Go to page of
Similar user manuals
-
Fan
Regency Wraps LX
12 pages 0.29 mb -
Stove
Regency Wraps C33-LP3
28 pages 2.22 mb -
Stove
Regency Wraps U38-NG
24 pages 2.73 mb -
Stove
Regency Wraps F38-NG2
24 pages 1.84 mb -
Indoor Fireplace
Regency Wraps I2400M
20 pages 0.83 mb -
Indoor Fireplace
Regency Wraps Z2510L
24 pages 5 mb -
Stove
Regency Wraps U38-LP
24 pages 2.73 mb -
Indoor Fireplace
Regency Wraps P36-NG4
44 pages 3.36 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Regency Wraps U41-NG3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Regency Wraps U41-NG3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Regency Wraps U41-NG3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Regency Wraps U41-NG3 should contain:
- informations concerning technical data of Regency Wraps U41-NG3
- name of the manufacturer and a year of construction of the Regency Wraps U41-NG3 item
- rules of operation, control and maintenance of the Regency Wraps U41-NG3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Regency Wraps U41-NG3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Regency Wraps U41-NG3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Regency Wraps service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Regency Wraps U41-NG3.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Regency Wraps U41-NG3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
W ARNING: If the information in these instructions are not followed ex- actly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by [...]
-
Page 2
2 Regency U41-3 UL TIMA TE Gas Fireplace Insert Note: Oversize faceplate 44-1/4" x 31-1/8" Extra Oversize Faceplate 50-1/4" x 35-1/8" TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Insert by FIREPLACE PRODUCTS IN- TERNA TIONAL L TD. The Regency UL TIMA TE Gas Fireplace Series of hand crafted appli[...]
-
Page 3
3 Regency U41-3 UL TIMA TE Gas Fireplace Insert T ABLE OF CONTENTS REGENCY UL TIMA TE GAS FIREPLACE INSERT SAFETY LABEL Safety Labels ................................................... 4 REQUIREMENTS MA Code - CO Detector (for state of Massachusetts only) ......................... 5 INST ALLA TION REQUIREMENTS For your safety .....................[...]
-
Page 4
4 Regency U41-3 UL TIMA TE Gas Fireplace Insert This is a copy of the label that accompanies each Regency UL TIMA TE Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on the right side door panel. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a diff[...]
-
Page 5
5 Regency U41-3 UL TIMA TE Gas Fireplace Insert REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chap ter 10 (2) Revise 10.8. 3 by adding the following a dditional requi rements: (a) For all side wall hor izontally ve nted gas fueled e quipment insta lled in every dwelling, bui lding or str ucture used in whole or in part for residential pu rposes, in[...]
-
Page 6
6 Regency U41-3 UL TIMA TE Gas Fireplace Insert If the factory built fi replace height is too low for your Insert, you may remove the smoke shelf, baffl e plate, and damper plate from the factory built fi replace if removable without cutting or torching, as long as these items are saved and are re-installed in the event that the Insert is remove[...]
-
Page 7
7 Regency U41-3 UL TIMA TE Gas Fireplace Insert MA TERIALS REQUIRED No electrical power supply is required for the gas control to operate. A 120 V olt AC power cord is hooked up to the fan switch and blower . Plug 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circumstances. When connected with 120 volts, the a[...]
-
Page 8
8 Regency U41-3 UL TIMA TE Gas Fireplace Insert HIGH ELEV A TION This unit is approved in Canada for altitude 2000 ft. to 4500 ft. (CAN/CGA- 2.17-M91) with the orifi ce kit Part # 611-975. For Natural Gas installations above 4500 ft. follow current CAN/CGA-B149.1. In U.S.A., for installations above 2000 ft. refer to current ANSI Z223.1 Sc8-8.1.2a [...]
-
Page 9
9 Regency U41-3 UL TIMA TE Gas Fireplace Insert Draft Hood Flue guides screw holes S pill T ube Rear S pill T ube Front INST ALLA TION 1) If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry fi replace and have the chimney swept. GAS CONNECTION For minimum and maximum supply pressure see the System Data[...]
