Go to page of
Similar user manuals
-
Refrigerator
Samsung SR-37NMB
18 pages 2.32 mb -
Refrigerator
Samsung RT2AS
24 pages 24.46 mb -
Refrigerator
Samsung RH25H5611BC
1 pages 0.05 mb -
Refrigerator
Samsung SRS536NP
16 pages 0.72 mb -
Refrigerator
Samsung RSE8F
38 pages 4.24 mb -
Refrigerator
Samsung RS21HN
44 pages 6.21 mb -
Refrigerator
Samsung RL41HGIH1
40 pages -
Refrigerator
Samsung RSG5F**
17 pages 3.93 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Samsung RS2621, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Samsung RS2621 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Samsung RS2621. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Samsung RS2621 should contain:
- informations concerning technical data of Samsung RS2621
- name of the manufacturer and a year of construction of the Samsung RS2621 item
- rules of operation, control and maintenance of the Samsung RS2621 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Samsung RS2621 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Samsung RS2621, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Samsung service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Samsung RS2621.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Samsung RS2621 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SIDE-BY-SIDE REFRIGERA T OR SAMSUNG Home Appliance Service MODEL: RS2511 RS2611 RS2630W/XAA RS2531 RS2631 RS2521 RS2621 RS2630SW[...]
-
Page 2
2 IMPOR T ANT SAFETY NO TICE The ser vice guide is f or ser vice men with adequate backg rounds of electrical, electronic, and mechanical experience. An y attempt to repair a major appliance ma y result in personal injur y and proper ty damage . The manuf acturer or dealer cannot be responsib le f or the inter pretation of this inf or mation. SAMSU[...]
-
Page 3
3 Contents 1. Saf ety instruction on ser vices ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 4 2. W arr anty inf ormation ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 9 3. Mechanical Disassemb ly ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙[...]
-
Page 4
1. Safety Instructions on Service Unplug the refrigerator before making any repair or any replacement. Avoid the electric shock. Use the rated components on the replacement. Check the correct model number, rated voltage, rated current, operating temperature and so on. On repair, be sure that the wires such as harness are bundled[...]
-
Page 5
5 2. W arranty information LIMITED W ARRANTY T O ORIGINAL PURCHASER SAMSUNG REFRIGERA T OR This SAMSUNG brand product, as supplied and distributed by Samsung Electronics America, Inc. (SAMSUNG) and delivered new, in the original carton to the original consumer purchaser, is warranted by SAMSUNG against manufacturing defects in materials and workman[...]
-
Page 6
6 3-1) Refrigerator Disassembly 3-2) Freezer Disassembly 3-3) Machine Compartment Disassembly 3. Mechanical Disassemb ly Control P anel ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 7 Door Handle ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙?[...]
-
Page 7
7 3. Mechanical Disassemb ly 1. Inser t a flat-blade scre wdriver on the slot as sho wn, and unlock the tabs . 2. Disconnect the wire connector . The door handles allow access into the refrigerator and freezer . They are front mounted with Phillips head screws . 1. With a small flat-blade scre wdriv er , press the small b utton and pull handle cov [...]
-
Page 8
8 Mechanical Disassemb ly The refrigerator light is located in the upper por tion of refrigerator . 1. Pull the tip on the cov er . These shelv es allow the stor age of larger items and pull out f or easy access . 1. Pull the shelf out as f ar as it goes . 2. Lift it up and remov e it. Dra wers are designed f or storage of fr uits , v egetab les , [...]
-
Page 9
9 Mechanical Disassemb ly Damper in the Refrigerator 1. Pull out the screw cap and remo v e the scre w . 2. Remov e the lamp co v er b y unloc king the tabs and pulling the cov er do wn. 3. Remov e the scre w at the co v er damper . 4. T ak e off sensor and lamp wire connector located on the upper liner . 6. Remov e the damper from the refrigerator[...]
-
Page 10
10 The door bins allow stor age of perishable items . 1. Push the bin up and slide it out. This s witch is located in the left-hand por tion of the freezer and sends a signal to the processor . 1. With a small flat-blade scre wdriv er , unlock the locking tabs and pull the s witch out until the wire connector is visib le. 2. Disconnect the wire con[...]
