Renesas H8/3067 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Renesas H8/3067, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Renesas H8/3067 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Renesas H8/3067. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Renesas H8/3067 should contain:
- informations concerning technical data of Renesas H8/3067
- name of the manufacturer and a year of construction of the Renesas H8/3067 item
- rules of operation, control and maintenance of the Renesas H8/3067 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Renesas H8/3067 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Renesas H8/3067, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Renesas service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Renesas H8/3067.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Renesas H8/3067 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Inte rface Cable for E60 00 Emulator Renesas M icrocomput er Developm ent Enviro nment System H8 Family / H8/300 H Series REJ10J0616-0400 Revision Date: A ug. 20, 2008 Rev.4.00 HS3064BEC H61H U ser’s Manual HS3064BEC H61HE[...]

  • Page 2

    [...]

  • Page 3

    1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any[...]

  • Page 4

    [...]

  • Page 5

    I IMPORTANT INFORMATION READ FIRST • READ this user's ma nual bef ore using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to u se the user sys tem in terface cable until you fully understand its mechanism. User Syst em Interf ace Cab le: Throughout this docume nt, the term "[...]

  • Page 6

    II LIMITED WA RRANTY Renesas warrants its user syst em interfa ce cabl es to be manufactured in accordance with published specific ations and free from defects in material and/or workmanship. Renesas will repair or replace a ny user system interfac e cables determined to be defective in material and/or workmanship. User syst em interface cables are[...]

  • Page 7

    III State Law : Some states do not allo w the exclusion or limitation of implied warran ties or liability for incidental or c onsequential da mages, so the abo ve limitation or exclusion may not apply to you. This warrant y gives you s pecific legal rights, an d you may ha ve other rights which may va ry from state to state. The Warranty is Void in[...]

  • Page 8

    IV SAFETY PAGE READ FIRST • READ this user's ma nual bef ore using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to u se the user sys tem in terface cable until you fully understand its mechanism. DEFINITION OF SI GNAL WORDS This is the safety alert symb ol. It is u sed to al ert[...]

  • Page 9

    V W ARNING Observe the pr ecautions listed b elow. Failure to do so will result in a FIRE H AZARD and will damage the user system and the emul ator product or will result in PERSONAL INJURY. The USER PROGRA M will be LOST. 1. Do not repair or remodel the emul ator product by yourself for e lectric shock pre vention and quality assurance. 2. Always [...]

  • Page 10

    VI[...]

  • Page 11

    i Preface Thank you for purchasing this user s ystem in terface cable (HS3064BECH61H) for the Re nesas’ original microcomput ers H8/3048 group, H8/3052 group, H8/ 3062 group, H8/3067 group, and H8/3007 group. The HS3064BECH61H is a user system interface cable that connects th e H8/3048 group, H8/3052 group, H8/3062 group, H8/3067 group, H8/ 3007 [...]

  • Page 12

    ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User Syst em Interf ace Cable to Emulator Station ......................................... 3 2.2 Connectin[...]

  • Page 13

    1 Section 1 Configuration CAUTION Use an IC149-100- 054-B51 socket (manuf actured by YAMAICH I ELECTRONICS Co., Ltd.) for the FP-100B/ TFP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS 3064BEC H61H user sys tem interface cable for the FP-100B/ TFP-100B package. User system IC socket Cable head Screws (M2.6 x [...]

  • Page 14

    2 Table 1 list s the HS3064BEC H61H components. Pleas e make sure you have all of these components when unpacking. Table 1 HS3064BEC H61H Components No. Component Quantity Remarks 1 Cable body 1 2 Cable head 1 3 IC socket 1 For the FP-100B/TFP-100B package 4 Socket cover 1 For installi ng an FP-100B/TFP -100B-packaged MCU 5 Screws (M2.6 x 12 mm) 4 [...]

  • Page 15

    3 Section 2 Connection Procedures 2.1 Connecting User System Interfa ce Cable to Emulator Station W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user syst [...]

