ResMed Positive AirwAy Pressure Device S8 Auto 25 manual
- Read online or download the manual
- 23 pages
- 0.58 mb
Go to page of
Similar user manuals
-
Respiratory Product
ResMed Silent Papillon MAP Series
30 pages 3.43 mb -
Respiratory Product
ResMed MAP Series
30 pages 3.27 mb -
Respiratory Product
ResMed CPAP
34 pages 0.78 mb -
Respiratory Product
ResMed S8 Auto 25
23 pages 0.56 mb -
Respiratory Product
ResMed VPAP IV
23 pages 0.33 mb -
Respiratory Product
ResMed Mirage Quattro 61836/2
86 pages 3.12 mb -
Respiratory Product
ResMed VPAP Auto
2 pages 0.1 mb -
Respiratory Product
ResMed VPAP IV ST
23 pages 0.33 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of ResMed Positive AirwAy Pressure Device S8 Auto 25, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ResMed Positive AirwAy Pressure Device S8 Auto 25 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of ResMed Positive AirwAy Pressure Device S8 Auto 25. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of ResMed Positive AirwAy Pressure Device S8 Auto 25 should contain:
- informations concerning technical data of ResMed Positive AirwAy Pressure Device S8 Auto 25
- name of the manufacturer and a year of construction of the ResMed Positive AirwAy Pressure Device S8 Auto 25 item
- rules of operation, control and maintenance of the ResMed Positive AirwAy Pressure Device S8 Auto 25 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ResMed Positive AirwAy Pressure Device S8 Auto 25 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ResMed Positive AirwAy Pressure Device S8 Auto 25, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ResMed service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ResMed Positive AirwAy Pressure Device S8 Auto 25.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the ResMed Positive AirwAy Pressure Device S8 Auto 25 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
S8™ A uto 25 Positive Airw A y Pressure device User Guide English[...]
-
Page 2
English S8™ A uto 25 POSITIVE AIRW A Y PRESSU RE DEVICE User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA ResMed (UK) Ltd (EU Authorised Representative) 96 Milton Park Abingdon Oxfordshire OX14 4RY UK ResMed Offic[...]
-
Page 3
Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contraindications 1 A dverse Ef f ects 1 The S8 Auto 25 S ystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Masks 2 Humidifier 2 R esScan Dat a Card 2 Using the S8 Auto 25 . . . . . . . . . . . . . . .[...]
-
Page 4
1 Introduction English Introduction The S8 TM Auto 25 self adjusti ng sleep apnoea system is indicated for the treatment of obstructive sle ep apnoea (OSA) in pati ents > 30 kg . The S8 Auto 25 is in tended for home and hosp ital use. Contraindications The S8 Auto 25 is not a life support device and may stop ope rating during power failure or ce[...]
-
Page 5
2 Masks The following ResMed mask systems are recommende d for use with this device : For information on using masks, see your mask manual. For th e latest available masks, see www.resmed.co m. Humidifier If you are ex periencing dryness o f the nose, throat or mouth, the H4i heated humidifier is recommended for use with the S8 Auto 25. ! WARNING ?[...]
-
Page 6
3 Using the S8 Auto 25 English Using the S8 Auto 25 Setting up your S8 1 Connect the power cord to the socket at the rear of your S8 Auto 25. 2 Plug the other end of the powe r cord into the power outlet. 3 Connect one e nd of the air tu bing firmly onto the air outlet. 4 Connect the assembled mask system to the free end of air tubing. For informat[...]
-
Page 7
4 Attaching a H4i Humidifier The H4i humidifier attaches to th e front of the S8 Auto 25 device to pr ovide he ated humidifica tion. This device automatica lly detects the prese nce of the H4i and no othe r accessories are requi red for its use. For more information on usi ng your H4i, please refer to the H4i user guide. ! WARNING • Make sure tha[...]
-
Page 8
5 Using the S8 Auto 25 English Using the Menus The S8 Auto 25 provides a set of functi ons which are arranged in menus and submenus. Via th e LCD screen, the menus and submenus allow you to view and change the settings for a particular function. To navi gate and make selections: 1 Press or to scroll through items within a lev el. 2 Press to enter a[...]
-
Page 9
6 How to Select the Mask Type Scroll to MASK and sel ect . Press or until you see the setting you require. The following tabl e shows the setting that should be selected for each mask: How to change the EPR level (CPAP mode) Expiratory Pressure Reli ef (EPR) can be used to help ease any discomfort you may experience when breathing out during treatm[...]
-
Page 10
7 Using the S8 Auto 25 English Starting Treatment 1 Make sure the power is on. The product name is displaye d briefly on the LCD screen, then the standby (Ramp) screen appears. The key and LCD backlights also turn on. 2 Fit your mask as described in the ma sk user instructions. ! WARNING A mask should not be use d unless your S8 Auto 25 is turne d [...]
