Go to page of
Similar user manuals
-
Stove
Regency U39
8 pages 1.36 mb -
Stove
Regency F3100L
28 pages 2.23 mb -
Stove
Regency C34-NG2
36 pages 2.51 mb -
Stove
Regency C34-LP2
36 pages 2.51 mb -
Stove
Regency C33-LP2
24 pages 2.26 mb -
Stove
Regency U39-LP
40 pages 5.2 mb -
Stove
Regency FG37-NG
32 pages 3.12 mb -
Stove
Regency FG39-LPG
36 pages 3.26 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Regency U37-LP PROPANE, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Regency U37-LP PROPANE one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Regency U37-LP PROPANE. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Regency U37-LP PROPANE should contain:
- informations concerning technical data of Regency U37-LP PROPANE
- name of the manufacturer and a year of construction of the Regency U37-LP PROPANE item
- rules of operation, control and maintenance of the Regency U37-LP PROPANE item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Regency U37-LP PROPANE alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Regency U37-LP PROPANE, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Regency service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Regency U37-LP PROPANE.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Regency U37-LP PROPANE item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualif[...]
-
Page 2
2 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Rear Vent Direct Vent Gas Stove by FPI Fireplace Products International. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodst[...]
-
Page 3
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 3 T ABLE OF CONTENTS Page Page Louver Installation ...................................................... 2 0 Optional Wall Thermostat .......................................... 2 0 Optional Remote Control Installation ......................... 2 0 Final Check ......................[...]
-
Page 4
4 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater This is a copy of the label that accompanies each ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove. We have printed a copy of SAFETY LABEL the contents here for your review. The safety label is located on the inside of the drop down pedestal door. NOTE: Regency units are co[...]
-
Page 5
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 5 IMPORT ANT : SA VE THESE INSTRUCTIONS The ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove must be installed in accord- ance with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to deter- mine [...]
-
Page 6
6 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater COMBUSTION AND VENTILA TION AIR The combustion air from this appliance is drawn from outside the building through the outer flue. Extra provision for combustion air inside the room is not required. VENTING The Regency Direct Vent System (Horizontal Termination Kit (640-944) and th[...]
-
Page 7
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 7 INST ALLA TION EXTERIOR VENT TERMINAL LOCA TIONS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D F K H j V ertical T ermination V V ent terminal Area where terminal is not permited A Air supply outlet 24" V A G Inside corner detail [...]
-
Page 8
8 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater PLANNING YOUR VENTING INST ALLA TION INST ALLA TION IMPORTANT Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fire or other safety hazard, and will void the warranty. Be sure to check the venting and clearance t[...]
-
Page 9
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 9 INST ALLA TION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent Selkirk Amerivent R Direct VentGS R Direct-Temp TM Direct Vent 6" Pipe Length, Galvanized 90 8 4DT-6 N / A 6" Pipe Length, Bl[...]
-
Page 10
10 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater INST ALLA TION RIGID PIPE VENTING - VERTICAL TERMINA TIONS FOR BOTH RESIDENTIAL & MANUF ACTURED HOMES/MOBILE HOMES Offset to Vertical Terminations Vertical Terminations with Co-linear Flex System The shaded area in the diagram shows the allowable vertical terminations install[...]
-
Page 11
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 11 INST ALLA TION Diagram 2a HORIZONT AL INST ALLA TIONS Diagram 1 *Dia 2a & 2b: As specified in CGA B149 Instal- lation Code. Local codes or regulations may require different clearances. RESIDENTIAL AND MANUF ACTURED HOMES/ MOBILE HOMES INST ALLA TIONS You will require the foll[...]
-
Page 12
12 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater Diagram 5 Diagram 4 Below Grade Snorkel Installation If the Snorkel Termination must be in- stalled below grade, i.e. basement ap- plication, proper drainage must be pro- vided to prevent water from entering the Snorkel Termination. Refer to Dura- Vent Installation instructions f[...]