-
Page 11
11 Mechanical Disassemb ly The ice dispenser is located in the upper por tion of the freezer . This assemb ly stores ice made by the icemaker and dispenses ice . 1. Lift the ice buc k et up and slide out the ice dispenser assemb ly . The ice maker is located inside of the ice dispenser assembly . 1. Remov e ice mak er suppor t scre ws (2), [...]
-
Page 12
12 The freezer light is located in the bottom of the auger motor case. The light is co v ered b y an opaque cov er . 1. Remov e the scre w and the light co v er . The e v aporator f an is located in the middle rear of refrigerator . This fan circulates cold air in the refrigerator . 1. Remov e the f an spr ing, and than remov e f an and protector m[...]
-
Page 13
13 Ev aporator is located in the bottom of freez er to produce cold air driven across the e v apor ator coils. 1. T ak e off the ductwork in F reezer . 2. Disconnect the wire connector (Heater , Bimental, and Ther mistor). 3. Desolder the inlet and outlet tubes. 4. Remov e the e vaporator . 5. T ak e the same steps to seal the system as mentioned e[...]
-
Page 14
14 1. Disconnect the pow er cord of the refrigerator . 2. Remov e the fix ed screws (6) of compressor cov er . 3. Slide up and take off the compressor co v er to see the machine compar tment. 4. Remov e scre w (2) on the co v er . When the solenoids receiv e a signal from the micro- processor , they supply w ater to the water dispenser or the ice m[...]
-
Page 15
15 4. CIRCUIT DIA GRAM[...]
-
Page 16
16 5. OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 5-1) PO WER 5-2) OSCILLA TION CIRCUIT T erminal Oscillation F requency Vcc(DC 5V) << BLDC +12V(DC 12V) MICOM POWER AND SENSORS BLDC MOTOR POWER(NOT USE) RELAY,PANEL POWER ● When tur ned on, rectified A C v oltage which is stepped down on 2nd transf ormer flows between and at abou[...]
-
Page 17
17 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 5-3) RESET CIRCUIT 5-4) EEPROM DETECTION CIRCUIT ● RESET Circuit allows the whole program to go bac k to the initial setting by initializing par ts such as the RAM in MICOM with the power supply into MICOM or with an instant pow er f ailure. Upon the power supply , the reset terminal voltage becomes [...]
-
Page 18
18 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 5-5) DOOR SWITCH DETECT ON CIRCUIT 1) If R-Door is opened, the contact point of the door switch (4-3) becomes open, and the current of PCB line comes through R404 and R405 and provides 5 v olt which is recognized as door is opened, and tur n off the f an at diff erent load. When the door is closed, the[...]
-
Page 19
19 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 5-6) TEMP SENSING CIRCUIT 1) Sensor uses a ther mistor which has a temp coefficient of negative resistance and controls resistance. When the heat goes up , the resistance gets down and vice v ersa. R302, 4, 6, 9 and C301~C303, C305 are par ts f or noise pre v ention but the y are not related to temp se[...]
-
Page 20
20 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT T emp to Resistance of Sensor & MICOM POR T V oltage Sensor CHIP : PX41C Standard T emp . -50 °F/-45.6 °C -49 °F/-45.0 °C -48 °F/-44.4 °C -47°F/-43.9 °C -46 °F/-43.3 °C -45 °F/-42.8 °C -44 °F/-42.2 °C -43°F/-41.7 °C -42°F/-41.1 °C -41°F/-40.6 °C -40°F/-40.0 °C -39°F/-39.4[...]
-
Page 21
21 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 5-7) D AMPER CIRCUIT 5-8) DISPLA Y Cir cuit 1) The temperature of R-room is controlled by opening and closing of damper with stepping motor , supplying & bloc king cold air . 2) T A7774P (IC07) operates the damper . T A7774P is the driver IC only f or step motor . If the regular signal is provided [...]
-
Page 22
22 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 2) DISPLA Y OPERA TION Like the signal diagr am below , Micom sends “ high ” signal through MICOM 6 ter minals of NO #1 2 3 4 5 6 f or 2ms e v er y 12ms. This signal goes to output ter minal via input ter minal of IC5 (KID65783AP or TD62783AP). Output wa v e alwa ys goes through[...]