  • Page 16

    4 2. After making sure the directi on of the cable body connector is correct, fi rmly insert the cable body connector into the emulator s tation socket, and fas ten the emulator st ation with two C TS screw (M3 x 6 mm) (figure 2). E6000 Emulator station User system interface cable Cable body connector CTS screws (M3 x 6 mm) Figure 2 Connecting User[...]

  • Page 17

    5 2.2 Connecting User System Int erface Cable to User System W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damag[...]

  • Page 18

    6 2.2.3 Inserti ng Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on t he IC socket for an FP -100B/TFP-100B package on the user syst em with pin 1 on the user system interface cable h ead, and ins ert the user system interface cable head into the IC socket on the user s ystem, as shown i n figure 3. 2.2.4 Fastening C [...]

  • Page 19

    7 Fasten the user s ystem interf ace cable head to the IC socket for an FP -100B/TFP-100B package on the user syst em with the four screws (M2.6 x 12 mm; with four flat was hers) provided. Each screw should be tightened a little at a time, altern ating between screws on opposing corners. Take special care, such as manually securing the IC s ock et [...]

  • Page 20

    8 2.2.5 Fastening C able Body Connect the cable body t o the cable head. Cable body Cable head User system Remove jig Push the remove jigs. Removing Figure 4 Fastening Cable Body[...]

  • Page 21

    9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the us er system with an IC s ocket for an FP-100B/T FP-100B package (IC149-100-054-B 51: manufactured by YAMAICHI ELECTRONIC S Co., Ltd.). Note that the dimensions in figure 5 are s omewhat different from those of t he[...]

  • Page 22

    10 2.4 Dimensions for User Syst em Interface Cable Head The dimensions for the user s ystem interf ace cable head are shown in figure 6. Unit: mm Tolerance: ±0.5 mm 66.0 76.2 23.6 18.5 29.0 29.0 Figure 6 Dimensions for User System I nterface Cable Head[...]

  • Page 23

    11 2.5 Resulting Dimensions after Conn ecting User System Interface Cable The resulting dimensions, after conn ecting the us er system interface cab le head to the user sys tem, are shown in figure 7. 29.2 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Cable head User system Unit: mm Tolerance: ±0.5 mm 16.0 Figure 7 R[...]

  • Page 24

    12 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdr iver whose head matches the screw head. 3. The tightening torque must be 0.294 N•m or less. If the applied torque ca nnot be accurately measured, stop tightening when th e force required to turn t he screw bec[...]

  • Page 25

    13 MCU Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2.6 x 6 mm) with flat washers Socket cover Figure 8 Installing MCU to User System[...]

  • Page 26

    14 Section 4 Verifying Operation 1. Start up the emulator according to the pro cedures described in the H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/ 3067 Group, H8/3007 Group E6000 Emulator U ser's Manual (HS3064BEP I61HE). 2. Verify the user system interface cable conn ections by access ing the external memory and ports to check the bus s[...]

  • Page 27

    15 Section 5 Notice 1. Make sure that pin 1 on the user s ystem IC socket i s correctly aligned wit h pin 1 on the cable head before inserting t h e cable head into the us er system IC s ocket. 2. The dimensions of the recommended mount pad for t he user system IC s ocket are different from those of the MCU . 3. This user system interface cable is [...]

  • Page 28

    16 6. The P1 jumper is us ed for testing. A j umper pin is insert ed in pin 1 side. Do not remove the inserted jumper pin. CAUTION Insert the jumper pin in pin 3 side for P4 jumper when pin 10 of the MC U is not used as RESO . Otherwise the user system interface cable, the emul ator product, and the user system will be damaged. P4 31 P1 3 1 P4 jump[...]

  • Page 29

    H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.3.00, March, 2003 Rev.4.00, August 20, 2008 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Suppor t Depar tment Global Strategic [...]

  • Page 30

    Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com Refer to " http://www.renesas.com/en/network " for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) [...]

  • Page 31

    [...]

  • Page 32

    H8/3048 Group, H8/3052 Gro up, H8/3062 Group, H8/3067 Gro up, H8/3007 Group FP-100B/ TFP-100 B User System Interface Cable for E6000 Emulator User’s Manual[...]