-
Page 13
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 13 Flex Liner Exhaust Flue Air Intake Co-Linear Flex Adapter with Kit# 946-563 Co-linear DV V ertical T ermination Cap # 946-529 Inner Pipe Adapter with Kit# 946-563 U37 Rigid Pipe Adaptor Part # 640-994 Outer Pipe with Kit# 946-563 o Check local codes whether a continuous length is[...]
-
Page 14
14 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater CONVERTING A CLASS-A MET AL CHIMNEY OR MASONR Y CHIMNEY T O A DIRECT VENT SYSTEM General There are two different types of direct vent conversion systems listed below. Follow the appropriate directions for your installation. A ) Through an existing factory built metal chim- ney go[...]
-
Page 15
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 15 Converting a Masonry Chimney Important: The existing masonry flue opening needs to have an area of at least a 36 sq. in. to insure proper intake/ex- haust flow. 1 ) Before cutting any holes, assemble the desired sections of black direct vent pipe to determine the center of the ma[...]
-
Page 16
16 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater INST ALLA TION Burner Orifice Conversion Kit from Natural Gas to Propane THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit # 680-969 Contains: Qty. Part # D e s c r i p t i o n 1 910-018 SIT Conversion Kit- 50% Turndown[...]
-
Page 17
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 17 INST ALLA TION AERA TION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. Natural Gas: 1/4" open Propane: 3/8" open The aeration adjustment gears are located on the right side of the burner [...]
-
Page 18
18 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater Cutout Pin Notch D)02-46 B)02-56 A)02-65 E)02-45 Bracket A)02-65 The bottom right edge of Log G)02-48 must sit snugly against the bracket Side View G)02-48 E)02-45 F)02-47 7) Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65. E)02-45[...]
-
Page 19
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 19 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disc[...]
-
Page 20
20 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length: Note: Preferable if the thermos[...]
-
Page 21
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 21 WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/ blower operation. Caution: En[...]
-
Page 22
22 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the d[...]
-
Page 23
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 23 COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS 1 ) Push in the gas control knob slightly and turn clockwise to “OFF”. Do not force. FOR YOUR SAFETY READ BEFORE LIGHTING A ) This appliance has a pilot which must be lighted by hand, following the instructions [...]
-
Page 24
24 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as[...]
-
Page 25
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 25 MAINTENANCE LA TCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fires and after glass replacement. Turn the handle on the adjustable catch to tighten or loosen the latch. GLASS REPLACEMENT Your Regency stove is supplied with [...]
-
Page 26
26 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater REMOVING VAL VE If your valve requires maintenance or replace- ment, use the following instructions: Note: Always close off the gas supply before removing the valve. 1) Open front pedestal door. You may want to put a soft cloth on the base of the unit so that when the pedestal do[...]
-
Page 27
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 27 4) Remove the two outside frame pieces by removing two screws per side. See dia- gram below. 5 ) At this point you should disconnect the gas at the valve. You can access it through the front now that the control panel is off, or you can access it through the rear pedestal cover p[...]
-
Page 28
28 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater P ARTS LIST 1 ) 560-920 Louver Assy - Gold 560-921 Louver Assy - Brush Nickel 560-922 Louver Assy - Black 9 ) 730-560 Relief Door Assembly 10) 730-034 Mounting Plate Gasket 11 ) 730-517/P Fan Assembly (120 V) 910-331/P Fan Motor 12) 910-794 Power Cord (120 V) 15 ) * Pedestal Asse[...]
-
Page 29
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 29 P ARTS LIST U37 BURNER & LOG ASSEMBL Y 51) 910-241 Bu rn er ON/ OF F S wi tc h (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob - Fan Control Switch 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 908-646 Control Panel Decal 57) 650-2[...]
-
Page 30
30 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater U37 DOOR ASSEMBLIES Part # Description 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) 650-920 Door Gasket Kit 105) * Ceramic Paper 106) [...]
-
Page 31
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 31 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this l[...]
-
Page 32
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: [...]