-
Page 23
23 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 5-9) Load Control Cir cuit 1) Main PCB processes most of the load control for electronic refrigerators. 2) Compressor , F-Room, defrost heater , and other functions are controlled with relay . 3) F or e xample, to operate compressor , MICOM 29 pin outputs high (5V) signal which goes into IC3 Pin #4. Th[...]
-
Page 24
24 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 1) The ice maker circuit abo v e is to control the ice maker kit installed on the F room. 2) This circuit is the hardware to control ejection and hor iz ontal positioning, ice making temperature detection and full icing detection. T emperature detection circuit is the same as temperature detection circ[...]
-
Page 25
25 OPERA TION PRINCIPLES BY P AR TS OF CIRCUIT 5-11) OPTION Circuit ● This circuit operates with the initial power on, uses DIODE (1N4148) or JUMPER WIRE. T o modify option circuit, P ower m ust be tur ned off bef ore modification and tur ned on after the modification. Ref er to the table belo w , the def ault f actor y values are highly recommen[...]
-
Page 26
39 Appendix (Ref erence f or cir cuit diagnostics) Ref .1) Measure Load T er minals LOAD TERMINALS PCB CASE V ALUE DEFECTS O THERS DISPENSER HEATER 1) DEFROST HEATER 2) ICE PIPE HEATER CN72 & CN71 & 0 0 THERMAL FUSE, HEATER, WIRE SHORT THERMAL BIMETAL, HEATER, WIRE CUT HEATER, WIRE SHORT HEATER,[...]
-
Page 27
40 Appendix (Ref erence f or cir cuit diagnostics) LOAD RELA Y TERMINALS V ALUE WHEN IT IS DIFFERENT FR OM MEASURED V ALUE DEFROST / COMP OFF RY76 /RY75 SUPPLY VOLTAGE(SV) CN71 RY75 SV CN71 COMP ON RY76 /RY75 SV CN71 RY75 0V CN71 DEFROST CUBE & AUGER MOTOR OFF CUBE & AUGER MOTOR OPERATING WATE[...]
-
Page 28
41 AD ELECTRONIC RS2 * 11 AD ELECTRONIC RS2 * 21 AD ELECTRONIC RS2 * 3 * RS2 * 11 RS2 * 21 RS2 * 31 RS2 * 30 DISPENSER LAMP 115V/60Hz 220V/50,60Hz DEF SENSOR F SENSOR R SENSOR AMBIENT SENSOR NO ITEM SPEC O THERS The second par t D A41-xxxxx? of CODE f or MAIN PCB ASS ’ Y P AR T can be changed according to MICOM or Option change, so chec k it [...]
-
Page 29
4 1. INTR ODUCTION A newl y developed SAMSUNG side b y side refrigerator in 2004 has the following characteristics. 1) T win X AirFlow Cool air circulates through side v ents on e very shelf le v el. This provides e v en distribution of cooling inside cabinets to keep y our f ood fresh longer . 2) Xtra Space TM V er tical room ne xt[...]
-
Page 30
5 2. INST ALLA TION 1) T o pr otect refrigerator in movement Use padded hand truck as shown. If entrance width is less than 39 , remov e doors prior to installation and reattach doors according to procedure below . 2) Remove all pr otective tape and pad in refrigerators. Connect water lines and po wer cord. Adjust the clearance between the door[...]
-
Page 31
6 3. Nomenc lature 2004 Models R S 26 30 SW / XAA Product ; R-SAMSUNG REFRIGERA T OR B-OEM REFRIGERA T OR Capacity ; 25,26 cu. ft F amily ; S - SIDE BY SIDE (SBS) OPTION ; 30-BEST BUY 11,21,31 ; SAMSUNG COLOR ; WW -WHITE(PCM) SH-ST AINLESS PLA TINUM SW -SNO W WHITE Buyer Code: XAA, XA C , CUR Label Location[...]
-
Page 32
Defrost Control F rom 6 to 11 hrs Defrost Ther mistor(502A T) 59 (off) Electrical Rating AC115V 60Hz 11.6 Amps Maximum Current Leakage 0.25 mA Maximum Ground P ath Resistance 0.1Ohm Energy Consumption kWh/mo . Bimetal 104 140 (off) Ambient T emper ature 70 90 Refrigerator , 34 46 34 46 F reezer , -[...]
