Rheem RSNA-B Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Rheem RSNA-B Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Rheem RSNA-B Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Rheem RSNA-B Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Rheem RSNA-B Series should contain:
- informations concerning technical data of Rheem RSNA-B Series
- name of the manufacturer and a year of construction of the Rheem RSNA-B Series item
- rules of operation, control and maintenance of the Rheem RSNA-B Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Rheem RSNA-B Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Rheem RSNA-B Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Rheem service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Rheem RSNA-B Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Rheem RSNA-B Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    FORM NO. S1 1-933 REV . 2 Supersedes Form No. S1 1-933 Rev . 1 RSNA-B SUPER HIGH EFFICIENCY 1 3-SEER SERIES NOMINAL SIZES 2-5 TONS [7 .0-1 7 .6 kW] P ACKAGE A IR C ONDITIONERS[...]

  • Page 2

    2 T ABLE OF CONTENTS Unit Features & Benefits ..............................................................................3-4 Model Identification Options ..........................................................................5 - 6 General Data RSNA-B Series ..................................................................................[...]

  • Page 3

    3 UNIT FEA TURES & BENEFITS—RSNA-B These qualit y feature s are inc luded in the Rhe em P acka ge Air Conditioner 5[...]

  • Page 4

    4 UNIT FEA TURES & BENEFITS—RSNA-B SERIES 1. All models feature Copeland ® Scroll ® compressors for maxi- mum efficiency and quiet operation. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes. 3. One-piece top with a drip lip to help keep water off of the unit sides. 4. Supply and return [...]

  • Page 5

    R S N A — B 036 J K 010 X X Factory Installed Options (See Next Page) Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat (018-030) 010 = 10 KW Resistance Heat (024-048) 015 = 15 KW Resistance Heat (036-048) Drive Package K = Direct Drive Electrical Designation J = 208-230V—1PH—60 Hz C = 208-230V—3PH—[...]

  • Page 6

    6 OPTIONS—RSNA-B SERIES Option Code Side Flow AA No Option AK x F A CT OR Y INST ALLED OPTION CODES Example: RSNA-B036JK000 XX (where XX is factory installed option) Example: No Options RSNA-B036JK000 Example: Options with Sideflow RSNA-B036JK000AK Note: Factory installed economizer is not available on these models. Instructions f or F actory Ins[...]

  • Page 7

    7 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B024JK B030JK B036CK B036JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 24,800 [7.27] 31,200 [9.14] 37,400 [10.96] 37,400 [10.96] EER/SEER 2 11.8/13 11.1/13 11.7/13 11.7/13 Nominal CFM/ARI Rated CFM [L/s] 800/800 [378/378] 1000/1000 [472/472] 1200/1200 [566/566] 1200/1200 [566/566] ARI [...]

  • Page 8

    8 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B042CK B042JK B048CK B048JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 42,500 [12.45] 42,500 [12.45] 50,500 [14.8] 50,500 [14.8] EER/SEER 2 11.5/13 11.5/13 11.6/13 11.6/13 Nominal CFM/ARI Rated CFM [L/s] 1400/1350 [661/637] 1400/1350 [661/637] 1600/1600 [755/755] 1600/1600 [755/755] AR[...]

  • Page 9

    9 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B060CK B060JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 60,000 [17.58] 60,000 [17.58] EER/SEER 2 11.1/13 11.1/13 Nominal CFM/ARI Rated CFM [L/s] 2000/1850 [897/873] 2000/1850 [897/873] ARI Net Cooling Capacity Btu [kW] 58,000 [16.99] 58,000 [16.99] Net Sensible Capacity Btu [kW] 40,56[...]

  • Page 10

    10 GENERAL DA T A—RSNA-B SERIES NO TES: 1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to  20% of nominal cfm. Units are certified [...]

  • Page 11

    11 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B024 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] DR ➀ .21 .20 .18 .21 .20 .18 .21 .20 .18 O U T D O O R D R Y B U[...]

