Go to page of
Similar user manuals
-
Uninterruptible power supply (
Riello Sentinel Pro 700
26 pages -
Uninterruptible power supply (
Riello iDialog
2 pages -
Uninterruptible power supply (
Riello Vision 1500
23 pages -
Uninterruptible power supply (
Riello SEP 1500
26 pages -
Uninterruptible power supply (
Riello Sentinel Pro 1000
26 pages -
Uninterruptible power supply (
Riello Vision Dual 1500
31 pages -
Uninterruptible power supply (
Riello Dialog Vision
164 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Riello Sentinel Pro 1000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Riello Sentinel Pro 1000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Riello Sentinel Pro 1000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Riello Sentinel Pro 1000 should contain:
- informations concerning technical data of Riello Sentinel Pro 1000
- name of the manufacturer and a year of construction of the Riello Sentinel Pro 1000 item
- rules of operation, control and maintenance of the Riello Sentinel Pro 1000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Riello Sentinel Pro 1000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Riello Sentinel Pro 1000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Riello service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Riello Sentinel Pro 1000.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Riello Sentinel Pro 1000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
[...]
-
Page 2
2 I NTRODUCTION Congratula tions on purchasing a UPS Sentinel Pro product and welcome to Riello UPS ! To us e the support service offered by Riello UPS , visit the site www.riello-ups.com The company is highl y specialised in the development and production of uninterruptible po wer supplies (UPSs). The UPSs in this series are high-qu ality products[...]
-
Page 3
3 C ONTENTS PRESENTATION 5 UPS V IEWS 6 F RONT VIEW 6 R EAR VIEW 6 D ISPLAY PANEL VIEW 8 B ATTERY B OX ( ACCESSORY NOT PROVID ED WITH UPS ) 9 R EAR VIEW 9 INSTALLATION 10 I NITIAL CONTENT CHECK 10 I NSTALLATION ENVIRONMENT 11 B ATTERY B OX INSTALLATION 11 S ETTING THE NOMINAL BATT ERY CAPACITY 11 USE [...]
-
Page 4
4 TROUBLESHOOTING 20 A LARM CODE S 22 F AULT 22 L OCK 23 TECHNICAL DATA 24 [...]
-
Page 5
5 PRESENTATION SENTINEL PRO uses ON-LINE double conversion technolog y, resulting in the highest levels of reliab ility and maximum protection for critical loads such as servers, IT applications and Voice/Data. It is possible to use one or more autonomy expans ion units known as BATTERY BOXES (optional acces sories) with the same dimensions and aes[...]
-
Page 6
6 UPS V IEWS F RONT VIEW R EAR VIEW 700VA / 1500VA model 1000VA / 1000VA ER model Display Slot for communication cards Multipurpose buttons Cooling fans ON/OFF switch Battery expansion connector RS232 communication port and contacts IEC 10A output socket USB communication port IEC 10A input plug[...]
-
Page 7
7 2200VA model 2200VA ER / 3000V A / 3000VA ER model RS232 communication port and contacts IEC 16A output socket (only for 3000VA models) USB communication port IEC 10A output socket Slot for communication cards IEC 16A input plug Cooling fans IEC 10A input plug Battery expansion connector[...]
-
Page 8
8 D ISPLAY PANEL VIEW “SEL” button (Select) Battery charge indicator “ON” button Load level indicator “STAND-BY” button Configuration area Regula tion operati on Maintenance request Mains operation Time r Battery operation Measurement display area Load powered by bypass Stand-by / alarm[...]
-
Page 9
9 B ATTERY B OX ( ACCESSORY NOT PROV IDED WITH UPS ) The BATTERY BOX is an opti onal accessory dedic ated to this range of UPSs (same dim ensions and aesthetic line). The BATTERY BOX c ontains batteries which allow the operat ing time of the uni nterruptible power supplies to be increased during extended blackouts. T he number of batteries containe[...]
-
Page 10
10 INSTALLATION I NITIAL CONTENT CHECK After opening the packaging, i t is first necessary to check the contents. The package must contain: UPS Schuko power cable - IEC 10A (IEC 16A for 3000VA models only) IEC 10A connecti on cable IEC 16A male plug (For 3000VA models only) USB cable User manual CD + Safety manual Battery expansion plug (ER version[...]
-
Page 11
11 I NSTALLATION ENVIRONMENT The UPS and the Battery Box must be installed in ve ntilat ed, clean environ ments which are sheltered from bad weather. The relative humidity in the en vironment must not exceed th e maximum values sho wn in the Technical Data table. The ambient temperature, whilst the UPS is in operation must remain between 0 and 40°[...]
-
Page 12
12 USE C ONNECTIONS AND SWITCHING ON FOR THE FIRST TIME 1) Check that there is a protection dev ice agai nst overcurrents and short circuits in the system upstream from t he UPS. The recommended protection v alue is 10A (for the 7 00VA, 1000VA and 1500VA versio ns) and 16A (for the 2200VA, 3000VA and ER versions) with a B or C trip curve. 2) Power [...]
