Go to page of
Similar user manuals
-
Outdoor Shower
Redring Expressions 520M/520TS
12 pages 3.52 mb -
Outdoor Shower
Redring TMV3
2 pages 0.75 mb -
Outdoor Shower
Redring Selectronic Mixer Shower TMV3
2 pages 0.78 mb -
Outdoor Shower
Redring 600
12 pages 2.3 mb -
Outdoor Shower
Redring 620
12 pages 2.3 mb -
Outdoor Shower
Redring 520M/520TS
12 pages 3.36 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Redring 600, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Redring 600 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Redring 600. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Redring 600 should contain:
- informations concerning technical data of Redring 600
- name of the manufacturer and a year of construction of the Redring 600 item
- rules of operation, control and maintenance of the Redring 600 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Redring 600 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Redring 600, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Redring service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Redring 600.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Redring 600 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SHOWER HANDBOOK IMPORTANT: Please retain this booklet for future reference[...]
-
Page 2
CONTENTS Page How to use your shower …………… 2 How your shower works …………… 3 What to do if things go wrong …………… 5 Installation instructions ………….... 6 How to maintain your shower …………… 10 Guarantee …………… 12 How to use your shower 1. Ensure the electricity and water are turned on to the unit 2[...]
-
Page 3
Model 620 - Press button “C”. Th e electricity to the elements is then switched off, water will continue to flow for approximately 5 seconds before switching off. This reduces the temperature of the water in the unit. Switch the electricity off at the ceiling switch or local isolator. 10. Your shower is designed to stabilise temperature changes[...]
-
Page 4
throughout the year from 5 to 20 ° C. This means that in Wi nter, the flow rate will be less than in the Summer to achieve the same outlet temperature. In summer the ‘MED (medium)’ or ‘LOW’ power setti ng may give adequate hot water. The heaters are only switched on when sufficient water is flowing. This is done automatically with a switch[...]
-
Page 5
Check the spray plate is then free to rotate to give the three settings. In some winter conditions, when the incoming mains water is particularly cold it may be necessary to select the inner or outer spra y pattern only. This will ensure correct operation of the shower with a slightly lower water flow rate Note: After use it is normal for some wate[...]
-
Page 6
a) Water too HOT Water flow restricted by blockage in filter of solenoid valve. Switch o ff water and undo plastic nut on elbow, loosen br ass nut to swing elbow away from solenoid. Remove filter in solenoid with long nosed pliers and flush clean. b) Water too COLD Check circuit through thermal cut-out Check circuit through microswitch on the press[...]
-
Page 7
c) The handset must not be able to come into contact with any used water in the bath or basin. If it can, even after the hose has been retained by the hose retainer (see diagram 13) , then a vacuum breaker must be fitted. It should be noted that these devices are liable to minor leakage so they must be positioned so that any drips are not detriment[...]
-
Page 8
1. It is recommended that a WRAS (Water Regul ations Advisory Scheme) listed isolating valve is fitted between the rising main and the unit. This will allow the unit to be serviced or exchanged without having to turn off t he water at the mains stop valve. 2. The heater can be fed from a header tank provided this has a minimum head height of 10.5 m[...]
-
Page 9
You may be able to use 6mm² cable if Method 1 (clipped direct) is used. Remember to up-rate the cable if it runs in thermal insulation in a loft, or for a longer distance. 3. A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules. We recommend ceiling switches. 4. Cut back cable as in di[...]
-
Page 10
d) That the holes in the sp ray plate are not blocked. e) Water flow can be adjusted by knob B. 9. DEMONSTRATE OPERATION TO USER 10. LEAVE THESE INSTRUCTIONS WITH THE USER FOR FUTURE REFERENCE. How to maintain your shower It is recommended that the shower unit, riser rail, hose etc. can be cleaned using a soft cloth and that the use of an abrasive [...]
-
Page 11
Diagram 13 11[...]
-
Page 12
Full details of terms and conditions are available on request from: - APPLIED ENERGY PRODUCTS LTD. MORLEY WAY, PETERBOROUGH. PE2 9JJ. Tel +44 (0)1733 456789 Fax: +44 (0) 1733 310606 Website: www.redring.co.uk 555.2067.01A 12[...]