels . It al so con vert s th e Ethernet prot ocol to HDLC to enable long-distance trans mission and avoid the Ethernet coll ision[...]

  • Page 38

    Appendix A IR-E TH Interfac e Module ASM-60 Installat ion and Oper ation Manu al A-2 Technical Specif ications A-1 2 4 5-B : FOR CONT INUED TYPE AND RATING OF FUSE. FIRE, REPLACE ONLY WITH SA ME PR OTE CT ION AGAI N ST R IS K OF CAUT IO N 100-230 VAC 0.250A T 250V 10BASE-2 TX COLL RX LINE Figure A-3. Rear Panel of ASM-60 with IR -ETH Module (BNC Co[...]

  • Page 39

    ASM-60 Installat ion and Operat ion Manu al Appen dix A IR-ETH Inter face Module Installation and Oper ation A-3 A. 3 Inst all ation an d Opera tio n Figure A-4 and Figure A-5 show the Ethe rnet bridge layout, the loc ations of the DIP switch es, and the r ear p anel co mpon ents f or the UT P an d the B NC ver sions , respectively. Figure A-4. IR-[...]

  • Page 40

    Appendix A IR-E TH Interfac e Module ASM-60 Installat ion and Oper ation Manu al A-4 Installation and Operation DIP Swit ch Setti ngs Table A-2 describes fu nction s and def ault se tting s of the DI P swit ch SW-1 s ectio ns. Table A -2. DI P Switc h Sett ings Section Number Name Description Default Setting 1 SQ/FD ON – Full-duplex operati on OF[...]

  • Page 41

    IR-ETH/QH Connector B-1 Appendix B IR-ETH/QH Interface Module B.1 Introduct ion The IR- ETH/Q H int erface modu le incl udes a high p er form ance s elf-lea rnin g Fast Ethernet brid ge, which is connected to the LAN via a single 10BaseT or 100BaseT port, operating in f ull dup lex and providing of fer simple and cos t-effectiv e interconnec tion b[...]

  • Page 42

    Appendix B IR- ETH/QH Interface Mo dule ASM-60 Installat ion and Oper ation Manu al B-2 Technical Specifications Table B -1. RJ-45 Connecto r Pinout Pin Si gnal Function 1 RD (+) Re ceive Data (positive) 2 RD (-) Rec eive Data (negative) 3 TD (+) Transmit Data (positive) 6 TD (-) Transmit Data (negative) B.3 Te chn ical S pecif icatio ns Bridge LAN[...]

  • Page 43

    ASM-60 Installat ion and Operat ion Manu al Appendix B IR- ETH/QH Interf ace Module Installation and Operat ion B-3 B.4 I nsta lla tion and Opera ti on Figure B-3 sho ws l ocat ion of the conf igura tion DI P swit ch on the mo dule’s bo ard. S1 ON 8 7654321 Figure B-3. DIP Swi tch Location Setti ng the D IP Swi tch Configu re the IR-ETH /QH modul[...]

  • Page 44

    Appendix B IR- ETH/QH Interface Mo dule ASM-60 Installat ion and Oper ation Manu al B-4 Installation and Operation LED Indica tors Table B- 3 lists the IR-ETH/QH rear-panel LED indicators and describes their functions . Table B-3 . IR-ET H/QH L ED I ndicat ors LED Name Color Description Location LINK Green ON – LAN is c onnected to the IR -ETH/QH[...]

  • Page 45

    Introduc tion C-1 Appendix C IR-IP Interface Module C.1 Introduction Overview IR-IP is a high-performance, mi niature IP rout er based on R AD's unique IP router chip, the Chip Router. IR-IP wor ks by takin g each Eth ernet f ram e from the L AN and deter mining whet her the IP pa ck et is d estine d f or the I P net o n th e Ether net LA N. I[...]

  • Page 46

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-2 Physical Description Application Figure C-1 shows a typ ical ap plica tion of the ASM-6 0 modem equip ped wi th th e IR-IP i nterface module. ASM-60 wit h IR-IP ASM-60 wit h HSSI Interf ace Router Figure C-1. Typical Application of ASM-60 wi th IR-IP C.2 Te chnic al [...]

  • Page 47

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Physical D escription C- 3 IR-IP LEDs IR-IP contain s thr ee LEDs , which indi cate th e mo dul e activi ty. Table C-1 lists th e LEDs functi ons. Table C-1. IR-IP LE Ds Functio ns Name Type Function INT Green LED ON – LAN in tegrity is established . ACT Yellow LED [...]