-
Page 13
13 D ISPLAY PANEL MESSAGES This chapter describes, in detail, the vari ous information that can be displayed on th e LCD. UPS STATUS MESSAGES ICON STATUS DESCRIPTION Fixed Indicates a fault Flashing The UPS is in stand-by mode Fixed Indicates regular operatio n Fixed The UPS is operating from the mains Flashing The UPS is operating from the main s,[...]
-
Page 14
14 M EASUREMENT DISPLAY AREA It is possible to display the most important measur ements regardin g the UPS in sequence on the displ ay. When the UPS is switched-on, the disp la y shows the main voltage value. To display a different measur ement, press the “SEL” bu tton repeatedly until the des ired measurement a ppears. In the event of a fault/[...]
-
Page 15
15 C ONFIGURING THE OPERATING MODE The area of the display sh own in the figure displ ays the active operatin g mode and allo ws the user to choos e other modes dir ectly from the display panel. HOW TO PROCEED: To access the configuration area, hold down the “SEL” button for at least 3 seconds. The icon corresponding to the mode current[...]
-
Page 16
16 S OFTWARE M ONITORING AND CONTROL SOFTWARE The PowerShield 3 software guarantees effective, intuitive UPS managem ent, displaying all the most important information such as input voltage, appli ed load, battery capacity. It is also able to perform shutdown operations and send e -mails, text messages and network messages automatic ally when certa[...]
-
Page 17
17 UPS CONFIGURATION The table below illustrates all the possible co nfigurations availa ble to the user in order to best adapt the UPS to individ ual requirements. It is possible to perform thes e operations using the Upstools software. FUNCTION DESCRIPTION DEFA ULT POSSIBLE CONFIGURATIONS Output frequency Selects the nomina l output frequency Aut[...]
-
Page 18
18 FUNCTION DESCRIPTION DEFA ULT POSSIBLE CONFIGURATIONS Bypass voltage thresholds Selects the permi tted voltage range for s witching to the bypass Low: 180V High: 264V Low: 180 - 200 in 1V steps High: 250 - 264 in 1V steps Bypass v oltage threshold for ECO Selects the permi tted voltage range for operation in ECO mode Low: 200V High: 253V[...]
-
Page 19
19 C OMMUNICATION PORTS On the back of the UPS (see UPS Views ), the following communication ports are presen t: RS232 connector USB connector Expansion slot for additional communication cards RS232 CONNECTOR RS232 CONNECTOR PIN # SIGNAL NOTES 1 Programmable output *: [default: UPS in lock] (*) Opto-isolated contact max. +30Vdc / 35mA. [...]
-
Page 20
20 TROUBLESHOOTING Irregular UPS operation is most likely n ot an indication of a fault but due to simple problems or distracti on. It is therefore advisabl e to consult the table bel ow carefully as it summarises information whic h is useful for solv ing the most common problems. PROBLEM POSSIBLE CAUSE SOLUTION THE DISPLAY DOES NOT LIGHT UP ON/OFF[...]
-
Page 21
21 PROBLEM POSSIBLE CAUSE SOLUTION THE BUZZER SOUNDS CONTINUOUSLY AND THE DISPLAY SHOWS ONE OF THE FOLLOWING CODES: A54, F50, F51, F52, F55, L50, L51, L52 THE LOAD APPLIED TO THE UPS IS TOO HIGH Reduce the load to within the threshold of 100% ( or user threshold in the case of code A54 ). If the display shows a lock: remove the load and switch the [...]
-
Page 22
22 A LARM CODES Using a sophisticated se lf-diagnosis system, the UPS is able to c heck its own status and an y anomalies and/or faults which may occur during norm al operation and display them on the display panel. If there is a problem, the UPS sign als the event by showing the code and the type of active alarm on the display (FAULT and/or LOCK).[...]
-
Page 23
23 Active commands: Indicates the presence of an active remote command. CODE DESCRIPTION C01 Remote control 1 (Switch On/Off) C02 Remote control 2 (load on bypass or manual bypass command) C03 Remote control 3 (Switch On/Off) C04 Battery test in progress L OCK LOCK alerts are normall y preceded by an alarm signal and thei r scale lea ds to the [...]
-
Page 24
24 TECHNICAL DATA UPS MODELS SEP 700 SEP 1000 SEP 1000 ER SEP 1500 SEP 2200 SEP 2200 ER SEP 3000 SEP 3000 ER INPUT Nominal voltage [Vac] 220 - 230 - 240 Maximum operating voltage [Vac] 300 Nominal frequency [Hz] 50 - 60 Nominal current (1) [A] 3.3 4.5 6.5 9.5 12.5 BATTERY Recharge time (standard versions) [h] < 4h for 80% of the load Expandabi l[...]
-
Page 25
25 BATTERY BOX JSEP036-NP A- JSEP036-NPM- JSEP072-NPA- JSEP072-NPM- Nominal battery voltage [Vdc] 36Vdc 72Vdc Dimensions W x D x H [mm] 158 x 422 x 235 190 x 446 x 333 Weight [kg] 14 21 27 41 The “-” symbol replaces an al phanumeric code for i nternal use.[...]
-