-
Page 33
8 5. Interior Views and Dimensions 5-1) Shelves and Bins Freezer Xtra Space TM Ice Maker Door Bin Light Ice Chute Wire Shelf Drawers Front Leg Cover RS2511 ** / RS2611 ** RS2521 ** / RS2621 ** RS2531 ** / RS2631 ** Light Switch Dairy Compartment Egg Container Deli Bin Gallon Door Bins Vegetable & Fruit Drawer (upper) Vegetable & Fruit Drawe[...]
-
Page 34
9 Interior Views and Dimensions 29.5 35.6 32.2 32.1 3.4 4.4 3.4 20.1 15.2 64.5 67.9 35.8 46.2 16.4 51.2 21.4 5-2) Dimensions of Refrigerator(RS26 ** ) (Inches)[...]
-
Page 35
10 Interior Views and Dimensions 29.5 34.9 31.9 32.1 3 4.4 2.0 20.1 15.2 64.5 69.7 35.8 45.9 16.4 50.9 21.4 5-3) Dimensions of Refrigerator(RS25 ** ) (Inches)[...]
-
Page 36
11 Compressor Condenser Hot Pipe Dr y er Capillary T ube Evapor ator Suction Pipe Compressor Capillar y T ube Accumulator Ev aporator Suction Pipe Dr yer Muffler Condenser Hot Pipe Hot Pipe Compressor 6. Refrigeration Cycle and Cool Air Cir culation Route 6-1) Refrigerant Route in Refrig eration cyc le[...]
-
Page 37
12 Refrigeration Cycle and Cool Air Cir culation Route 6-2) Cool Air Circulation Freezer Refrigerator[...]
-
Page 38
13 7. Function & How- to-use By Pr oducts 7-1) DISPLA Y DESIGN RS2630SW/XAA (f or Best Buy) RS2531 ** /RS2631 ** RS2521 ** /RS2621 ** RS2511 ** /RS2611 **[...]
-
Page 39
14 1) F reez er T emp Setting 1-1) With the initial power on, F reezer will be set at MID (-4 ° F/-20 ° C) and Refrigerator will be set at MID (37 ° F/3 ° C) automatically . At this time, the number of LEDs (1 ~ 5) lighting up on the displa y panel means intensity (MIN ~ MAX) of room control temperature (6.8 ~ -13 ° F/-14 ~ -25 ° C) and as th[...]
-
Page 40
15 Function & How- to-use By Pr oducts ● When Child Lock Button on the front panel is pressed f or a cer tain per iod (3sec.), Child Lock LED gets on and all other buttons on the front panel e xcept f or Child Loc k Button do not operate. Also , Ice/W ater Dispensers do not work. (Displa y & all Ref functions will maintain the conditions [...]
-
Page 41
16 ● Among the functions depending on P eripheral T emp, Comp Cooling F an (Comp Room F an) is controlled according to P eripheral T emp as follo ws. Theref ore, mak e sure to check the contents to ref er to during A/S because Cooling F an can operate or not according to conditions dur ing Comp operation. 1) Initialization (Restoration to the ini[...]
-
Page 42
17 Function & How- to-use By Pr oducts 2) W ater Supply It is the mov ement to supply water on the ICE-TRA Y b y using the SOLENOID V AL VE after the completion of the ejection (Ejection after the completion of the nor mal ice making or that by the test mov ement) Considering cases with low hydr aulic pressure, when it is recognized as No W ate[...]
-
Page 43
18 Function & How- to-use By Pr oducts 3) Ice Making It is until the water in the ICE-TRA Y after the completion of W ater Supply gets frozen completely and the ice making mov ement is completed b y the temp of the ice making temp pickup par t using the ice maker sensor (THERMIST OR). 3-1) After water is supplied to the ICE-TRA Y , check the te[...]
-
Page 44
19 Function & How- to-use By Pr oducts 4) Ice Ejection It is the mov ement to separate the ice cubes from the ICE-TRA Y after the completion of ice making, which is conducted by the f ollo wing steps. Chec k the changes in status and time for the horizontal S/W (if it is used) and the ice le v el check S/W in parallel and then operate Ejection.[...]