-
Page 10
10 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION Before installing vent system ensure that the damper plate is locked into the open position and secure to prevent the damper plate from falling down and crushing the liner . GAS PRESSURE TEST The unit is preset to give the correct gas input at the specifi ed manifold pressures shown o[...]
-
Page 11
11 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION T abs Screws Right Side To p Hinged Louvers 3) Using the trim clips provided, join the left side gold trim (the one with the ON/OFF switch and variable speed F AN switch) to the top gold trim. See diagram 2. Repeat this step for right side. 8) Fan Switch wires : Connect the plug end fr[...]
-
Page 12
12 Regency U41-3 UL TIMA TE Gas Fireplace Insert DOOR INST ALLA TION (Packaged Separately) 1) Open the two side doors. 2) Slide the door onto the two hinge pins mak- ing sure the two pieces are fl ush together . See diagram 1. Diagram 1 Diagram 3 Diagram 2 Diagram 4 Diagram 2 Diagram 1 Diagram 3 LOG INST ALLA TION Note: Do not force logs down. INS[...]
-
Page 13
13 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION Thermostat Wire T able OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams on page 13. Use table on this page to determine the maximum wire length: Note: Preferable if the thermostat is installed on an interior wall. R[...]
-
Page 14
14 Regency U41-3 UL TIMA TE Gas Fireplace Insert WIRING DIAGRAM This heater does not require a 120V A.C. sup- ply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However , a 120V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires[...]
-
Page 15
15 Regency U41-3 UL TIMA TE Gas Fireplace Insert OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure t[...]
-
Page 16
16 Regency U41-3 UL TIMA TE Gas Fireplace Insert COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS A ) This appliance has a pilot which must be lighted by hand, following the instructions below exactly. B ) BEFORE LIGHTING smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier th[...]
-
Page 17
17 Regency U41-3 UL TIMA TE Gas Fireplace Insert MAINTENANCE NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating [...]
-
Page 18
18 Regency U41-3 UL TIMA TE Gas Fireplace Insert Installing Glass 1) Install both center and side glass onto extru- sions as per diagram. 2) Place glass assembly into door frame. 3) Install retainers by placing 1 drop of glue where previously glued and put in place. 4) Install side retainers. 5) Install door catch plate. 6) Install the 24 nuts loos[...]
-
Page 19
19 Regency U41-3 UL TIMA TE Gas Fireplace Insert MAINTENANCE CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. F AN MAINTENANCE 1) Unplug or disconnect power source to stove. 2) Remove all logs and the rear log support, then remove the 6 screws holding the ac- cess pan[...]
-
Page 20
20 Regency U41-3 UL TIMA TE Gas Fireplace Insert P ARTS LIST MAIN ASSEMBL Y Part # Description Part # Description 23) 710-028 Faceplate Mounting Bracket 24) 948-241 Door Latch 25) 910-325 Spill Switch 26) 610-576 False T op Assembly 836-220 False T op Insulation 27) 910-142 Thermodisc - Fan Auto/On/Of f 28) * Thermodisc Bracket 30) 610-175 Rear Pan[...]
-
Page 21
21 Regency U41-3 UL TIMA TE Gas Fireplace Insert P ARTS LIST BURNER & LOGS Part # Description 52) 910-190 Piezo Ignitor and nut 56) 910-426 Knob - Flame Hi/Low Extension 613-524/P V alve Assembly -NG 613-526/P V alve Assembly - LP 60) 910-028 V alve - RS - NG 910-029 V alve - RS - LP 904-688 Orifi ce - #32 NG 904-641 Orifi ce - #50 LP 71) * L[...]
-
Page 22
22 Regency U41-3 UL TIMA TE Gas Fireplace Insert F ACEPLA TE & TRIM Part # Description Part # Description 103) * Faceplate - Extra Oversize - Side Left Assy 613-538 Trim Pkg. - Extra Oversize -Black 104) * T rim - Extra Oversize - Right 105) * T rim - Extra Oversize - T op 106) * T rim - Extra Oversize - Left 663-91 1 Zero Clearance Faceplate 6[...]
-
Page 23
23 Regency U41-3 UL TIMA TE Gas Fireplace Insert W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime wa[...]
-
Page 24
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed:[...]