Go to page of
Similar user manuals
-
Oxygen Equipment
ResMed 62100
1 pages 0.04 mb -
Oxygen Equipment
ResMed 2i
26 pages 0.41 mb -
Oxygen Equipment
ResMed 60623
1 pages 0.09 mb -
Oxygen Equipment
ResMed 62136
1 pages 0.09 mb -
Oxygen Equipment
ResMed 60604
1 pages 0.09 mb -
Oxygen Equipment
ResMed Stellar 100
40 pages 7.67 mb -
Oxygen Equipment
ResMed 248672
16 pages 1.31 mb -
Oxygen Equipment
ResMed 61848
84 pages 2.77 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of ResMed VPAP ST, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ResMed VPAP ST one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of ResMed VPAP ST. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of ResMed VPAP ST should contain:
- informations concerning technical data of ResMed VPAP ST
- name of the manufacturer and a year of construction of the ResMed VPAP ST item
- rules of operation, control and maintenance of the ResMed VPAP ST item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ResMed VPAP ST alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ResMed VPAP ST, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ResMed service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ResMed VPAP ST.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the ResMed VPAP ST item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Making quality of care easy Respiratory Care Solutions VP AP ™ ST NONINV ASIVE VENTILA TOR User Guide A English 368551.indb 1 4/02/2013 3:14:20 PM[...]
-
Page 2
Making quality of care easy Respiratory Care Solutions 368551.indb 2 4/02/2013 3:14:20 PM[...]
-
Page 3
English 1 English Indications for use The VPAP ST is indica ted to provide noninvas ive ventilation for pa tients weighing more than 13 kg or more than 30 kg in iVAPS mode with respirat ory insufficiency or ob structive sleep ap noea (OSA). The VPAP ST is intended for home a nd hospital u se. Contraindications Positive airwa y pressure therapy [...]
-
Page 4
2 Setup Refer to i llustration A. 1. Connect the DC pl ug of the power supply unit to the rear of the de vice. 2. Connect t he power cord to the power supply uni t. 3. Plug the othe r end of the po wer cord into the power outl et. 4. Connect o ne end of the air tubin g firmly onto the air outlet. 5. Connect t he assembled mask syste m to the fr[...]
-
Page 5
English 3 Notes: If your cli nician has enabled Sma rtStart your device wil l start automatically wh en you breathe into the mask and stop autom atically when you remove the mask. If power is i nterrupted during tre atment, the device aut omatically restarts t herapy when power is restor ed. Cleaning and maintena nce You should r egular[...]
-
Page 6
4 SD card An SD card ha s been supplied to ga ther therapy data from your device and provi de settings updates from your clini cian. When instructe d to do so, disconnect the device from th e power outlet, remove your SD card, i nsert it in the prot ective folder and s end it to your clinicia n. For more information on removing and i nserting y[...]
-
Page 7
English 5 Problem/Possible ca use Solution EPAP may b e set to o low. Talk to your cl inician a bout your settings. Device does n ot start when you b reathe into the mask Breath is not deep enough to trigger SmartS tart/Stop. Take a deep breat h in and out through th e mask. SmartStart/St op is disabled because Le ak Alert is en abled. Press St[...]
-
Page 8
6 Problem/Possible ca use Solution The patient i s using a paediatric mask with a set pressure less than 8 cm H 2 O. Disable SmartS tart/Stop. Pressure ri ses inappropriately Talking, cou ghing or breathing in an unusual manne r. Avoid talkin g with a nasal mask on, a nd breathe as normally a s possible. Mask cush ion is bu zzing aga inst the s[...]
-
Page 9
English 7 Problem/Possible ca use Solution Displays mes sage: No tube, please check your tube is connected Flow is high because air tu bing is no t connecte d prop erly. Note: The tube di sconnection check may not operate when an antibacterial filter is used. Connect the air tubing firmly at both ends. Displays mes sage: Tube blocked, please ch[...]
-
Page 10
8 General technical specifications Power supply 90W power supply unit Input range: 100– 240V, 50–60Hz, 115V, 400Hz nomin al for aircraft us e Typical power con sumption: 70W (80VA) Maximum power consumptio n: 110W (120VA) 30W power supply unit Input range: 100– 240V, 50–60Hz, 115V, 400Hz nomin al for aircraft us e Typical power con sump[...]