-
Page 11
8 The LCD display s a mask-fit star rating from zero to five stars. Three to five stars indicates a good fit or better. Ze ro to two stars indicates that the mask needs to be adjusted. Reminders on the S8 LCD Your clinic ian may have set your S8 Auto 25 to remind you ab out important eve nts, such as when to replace your mask, when to insert your D[...]
-
Page 12
9 Using the S8 Auto 25 English Using the Data Card If your clinician needs to review your treatment, they will ask you to use the Data Card to copy data from your S8 device and return the card to them. Copying Data onto a Data Card 1 Switch on your S8 and wait unti l you see the standby (Ramp) screen. 2 Hold the Data Card with the a rrow facing up [...]
-
Page 13
10 Traveling with the S8 Auto 25 International Us e Your S8 flow generator has an internal powe r adapter that enables it to operate in other countries. It will op erate on power supplies of 100–240V and 50–60Hz. No special adju stment is necessary, but you will require an approved p ower cord for that country. Use on an Aircraft Please consult[...]
-
Page 14
11 Cleaning and Maintenance English Cleaning and Maintenance You should regularly carry out the cleani ng and maintenance described in this section. Refer to your mask and humidifier manual s for detailed in structions regarding the care of those devices. Daily Disconnect the air tubing and hang it in a clean , dry place until next use. Weekly 1 Re[...]
-
Page 15
12 ! WARNING • Do not wash the air filter . Th e air filter is not wa shable or reusable. • The air filter co ver protects the devi ce in th e event of accidental liqu id spillage onto the de vice. Ensure the air filter and air fi lter cover are fit ted at all times. Servicing This product should be ins pected by an authorised ResMed service ce[...]
-
Page 16
13 T roubleshooting English Troubleshooting If there is a problem, try th e following suggestio ns. If the problem cannot be sol ved, contact your equi pment supplier or Re sMe d. Do not attempt to open the device. No display Insufficient air delivered fr om the S8 device Device does not st art when you b rea the int o the mask Device does not s to[...]
-
Page 17
14 Displays er ror message: Exxxx Call Service (wher e xxxx defines an er ror) Displays er ror message: HIGH LEAK!!! Adjust Mask The follo wing message is display ed on the LCD aft er you try to updat e settings or copy data to the D ata Car d: Card Error Remove Card The follo wing message is display ed on the LCD after y ou try to update the setti[...]
-
Page 18
15 T echnical Specifications English Technical Specifications Notes: • The m anufact urer reser ves t he right to c hange these s pecificat ions without notice. • Pressure may be displayed in cm H 2 0 or hP a. Operating pressure range 4 to 25 cm H 2 O Maximum single fault steady state pressure 40 cm H 2 O Pressure measurement tolerance ±0.5 cm[...]
-
Page 19
16 Symbols Which Appear On The Device Caution; Follow instruction s for use; Drip proof; Type CF equipment; Dangerous vol t age; Class II equipment; St art/Stop and mask-fit ; Manufac turer; Environmental infor mation WEEE 2002/96 /EC is a Europ ean Direct ive that re quires th e proper dis posal of elec trical an d electroni c equipment . This dev[...]
-
Page 20
17 General W arnings and Cautions English Note: At a fixed rate of supplement al oxy gen flow , the inhaled oxygen concentration varies, depending on the pressu re set tings, patient breathing pat tern, mask, point of application and leak rate . • Do not use the S8 Auto 25 if there are obvious e xternal def ects or unexplained c han ges in perfor[...]
-
Page 21
18 Guidance and Manuf actur er ’ s De claration—Electromagnetic Emis sions and Immunit y Guidance and manufactur er’ s declaration—electr omagnetic emissions The S8 A uto 25 d evice is i ntended fo r use in the elec tromagnetic en vironment spe cified belo w . T he customer or the user of the S8 device should assu re that the device is used[...]
-
Page 22
19 General W arnings and Cautions English Guidance and manufact urer’ s declar ation—electromagnetic immunity The S8 de vice is i ntended for use in the electr omagnetic en vironment sp ecified belo w . T he customer or the us er of the S8 dev ice should assure that the device is us ed in such an environment. Immun ity test IE C 6 0 6 01- 1- 2 [...]
-
Page 23
20 Limited Warranty ResMed warrants that your ResMed product shal l be free from defects in material and workmanship for the period specified below from the date o f purchase by the initial consum er. This w a rranty is not transf erable. Note: Some mod els are not av ailable in all region s. If the product fails under conditions of norm al use, Re[...]