Go to page of
Similar user manuals
-
Ventilation Hood
Roper REX3614K
1 pages 0.05 mb -
Washer
Roper SP W10200825A
20 pages 0.46 mb -
Range
Roper FGP315Y
24 pages 1.23 mb -
Clothes Dryer
Roper GL5030V
12 pages 0.94 mb -
Dishwasher
Roper Dishwasher
7 pages 0.6 mb -
Ventilation Hood
Roper REX4635E
1 pages 0.05 mb -
Clothes Dryer
Roper RGD4300S
1 pages 0.19 mb -
Range
Roper FEP330K
1 pages 0.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Roper llc-200, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Roper llc-200 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Roper llc-200. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Roper llc-200 should contain:
- informations concerning technical data of Roper llc-200
- name of the manufacturer and a year of construction of the Roper llc-200 item
- rules of operation, control and maintenance of the Roper llc-200 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Roper llc-200 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Roper llc-200, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Roper service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Roper llc-200.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Roper llc-200 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
4411-0068 Version 1.A December 10, 1997 [...]
-
Page 2
[...]
-
Page 3
iii Table of Contents Model IIC-200 Image Intensifier Controller ........................................................ 5 Introduction ......................................................................................................................... 5 Dangers and Warnings ....................................................................[...]
-
Page 4
iv Model IIC-200 Operation Manual Version 1.A This page intentionally left blank.[...]
-
Page 5
5 Model IIC-200 Image Intensifier Controller Introduct ion The IIC-200 is a stand-alone image intensifier controller. It supplies high-voltage DC bias for Princeton Instruments image intensifiers plus circuitry to facilitate gating. Gating pulses are provided by a Princeton Instruments high voltage pulser. The IIC-200 allows front-panel control of [...]
-
Page 6
6 Model IIC-200 Operation Manual Version 1.A The IIC-200 allows both Shutter and Gated modes of operation. Gating pulses can range from 5 nsec to DC. Longer gate experiments can also use the 5 volt logic electronic shutter control. Danger s and Warnings Voltages inside the IIC-200 may exceed 10,000 volts. To avoid possible hazard to personnel, use [...]
-
Page 7
Version 1.A Model IIC-200 Operation Manual 7 Note: The Model IIC-200 has automatic circuitry to help prevent damage. However, it is far better not to place an expensive intensifier at risk than to depend on the protection circuitry. Features Independently variable MCP power supply, independent of phosphor voltage. Automatic alarm and shutdown in ca[...]
-
Page 8
8 Model IIC-200 Operation Manual Version 1.A Front Pane l Feature s MCP GA IN: This adjustment is used to control the gain of the MCP by controlling the voltage across it. Display units are arbitrary. SHUTTER/GATE: This switch selects between Gate mode or Shutter mode. In Gate mode, the intensifier is normally off and a high-voltage gate pulse is n[...]
-
Page 9
Version 1.A Model IIC-200 Operation Manual 9 The plug on the line cord supplied with the system should be compatible with the line-voltage outlets in common use in the region to which the system is shipped. If the line cord plug should prove to be incompatible, a compatible plug should be installed, taking care to maintain the proper polarity to pr[...]
-
Page 10
10 Model IIC-200 Operation Manual Version 1.A Hardware O verview The IIC-200 consists of a printed circuit board and a modular high voltage supply which are mounted in a stand-alone chassis. The IIC-200 contains circuitry for the following functions: A variable high voltage power supply for the MCP voltage. The MCP voltage is a linear function of t[...]
-
Page 11
Version 1.A Model IIC-200 Operation Manual 11 Shutter circuitry which allows an electrically isolated logic signal to control the voltage between the Photocathode and MCP In. This allows long gate times or C W operation. Operatio n ➧ Review the Danger and Warning notices on page 6 before operating the IIC-200. ➧ Set the IIC-200 Power switch to [...]
-
Page 12
12 Model IIC-200 Operation Manual Version 1.A Connections with a Gen IV I ntensi fi er ➧ Connect one end of the high-voltage cable supplied by Roper Scientific to the high-voltage connector on the image intensifier. If you have purchased more than one image intensifier, make sure you are using the cable supplied with this intensifier. The connect[...]
-
Page 13
Version 1.A Model IIC-200 Operation Manual 13 Power Up Steps ➧ Make sure the front-panel MCP Power switch is O ff. Adjust MCP G ain to minimum and turn on the chassis power. Note: As long as the image intensifier and IIC-200 are purchased from Roper Scientific as part of the same order, the upper limit circuit will be set for the maximum safe lim[...]
-
Page 14
14 Model IIC-200 Operation Manual Version 1.A Scientific highly recommends updating old units at the user’s earliest convenience. Contact the factory for details. Connecting the wrong cable at both ends can result in non-functioning of the image intensifier. If you suspect that you may be using the wrong cable for your intensifier, contact the fa[...]
-
Page 15
15 Warranty & Service Warranty This equipment is warranted to be free from defects of material and workmanship. It is sold subject to the mutual agreement that the liability of Roper Scientific is limited to replacing defective parts and/or repairing malfunctioning equipment at its factory, provided the equipment is returned, transportation pre[...]
-
Page 16
16 Model IIC-200 Operation Manual Version 1.A Con tact Informatio n Roper Scientific’s manufacturing facility is located at the following address: Roper Scientific 3660 Quakerbridge Road Trenton, NJ 08619 (USA) Tel: 609-587-9797 Fax: 609-587-1970 Tech Support E-mail: techsupport@roperscientific.com For technical support and service outside the Un[...]
-
Page 17
17 Index Alarm circuit, 10 Audio beeper, 7 Auto Bright Co ntrol switch, 8 Auto Bright ness C ontrol, 7, 10 Beeper, 7 Bias levels MCP-In, 7 MCP-Out, 7 phosphor, 7 Brightnes s control, 7, 10 Contact informat ion, 16 e-mail address, 16 street address, 16 teelphone and fax numbers, 16 web site, 16 CW mod e, 7 CW operation (Gen IV), 12 Fuses, 9 Gain red[...]
-
Page 18
18 Model IIC-200 Operation Manual Version 1.A This page intentionally left blank.[...]