  • Page 12

    12 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B036 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] DR ➀ .21 .20 .17 .21 .20 .17 .21 .20 .17 O U T D O O R [...]

  • Page 13

    GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B048 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] DR ➀ .20 .19 .17 .20 .19 .17 .20 .19 .17 O U T D O O R D R Y B U L B T E M P E R A T U R E °F[...]

  • Page 14

    INDOOR AIRFLO W PERFORMANCE—208 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet Coil Nominal Cooling Capacity T ons [kW] Motor Speed from Factory Motor Speed RPM 730 775 820 865 905 940 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 975 RPM 695 785 870 [...]

  • Page 15

    15 AIRFLOW PERFORMANCE—RSNA-B SERIES INDOOR AIRFLO W PERFORMANCE—230 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet Coil Blower Size/ Motor HP [W] & # of Speeds Nominal Cooling Capacity T ons [kW] Motor Speed from Factory Motor Speed 10x9 1 HP ECM (Constant CFM) RPM 76[...]

  • Page 16

    ELECTRICAL DA T A – RSNA-B SERIES Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size 16/16 20/20 Maximum Overcurrent Protection Device Size 25/25 Compressor Motor No. 1 Volts 208/230 Phase 1 HP 2 1/6 RPM 3450 Amps (RLA) 10.4/10.4 Amps (LRA) Unit Information Unit Operating Voltage Range 54/54 187-253 Condenser Motor No. 1 Volts 20[...]

  • Page 17

    B024JK No Heat — — 16/16 20/25 20/25 A10J 24.57/32.76 34.6/40.0 45/52 45/45 60/60 A05J 12.28/16.38 17.3/20.0 24/27 25/25 30/30 44/50 45/50 — — — — — 16/16 20/25 20/25 22/25 25/25 — — — RXQJ- Heater Kit Nominal kW Heater KBTU/Hr @ 208/240 V Heater Amp. @ 208/240 V Unit Min. Ckt. Ampacity @ 208/240 V Over Current Protective Device[...]

  • Page 18

    30% 2% 21% 2% 29% 2% 20% 2% CORNER WEIGHTS % OF TO T AL UNIT WEIGHT THERMOST A T WIRING ENTRANCE ELECTRICAL POWER ENTRANCE BLOWER/ EV APORA T OR ACCESS P ANEL SIDE SUPPL Y DUCT OPENING SIDE RETURN DUCT OPENING TOP COVER UNIT DIMENSIONS P A CKA GE AIR CONDITIONERS OUTDOOR F AN GRILLE AND COMPRESSOR ACCESS CONTROL ACCESS P ANEL LIQUID PRESSURE SERVIC[...]

  • Page 19

    52 7 / 16 " [1332 mm] FIL TER ACCESS P ANEL (FOR UNIT MOUNTED FIL TER ACCESSOR Y BLOWER/ EV APORA TOR ACCESS P ANEL OUTDOOR COIL PROTECTIVE GRILLE 25 5 / 16 " [643 mm] 10 3 / 16 " [259 mm] 4 3 / 4 " [121 mm] 5 1 / 16 " [129 mm] 1 1 / 8 " [28.6 mm] THERMOST A T WIRE ENTRANCE ELECTRICAL POWER ENTRANCE SIDE VIEW SIDE VIEW[...]

  • Page 20

    20 TYPICAL INST ALLA TIONS[...]

  • Page 21

    COMMON SUPPL Y/RETURN CONCENTRIC AIR DIFFUSER SUPPL Y AIR/PERFORMANCE NO TE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level for units with CFM greater than 1000 [472 L/s]. If the diffu[...]

  • Page 22

    DUCT AD APTERS RECT ANGULAR T O R OUND TRANSITIONS (DO WNFLO W) RXMC-CA03 RXMC-CA02 [ ] Designates Metric Con versions 22 ACCESSORIES[...]

  • Page 23

    [ ] Designates Metric Con versions RXRE-CAA30 (3 P osition) Provided with enthalpy control, and mixed air sensor . Settings include fully open, fully closed and adjustable mid point. RXRD-CAM1 0 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position poten- tiometer for proportioning (modulating) the amount of fresh[...]