  • Page 48

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-4 IR-IP Management Subsystem, General C.4 IR-IP Management Su bsystem, Genera l Introduc tion The IR-IP interface module management subsystem supports the following functions : • Preliminary configu ration • Configuration of manage ment acces s parameters • Advan[...]

  • Page 49

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Performing Preliminary Configuration C-5 Default IP C ommunicatio n Parameters The d efaul t IP com mun ica tion p aram eters o f th e inte rfa ce modu le ar e: • The default IP addres s of the IR- IP Ethernet port is 192.168.20 5.1, and t he default IP subnet mas k[...]

  • Page 50

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-6 Performing Pre liminary Configuration Co nnect ing the Teln et Host Before starting the management and configuration activities , it is necessary to establ ish I P commun ica tion b etween yo ur Tel net h ost a nd the I R-I P interf ace module. For this purpose , it [...]

  • Page 51

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Performing Preliminary Configuration C-7 The IP a ddr ess is ac tual ly retr iev ed from the AR P fra mes s ent du ring p inging to loca te the ping destinatio n, not f rom the ping frames. To ensure that the proc ess is correctly performed, it is rec ommended to chec[...]

  • Page 52

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-8 Performing Pre liminary Configuration After cha ng ing the des tina tion IP a ddr ess of th e Teln et ho st, it i s re comm ende d to turn ASM-60 off for a fe w seconds and then back on, before co ntinuing the configuration of the IP router in accor dance with the Qu[...]

  • Page 53

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule IR-IP Managem ent Utilit y C-9 C.6 IR- IP Mana gement Util ity General Op erating Proced ures The IR-IP interface module is managed via a simple, menu-driven ut ility that uses a basic terminal user interf ace. A typ ical screen is shown in Figure C-4 . As seen in Fig[...]

  • Page 54

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-10 Quick Setup Menu To end th e util ity, p ress <Esc> when the Main menu is displayed. This will also end the Tel net sessio n. Menu Structur e of Managem ent Utility Figure C-5 shows th e men u str uctur e of th e IR-I P ma nagemen t util ity. Main Menu 1. Quic[...]

  • Page 55

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Quick Setup Menu C-11 IR_IP <IR-IP> S/W Ver. 1.00 31/IR (date) Quick Setup ===================================================================== 1. LAN IP Address :192.168.100.001 2. LAN IP Mask :255.255.255.000 3. WAN IP Address (empty for unnumbered) :........[...]

  • Page 56

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-12 Manage ment Access Me nu Default Gateway Operation without Default Gateway The IP in terf ace mo dule is in tende d to en abl e the ex tens ion o f LANs th roug h the ASM-60 VDSL lin k. Therefore, its default rou ting operation is d ifferent from the default rout in[...]

  • Page 57

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Advanced Setup Menu C-13 ➤ To access the Management Access menu: • From the Main menu, t ype 2 . The Manag ement Ac cess menu appear s ( Figure C-8 ). IR_IP <IR-IP> S/W Ver. 1.00 31/IR (date) Quick Setup Management Access ====================================[...]

  • Page 58

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-14 Advanced Setup Menu ➤ To access the Advanced Setup menu: • From the Main menu, press 3 . The Advanced Setup menu appears ( Figure C-9 ). IR_IP <IR-IP> S/W Ver. 1.00 31/IR (date) Quick Setup Management Access Advanced Setup =================================[...]

  • Page 59

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Advanced Setup Menu C-15 Contact Person Sele ct this p aram eter to en ter the n ame of th e pers on to be con tact ed with m att ers pertain ing to this equipm ent un it. System Location Select th is pa rame ter to enter the p hysical loca tion of the d evice. Interf[...]

  • Page 60

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-16 Advanced Setup Menu The available se lections are: • 64 kbps • 128 kbps • 256 kbps • 512 kbps • 1024 kbps • Full (no rest riction on the rate). Since the IP route r buffers have a limited capacity (256 frames), it is recommended to sel ect th e WAN Th ro[...]

  • Page 61

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Advanced Setup Menu C-17 EIR Used to sp ecify th e ma ximu m amo unt of data, in bits, th at th e Fra me Rela y networ k will a ttempt to de liver du ring th e m easur ement in terv al. T he valu e of t his para meter is o btain ed fr om th e Fram e Rela y servi ce pr[...]

