Rinnai IB35ETRLC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Rinnai IB35ETRLC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Rinnai IB35ETRLC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Rinnai IB35ETRLC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Rinnai IB35ETRLC should contain:
- informations concerning technical data of Rinnai IB35ETRLC
- name of the manufacturer and a year of construction of the Rinnai IB35ETRLC item
- rules of operation, control and maintenance of the Rinnai IB35ETRLC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Rinnai IB35ETRLC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Rinnai IB35ETRLC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Rinnai service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Rinnai IB35ETRLC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Rinnai IB35ETRLC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    IB3 5ET RN IB35ETR LC Gas Radiant S p ace Heater Owners Operation and Inst allation Manual Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not tr y to ligh t any ap plianc e. • Do not touch any electrical switch; do not use any phone in yo ur bu[...]

  • Page 2

    2 LIMITED W ARRANTY RINNAI FIREPLACE HEA TER WHA T IS COVERED? This W arranty covers any defects in materials or workmanship, subject to the terms st ated below . This Warranty extends to the original purchaser and subsequent transferees, but only while the product remains at the site of the original installation. This Warranty only extends through[...]

  • Page 3

    3 W ARNING IMPROPER INST ALLA TION, ADJUSTMENT , AL TERA TION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INST ALLA TION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INST ALLER, SER VICE AGENCY OR THE GAS SUPPLIER. Inbuilt Fire ETR Electronic Timer Remote T able of Content s Limited warranty .................[...]

  • Page 4

    4 Model: IB35ETRBN/US, IB35ETRSN/US (NG) United S tates IB35ETRBL/US, IB35ETRSL/US (Propane) United S tates Description: Freestanding radiant/convector , glass-fronted, ceramic log sp ace heater with forced convection and natural draft flue system Gas Control: Electronic control valve Burners: Ember bed flame and heat burner W arm Air Discharge: T [...]

  • Page 5

    5 7 Read these rules and the instructions carefully . Check all local codes. Failure to follow these could cause a malfunction of the heater resulting in death, serious bodily injury and/or property damage. 8 This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases[...]

  • Page 6

    6 Diagram shows minimum clearances from combustible materials qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water . 1 6 Adequate clearances for accessibility for purposes of servicing and proper operation should be provided. 1 7 Adequate clearances arou[...]

  • Page 7

    7 TECHNICAL SPECIFICA TIONS BEDDING MA TERIAL, ET CETERA. IT IS IMPERA TIVE THA T CONTROL COMP ARTMENTS, BURNERS AND CIRCULA TING AIR P ASSAGEW A Y S OF THE APPLIANCE ARE KEPT CLEAN. 34 The glass window shall be replaced as one piece as supplied by the manufacturer . See log and glass installation on page 17. 3 5 Do not substitute glass, glowing em[...]

  • Page 8

    8 A This appliance is equipped with an ignition device which automatically ignites the pilot. Do not try to light the pilot by hand B. BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T T O DO IF YOU SMELL GAS • Do not try to l[...]

  • Page 9

    9 For your convenience the controls on your new Flame Fire are situated under the cover on the top right-hand side of the fire and are accessed by simply lifting the lid. All necessary adjustments to the operation of your fire can be made with these controls. OPERA TION CONTROL P ANEL LA YOUT • TURNING ON Press the ON/OFF button to operate the un[...]

  • Page 10

    10 deactivate the LOCK press and hold the button for 3 seconds until the indicator goes off. During normal operation the LOCK may be activated and all controls, other than the OFF switch, will be locked. Deactivating the LOCK releases the controls. If the LOCK is activated while the unit is turned OFF , then all functions will be locked including t[...]

  • Page 11

    11 proceed to TIMER 2 - which is programmed in the same way - or three times to return to the clock display . This must be done within 1 minute of setting the time to lock it into the memory . The digital display will show the current time. A small indicator on the digital display will flash to show that the display has returned to the clock. After[...]

  • Page 12

    12 NOTE: Some fluorescent lights may interfere with the transmission of remote control signals, in this case changing the position from which you are operating the remote control may help. Avoid getting the remote control wet, or dropping it. The remote control works within 15 feet and an angle of 40° to the receiver on the unit. • TO REPLACE RE[...]

  • Page 13

    13 1. Flue connection and proper venting 2. W arm air distribution. 3. Adequate air supply . 4. The heater must not be installed where curtains or other combustible materials could come into contact with it. In some cases, curtains may need restraining. See below for minimum clearances required. LOCA TION • Mantles A mantle is allowable providing[...]

  • Page 14

    14 • Fireplace dimensions There are two types of installation that may be used with this heater . • Non-combustible (masonry , brick etc) fire place. • Zero clearance kit installation, for installation in combustible materials. In each case there are minimum and maximum dimension that the fire place or opening must fall within, as shown in th[...]