  • Page 24

    CFM [L/s] RSNA-B 680 [321] RSNA-B 850 [401] RSNA-B 1020 [481] RSNA-B 1190 [562] RSNA-B 1275 [602] 1500 [708] 1400 [661] 1200 [566] 1000 [472] 800 [378] 1650 [779] 1540 [727] 1320 [623] 1100 [519] 880 [415] Minimum Airflow Model No. Nominal Airflow Maximum Airflow 510 [241] RSNA-B 600 [283] 660 [311] Airflow Pressure Drop, Inches W .C. [kPa] 1"[...]

  • Page 25

    DUCT AD APTER SIDEFLO W SQU ARE T O R OUND TRANSITION RXMC-B A01 Adapts the side rectangular supply and return openings to 14" [356 mm] diameter round openings. Adapters provided with same finish as unit and also provided with thermal insulation. 25 ACCESSORIES[...]

  • Page 26

    RXSG-AAA 14 (1 4" [356 mm] High) RXSG-AAA08 (8" [203 mm] High) R OOFCURB (Full P erimeter) RXSG-AAA08, RXSG-AAA 1 4 and RXSG-AAA24 for RSNA-B Series Hinged corners make for fast, easy set-up. NO T f or use with RQKA/RQLA/RQMA P acka ge Heat Pumps. [ ] Designates Metric Con versions 26 ACCESSORIES[...]

  • Page 27

    R OOFCURB (Full P erimeter) (Cont.) [ ] Designates Metric Con versions RXSG-AAA24 (24" [610 mm] High) 27 ACCESSORIES[...]

  • Page 28

    [ ] Designates Metric Con versions P A CKA GE AIR CONDITIONERS & GAS/ELECTRIC P A CKA GE UNITS R OOFCURB INST ALLA TION (Full P erimeter) OLD MODEL OLD CURB MODEL NEW MODEL TO OLD MODEL ROOFCURB AD APTER NEW MODEL P ACKA GE ONL Y 1 CABINET SIZE — ALL MODELS RSNA-B SMALL CABINET 20 SERIES RXPX-BACCA20 RXRX-BACDB20 RXPX-BACCA21 RXRX-BACDB21 RXP[...]

  • Page 29

    LIFT KIT—MODEL NO . RXML-A01 The lift kit is intended for temporary installation while the unit is being lifted into position. Kit includes 4 lift brackets. 29 ACCESSORIES[...]

  • Page 30

    W ARNING ONL Y ELECTRIC HEA TER KITS SUPPLIED BY THIS MANUF ACTURER AS DESCRIBED IN THIS PUBLICA TION HA VE BEEN DESIGNED, TESTED, AND EV ALU A TED BY A NA TIONALL Y RECOGNIZED SAFETY TESTING A GENCY FOR USE WITH THIS UNIT . USE OF ANY O THER MANUF A CTURED ELECTRIC HEA TERS INST ALLED WITHIN THIS UNIT MA Y CAUSE HAZARDOUS CONDITIONS RESUL TING IN [...]

  • Page 31

    31 WIRING SCHEMA TICS—RSNA-B SERIES[...]

  • Page 32

    32 WIRING SCHEMA TICS—RSNA-B SERIES[...]

  • Page 33

    33 WIRING SCHEMA TICS—RSNA-B SERIES[...]

  • Page 34

    34 WIRING SCHEMA TICS—RSNA-B SERIES[...]

  • Page 35

    35 WIRING SCHEMA TICS—RSNA-B SERIES[...]

  • Page 36

    36 WIRING SCHEMA TICS—RSNA-B SERIES[...]

  • Page 37

    37 NOTES[...]

  • Page 38

    38 NOTES[...]

  • Page 39

    39 NOTES[...]

  • Page 40

    Before pr oceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Pro vincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of contin uous progress and produ[...]