-
Page 45
20 Function & How- to-use By Pr oducts 4-3) Ejection Mov ement TIMING CHAR T 5) Ice T est It is necessar y f or the f orced operation f or the pur pose of the operation test, A/S, and cleaning, and when pressing the ICE TEST S/W f or a cer tain time per iod (more than 1.5 sec.), it goes into operation. 5-1) The TEST button will not be selected [...]
-
Page 46
21 Function & How- to-use By Pr oducts 1) Button T OUCH 1-1) When selecting each button in the CONTR OL P ANEL, the v erification sound (Ding Dong) of input shall be heard. 1-2) In the case of pressing more than two KEYS at the same time or pressing the wrong button, the sound shall not be heard. 2) DOOR-OPEN 2-1) After passing 2 min. consecuti[...]
-
Page 47
22 Function & How- to-use By Pr oducts Press f or 8 sec Press f or 8 sec Press f or 8 sec RS2531 ** /RS2631 ** RS2521 ** /RS2621 ** RS2511 ** /RS2611 ** 1) F orced Operation 1-1) When pressing TEST KEY once in TEST MODE, Forced Operation shall be selected and with BEEP sound, alar m will be operated. 1-2) If F orced Operation is selected, COMP [...]
-
Page 48
23 Function & How- to-use By Pr oducts 2) F orced Defrost 2-1) When pressing TEST KET twice in TEST MODE, F reezer defrost will operate and BEEP sound alarm shall be heard. 2-2) BEEP sound alar m shall operate until the completion of HEA TING and pause. 2-3) With the selection of forced F reezer defrost, it will operate regardless of the point [...]
-
Page 49
24 Function & How- to-use By Pr oducts ● If the temp of F reez er/Refrigerator increases more than (149 ° F/ 65 ° C) in Exhibition Mode , it will restore to nor mal operation mode . ● Contents of operation in Exhibition Mode DISPLA Y , F AN MO T OR, and DISPENSER will operate normally e xcept f or Comp . and C-F AN. 7-13) SELF-DIA GNOSIS [...]
-
Page 50
25 Function & How- to-use By Pr oducts 1) Self-diagnosis with initial POWER ON 1-1) With PO WER ON, it shall diagnose the status of temp SENSOR in a minute in MICOM inter nally for itself . 1-2) If inf erior sensor is found after self-diagnosis, corresponding DISPLA Y LED will be all off at the inter val of 0.5 sec. and there will be no sound w[...]
-
Page 51
26 1) When pressing “ ICE TYPE ” and “ FIL TER RESET(LIGHT) ” KEYS sim ultaneously f or 6 sec. in normal operation, the indicators of temp set in F reez er/Refrigerator will all ON/OFF f or 2 sec. at the interval of 0.5 sec. At this point, when pressing T emp Set K e y in Refrigerator while canceling “ ICE TYPE ” and “ FIL TER RESET(L[...]
-
Page 52
27 ● When the F-Room T emp Setting b utton and the Filter Reset button or the Lighting button are pressed f or 12 seconds continuously ,the displa y will be conv er ted to the option setting mode. 7-15) OPTION SETTING NO ITEMS DISPLAY LED PROBLEM 01 02 03 04 05 06 07 08 09 Damper Condition for over load Condition for low temp COMP Freezer Defrost[...]
-
Page 53
28 1) F or e xample,,if y ou want to shift the Refrigerator STD temp by (34.7 ° F/1.5 ° C), proceed the following. It is to shift the standard temperature.The F-Room standard temp is 3 ° C(MID).When it is shifted (34.7 ° F/1.5 ° C) b y using the option,the standard temp will be set to (40.1 ° F/4.5 ° C) i.e .when the temp option is changed, [...]
-
Page 54
29 Function & How- to-use By Pr oducts APP .EX)T O DECREASE FREEZER ST AND ARD TEMP BY (-5.4 ° F/-3 ° C). Option Setting (6:(-5.4 ° F/-3 ° C)) Option CA TE. (0:F reez er Standard T emp) 1-3) If you set "10"as sho wn in the F reez er option table belo w after setting "1"to the OPTION CA TEGOR Y ,the Refrigerator standard [...]