-
Page 11
English 9 VPAP ST technical specification s Mode pressure ranges CPAP mode Set Pressu re: 4–20 cm H 2 O S, ST, T and PAC modes IPAP: 4–25 cm H 2 O; EPAP: 2–25 cm H 2 O iVAPS mode PS: 0–23 cm H 2 O; EPAP: 2–25 cm H 2 O Maximum single fault pressu re Max imum single fa ult steady state press ure: 30 cm H 2 O—if pressur e exceeded for [...]
-
Page 12
10 Air tubing technical specifications Air tubing Material Length Inner diameter ClimateL ine heated ai r tubing Flexibl e plastic and el ectrical compone nts 2 m 15 mm ClimateLine MAX heated air tubing Flexibl e plastic and el ectrical compone nts 1.9 m 19 mm SlimLine air tu bing Flexible plastic 1.8 m 15 mm Standard air tubing Flexible pl ast[...]
-
Page 13
English 11 Humidifier performance The following sett ings have been tested at 22°C ambient tempe rature: Mask press ure cm H 2 O RH output % Nominal system output AH a , BTPS b Setting 3 Setting 6 Setting 3 Setting 6 3 90 100 10 18 10 95 100 11.5 21 20 95 100 11 18 25 100 100 12 13.5 a. AH - Absolute Humidity in mg/L. b. BTPS - Body Temperatur[...]
-
Page 14
12 Displayed values Value Range Display resolu tion Pressure sen sor at air outlet Mask pressu re 4-20 cm H 2 O (CPAP); 2- 25 cm H 2 O (S, ST, T, PAC, iVAPS) 0.1 cm H 2 O Flow derived values Leak 0 – 200 L/min 1 L/min Tidal volume 0 – 4000 mL 1 mL Respiratory ra te 0 – 50 BPM 1 BPM Minute ventilatio n 0 – 30 L/min 0.1 L/min Ti 0.1 – 4[...]
-
Page 15
English 13 Pressure accuracy Maximum static pres sure variation at 10 cm H 2 O according to EN ISO 17510-1:20 09 Standard air tubing SlimLine air tubing Without H5i 9.89 cm H 2 O to 9.97 cm H 2 O 9.76 cm H 2 O to 9.87 cm H 2 O With H5i 9.82 cm H 2 O to 9.98 cm H 2 O 9.78 cm H 2 O to 9.88 cm H 2 O Maximum dynamic pr essure variation acco rding t[...]
-
Page 16
14 Direct curr ent; Lock/unloc k; China polluti on control logo 1; China pollution control logo 2; E uropean Authorised Representative; Not drip proof; Keep dry; Environmental informat ion WEEE 2002/96/EC is a European Dire ctive that requires the proper disposal of electrical and electron ic equipmen t. This devi ce should be disposed of separ[...]
-
Page 17
English 15 Product Warranty period Clip-type finger puls e sensors CPAP and bile vel device dat a modules Oximeters and CPAP and bilevel device oximeter adapters Humidifiers and h umidifier cleanable water tubs Titration c ontrol devices 1 year CPAP, bilevel and ventilation de vices (including externa l power supply uni [...]
-
Page 18
16 WARNINGS Read the ent ire manual before u sing the device. Use the device only as direc ted by your physician or h ealthcare provider . Use the devi ce only for the int ended use as describ ed in this manual. Ad vice contained in t his manual should not supersede instru ctions given by th e prescribing physici an. If you noti[...]
-
Page 19
English 17 Do not leave long lengt hs of air tubing around the top of yo ur bed. It could twist around your head or neck while you are sleepi ng. Do not use electr ically conductive o r antistati c air tubings. Do not us e the air tubing if there are any vis ible signs of dam age. Only ResMed air tubing and access ories should b[...]
-
Page 20
Making quality of care easy Respiratory Care Solutions 368551.indb 3 4/02/2013 3:14:20 PM[...]
-
Page 21
Gl ob al l ea d er s in s l ee p an d r es p ir at or y me di ci ne w w w.resmed.com Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abingdon Oxfordshire OX144RY UK. See www .resmed.com for other [...]