  • Page 15

    15 • RUN GAS SUPPL Y For pipe sizing, refer to your local gas installation codes. • PURGE SUPPL Y OF AIR AND DEBRIS All foreign materials such as filings must be purged from the gas supply , as they may cause the gas valve to malfunction. A means to measure the gas pressure immediately upstream of the supply connection to the appliance shall be[...]

  • Page 16

    16 ELECTRICAL CONNECTION There is a junction box provided at the front of the heater for the electrical connection. W ARNING: This appliance must be properly grounded for your protection against shock hazard. Connecting the power supply: Refer to the diagram opposite, 1 Open the side doors. 2 Loosen the screws holding the front panel in place. 3 Re[...]

  • Page 17

    17 The logset is packed inside the unit and the packaging must be removed prior to installing the logset in its correct position. • Open both side panels. • Remove fasteners on both sides of the top glass retainer . • Lift retainer away from unit. • Loosen screws on bottom glass retainer . • Carefully lift glass out of bottom channel. •[...]

  • Page 18

    18 • TESTING PROCEDURE T urn gas supply on and plug the unit into the power supply . (Caution 1 15V) • TO CHECK BURNER PRESSURE • Refer to rating plate. • Remove the wiring cover panel. • Remove test point plug and attach manometer to test point. The test point is on the front injector block. • Light heater , turn to High heat setting a[...]

  • Page 19

    19 IMPORT ANT MAINTENANCE INSTRUCTIONS ANNUAL INSPECTION The unit should be inspected at least once a year by a qualified service technician including inspection of the flue system. The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids. • CLEANING INSTRUCTIONS. Before cleaning, [...]

  • Page 20

    20 • ELECTRIC MOTOR MAINTENANCE Motors are permanently lubricated and need no lubrication. Keep fan and motor free of dust and dirt, clean annually . The heater should be serviced annually only by an authorised person. • GLASS REPLACEMENT AND CLEANING . (May be performed by the owner) It is best to handle the glass with clean gloves to avoid sm[...]

  • Page 21

    21 WIRING DIAGRAM PCB LA YOUT Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing.[...]

  • Page 22

    22 NOTE: If you have any other faults or problems, please refer to your Installer or local qualified service agency WIRING DIAGRAM-LADDER SYMPT OM CA US E SOLUT I O N N o power pr es ent Ens ur e power c or d i s pl ugged i n and t ur ned on N o gas pr es ent Ens ur e gas s uppl y i s t ur ned on power c ut Re- i gni t e af t er power i s r es t or[...]

  • Page 23

    23 Er ror code Pr oba bl e ca us e C omm e n ts 11 I g n i ti o n fa i lu re C h eck gas i s t u rn e d on . Se r v i ce cal l i f r epeat ed 12 Fl ame f ai l u r e C h eck gas i s t u rn e d on . Se r v i ce cal l i f r epeat ed 14 O v erh eat Se r v i ce cal l 16 R oom ov erh eat Low er r om t em per au re t o l ess t h an 1 04° F 31 Ser v i ce [...]

  • Page 24

    24 EXPLODED DIAGRAMS[...]

  • Page 25

    25[...]

  • Page 26

    26 PARTS LIST ITEM NO. QTY. PART NO. 1 1 7993-1 FLUE SPIGOT ASSY NAT IB USA 2 1 7074 H EAT EX C HANGER FRONT ASSY 3+3H 3 1 7075 H EAT EXCH ANGER R EAR ASSY 3H 4 6 6624 BURNE R EX CHANGER TRANSFER T U BE 5 2 6625 BURNE R HEAT EXCHANGER BRACKET 6 1 7927 C O MB C H A M B ASSY IB ETR USA PAI 7 1 7616V FRON T P A NEL IB 35E TR V IPER BLACK 1 7616SP FRO [...]

  • Page 27

    27 5 3 1 7 9 2 0 FR O N T P IL O T S H IE L D U S A P AIN TE D 54 1 5327G BRA ND BA DGE GO LD 55 1 4 99 3 G A S CO NT RO L A SS Y NG US I B 35 E T R NG 1 4994 G A S CONT RO L A SSY LP US I B35ET R LP 57 2 6308 O R I N G M A I N G A S 58 2 6313 GA S T U BE R E T A I N E R 59 1 7536 R E CE I V E R U NI T E T R - 015X0 1 60 1 7537 R E CE I V E R U NI [...]

  • Page 28

    28 INST ALLA TION NOTES[...]

  • Page 29

    29 INST ALLA TION NOTES[...]

  • Page 30

    30 INST ALLA TION NOTES[...]

  • Page 31

    31 Company name: _______________________________________________________ Installers name: ______________________________________________________ Address: ______________________________________________________ ______________________________________________________ Phone: __________________ Mobile: ___________________ Permit number for installation:_[...]

  • Page 32

    Part Number 7919B zx[...]