-
Page 55
30 Function & How- to-use By Pr oducts APP .EX) T O INCREASE REFRIGERA TOR ST AND ARD TEMP BY (2.7 ° F/1.5 ° C) APP .EX) T O INCREASE REFRIGERA TOR ST AND ARD TEMP BY (2.7 ° F/1.5 ° C) Option Setting (10: 2.7 ° F/1.5 ° C) Option Cate (1:Refrigerator Standard T emp) Value- Value+ V1 V2 V3 V4 Item+ I1 I2 I3 I4 I5 Item- Option Setting (10: 2[...]
-
Page 56
31 Function & How- to-use By Pr oducts APP .EX) T O INCREASE REFRIGERA T OR ST AND ARD TEMP BY (2.7 ° F/1.5 ° C) Value- Value+ V1 V2 V3 V4 I1 I2 Item+ I3 I4 I5 Item- APP .EX)T O LO WER FREEZER ST ANDARD TEMP BY (-5.4 ° F/-3 ° C). RS2511 ** /RS2611 ** RS2511 ** /RS2611 ** Option Setting (6:(-5.4 ° F/-3 ° C)) Option CA TE. (0:F reez er Stan[...]
-
Page 57
32 Function & How- to-use By Pr oducts Note) With the F reez er button and the Lighting b utton, additional options can be set. But, those are rele vant not to the A/S b ut to the ref .control function. So , those options are skipped. (Do not change any other options e xcept the abov e options .) 1) FREEZER TEMP SHIFT T ABLE( : RELEV ANT LE[...]
-
Page 58
33 Check assembly of wires and do repairing 8. Diagnostics 8-1) When power is not supplied 1. Check if po wer is supplied at Concent and P o wer Cord is connected properly before repair 2. Check b y ref erring to the f ollowings . Is Power of primery DC -TRANS applied? Star t NO Change DC-TRANS Is Power of secondary DC - TRANS applied? NO PCB. REG1[...]
-
Page 59
1) Ambient Sensor trouble => (applied to Ambient Sensor T emp type) 34 Diagnostics 8-2) When there is a tr ouble with Self Dia gnosis Change Ambient Sensor Is Ambient Sensor normal? (PANEL PCB) Star t NO YES Connector contact trouble /re-insertion Is MAIN PCB (CN31) insertion normal? NO YES Short between connector Sensors Is the connection wire [...]
-
Page 60
35 Diagnostics Change Temp Sensor Is Freezer Temp Sensor normal? Star t NO YES Connector contact trouble /re-insertion Is the insertion of MAIN PCB connector(CN30) normal? NO YES Short between connector Sensors Is the connection between MAIN PCB connector(CN30) and Temp Sensor(yellow) normal? NO YES Check soldering fault,short, Lead Touch Is MICOM [...]
-
Page 61
36 Run Forced Operation Diagnostics 8-3) When COMP does not operat 1. If it doesnotpass5 min after a desired T emp reached, COMP does not oper ate. 2. During Defrost, COMP does not operate. 3. With the disconnected F reez er Sensor or Refrigerator Sensor , COMP does not operate because MAIN PCB picks up theT emp as a desired le v el. Is Forced Oper[...]
-
Page 62
37 MICOM voltage DOOR OPEN : 5V DOOR CLOSE : 0V Diagnostics 8-4) When F AN & D AMPER does not operate "Check out the F-F AN with the F orced Operation selected" 1. F reez er F AN, Refr igerator D AMPER and COMP COOLING F AN remains off while COMP is tur ned off . 2. When Comp is ON, Damper does not alwa ys remain ON (including F orced[...]
-
Page 63
38 Diagnostics MICOM voltage DOOR OPEN : 5V DOOR CLOSE : 0V MICOM voltage 0 V alteration 2) When Refrigerator D AMPER does not operate Forced Operation/ Temp Increase Is DAMPER in operating conditions? Star t NO YES DAMPER is normal Does DAMPER operates with DOOR S/W pressed? YES NO Change DOOR S/W Is DOOR S/W normal? NO YES Check soldering/ Ch[...]