  • Page 62

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-18 Advanced Setup Menu Security Host/Gu est This o ption can be u sed to conf igure th e IP ro uter either a s a gu est un it, to b e auth enticated by another rou ter, or as a ho st unit, tha t authentica tes other router s. User Name To Send The nam e by which an IP [...]

  • Page 63

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Advanced Setup Menu C-19 Multicast I P Menu The Mul ticas t IP m enu is u sed to sp ecif y the I P multi cast f ram e forw arding para meter s, and to acc ess the sta tic mu ltica st gro ups’ tabl e. ➤ To access the Multicast IP menu: • From the Adv anc ed Setu [...]

  • Page 64

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-20 Device Control Menu Static Groups Select th is pa rame ter to acce ss the s tati c mul ticast gr ou ps tab le. Th e tabl e is us ed to specify the IP addresses for up to 10 IP multicast groups. You can add, change , or dele te ea ch en try in the tab le (s ee th e p[...]

  • Page 65

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Device Control Menu C-21 New Softwar e Download M enu IR-IP op era tes as a TFTP client, and ther efore i t is po ssible to upda te its sof tware by downloading new software from another compute r that operates as a TFTP server. The New Software Downl oad menu is use [...]

  • Page 66

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-22 Device Control Menu View Error Log Screen This item of th e Devi ce C ontro l sub menu is u sed to view th e err or lo g fil e. This file logs errors detecte d in IR-IP for debug and technical support purposes. Rese ts Me nu The Resets menu allows you to pe rform re[...]

  • Page 67

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule View Menu C-23 Reset WAN ➤ To reset the WAN inter face: • From the Resets me nu, type 3 . You wil l be p romp ted to c onfir m the re set op eratio n. Resett ing th e WAN in terfa ce caus es the WAN cont ro ller to be r estart ed. Th is results in rene gotiat ion [...]

  • Page 68

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-24 View Menu IR_IP <IR-IP> S/W Ver. 1.00 31/IR (date) VIEW CONFIGURATION ------------------ BOOT Version :1.06 18.03.1999 Device Name :IP router card System Location :The location of this device Contact Person :Name of contact Person MAC Address : 00-20-D2-16-3F-[...]

  • Page 69

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule View Menu C-25 IR_IP <IR-IP> S/W Ver. 1.00 31/IR (date) Multicast Groups Table ---------------------- Group IP Address Status Group IP Address Status Press any key for exit Figure C -22. Multic ast Gr oups Tabl e Scre en Statistics Scr een The Stat istic s scre [...]

  • Page 70

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-26 Diagnostic Tool (Ping Terminal) Menu IR_IP <IR-IP> S/W Ver. 1.00 31/IR (date) SYSTEM STATISTICS ----------------- Counter Name Val Counter Name Val WAN in Octets 83504 WAN Alignment Errors 0 WAN Out Octets 1950 WAN Aborted Frames 0 WAN Out Frames 1723 WAN Shor[...]

  • Page 71

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Diagnostic Tool (Ping Terminal) Menu C-27 Usi ng the Pi ng Funct ion The Ping o ptio n is us ed to confir m IP con nect ivity by pinging other IP hosts. Connectivit y is confirme d by rec eiving a reply from t he remote ( pinged) I P host. ➤ To ping a host: 1. From [...]

  • Page 72

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-28 Erasing IR-IP Sof tware C.13 Erasing User’s Co nfigurat ion The user -d efined co nfigu ra tion p aram eters ar e stor ed in the I P rout er card f las h memory . Aft er the u ser -def ined co nfigu ration par ameter s are eras ed, the I P ro uter card au toma tic[...]

  • Page 73

    ASM-60 Installat ion and Operat ion Manu al Appen dix C IR-I P Inter face M odule Erasing I R-IP Sof tware C-29 2. Set all the fou r sect ions o f IR-I P DIP s witch to O N. 3. Turn the ASM -60 o n and m onito r th e IP rou ter ER R in dicato r: it m ust tu rn o n and l ight s teadil y. 4. While the ER R indica tor is l it (within 15 seconds) , set[...]

  • Page 74

    Appendix C IR-I P Interface Module ASM-60 Installat ion and Oper ation Manu al C-30 Erasing IR-IP Sof tware[...]