-
Page 64
39 Diagnostics Operate Forced Operation Is COMP operating? Star t NO Stand by for FAN ON condition Confirm FAN operating condition Is it COMP COOLING FAN ON condition? NO Check soldering / Change PCB Is MICOM Pin #31 "HIGH"(5V)? NO Check soldering / Change PCB Is IC3 #17 "LOW"? NO Check Relay / Change PCB Is RELAY(RY77) normal? [...]
-
Page 65
40 COMMON RELAY RY71 Defrost Heater RY72 RELAY CHECK REFERANCE Diagnostics 8-5) When Defr ost does not operate 1. With a shor ted-out Defrost Sensor , the fridge operates normally excepting Defrost(The f ault can be pic k ed up with self-diagnosis, PO WER ON/OFF). 2. There will be Heating trouble with a shorted-out T emp FUSE, which contributes to [...]
-
Page 66
41 Diagnostics Concerned Sensor resistance measurement (Appendix TABLE) Concerned Sensor resistance measurement (Appendix TABLE) Normal Does the Function return to the normal after Heating ? YES NO Change concerned Sensor Is each concerned Defrost Sensor Temp higher than the terminated Temp? Is the input voltage of MICOM #9 higher than the voltage [...]
-
Page 67
42 MICOM Voltage #49; F-Room, #50; R-Room DOOR OPEN : 5V DOOR CLOSE : 0V Diagnostics 8-6) When Alarm Sound continues without stop 1. When Door gets open, Door Open alar m ("Ding Dong") goes off in 2 minutes with Door opened.When Door remains open after this, the alarm goes off ev ery minute. 2. When Door Switch is not pressed well, MICOM [...]
-
Page 68
43 Diagnostics 1. "Beep-Beep" sounds do not go off e xcept F orced Operation & F orced Defrost. 2. It is checckab leatP anel PCB when Forced Oper ation or F orced Defrost is selected, so when error occurs, check it andcorrect theerror . Note Re-insert Connector, Check contacts Is Connector of Upper Hinge Cover inserted well? Star t NO[...]
-
Page 69
44 Diagnostics 8-7) When Room Lamp does not light up 1. Because Room Lamp is basically controled with Door Switch, PCB does not control it. 1) When F reez er/Refrigerator Lamps do not light up Star t Check wires again Note DOOR OPEN Is DOOR OPEN? YES NO Change DOOR SWITCH Is DOOR SWITCH normal? YES NO Change LAMP Is Room LAMP(R,F) normal? YES NO[...]
-
Page 70
45 Star t Diagnostics 8-8) Dispenser Lamp Malfunction 1. Long ter m LED Shor t when e xchanging ma y result in the malfunction of PCB since Dispenser Lamp is high brightness LED . 2. When changing the PCB , the power m ust be tur ned off . Reconfirm connection wire and Lamp PCB repair/change Note Ice & water S/W push handle repair/change Is ice[...]
-
Page 71
46 Diagnostics 8-9) When W ater V alve Does Not Operate 1. While disassemb ling, make sure to cut off w ater since the water v alv e is directly connected with w ater . 2.Makesure toa v oidthe electricshock while disassemb ling because one end of wire is applied with pow er . 3.Check oper ation of water v alv e only after the w ater s witch is pres[...]
-
Page 72
47 Diagnostics 8-10) When Crush (Crushed Ice ) & Cube (Cubed Ice) does not operate well Does Ice come out when extracting Ice? Is ice in Ice Box? Is Ice Stop selected in Ice Selection? Star t Check sharp-bent/ close Water Supply Hose Check water supply part for ICE, Check Solenoid Check ICE-MAKER wires Check Ice Extraction S/W ?[...]
-
Page 73
272, Oseon-Dong, Kwangsan-Gu, Kwangju-City, Korea, 506-253 TEL : 82-62-950-6810, 6811 FAX : 82-62-950-6829 © Samsung Electronics Co., Ltd. Refrigerator Division 2004. 7 Printed in Korea Code : DA68-01369A - This Service Manual is a property of Samsung Electronics Co., Ltd. Any unauthorized use of Manual can be punished under applicable Internation[...]